285kva-cummins-diesel-generator, 285kva-cummins-diesel-generator, /cummins
Tambaya
285kva-cummins-diesel-generator, 285kva-cummins-diesel-generator, /cummins
Tambaya

matsayin kusurta na diesel na Cummins ta 285KVA

Genset mai tsoro ta yanzu 250kVA, mai tsoro a lokacin gudunmawa 285kVA da ke kuma shi ne na Cummins 6LTAA8.9-G2, 50Hz, 3-phase 400V, PF0.8, da aka amfani da ISO8528. Engine na 6-cylinder inline turbo aftercooled yana kuma shi ne da alternator na IP23 H-class mai kuskur. Canopy mai kuskur da ke ciki da system na kuma shi ne da cooling da structure na kuma shi ne da shock-absorbing, mai kuskur daga dust da rain kuma mai kuskur daga noise don tsoro na farko da tsoro a lokacin gudunmawa ga real estate, malls da wasu fabrikatun kamar kamar.

Nemi Farashi
  • Bayani

Bayani

Bayanin

Lokacin da masu ba da shawara na MEP suka tsara ƙayyadaddun ƙarfin ajiya don rukunin kasuwanci na A, asibitoci, ko wuraren cibiyar bayanai, sashin janareta yawanci yana buƙatar gwajin karɓar kaya, takaddun haƙuri na ƙarfin lantarki, da cikakkun takaddun kayan aiki. JIUAN Power 285KVA Cummins diesel janareta Model CDC285KVA, wanda ke aiki da injin Cummins 6LTAA8.9-G2 na asali an gina shi don cancanta a kowane mataki na rayuwar aikin. An ƙaddara a 250KVA prime (200KW) da 285KVA jiran aiki (228KW), wannan 250KVA mai shiru Cummins janareta yana ba da aikin da ya dace da ISO 8528 tare da ƙa'idar ƙarfin lantarki ± 1% da ƙarancin lalatawar jituwa ƙasa da 3%, yana biyan taga karɓar ingancin wutar lantarki

Mota na Cummins 6LTAA8.9-G2 wanda ke shiga wannan jenereta na diesel mai tsaro ya gina a kasar DCEC Dongfeng Cummins a cikin karama na ISO 9001, kuma kowace yanki ta da lambar ESN na faburka wanda ke iya gano a cikin tattaunawa na JIUAN Power. Tsarin na sheshi na shekara biyu — bore 114mm × stroke 145mm, displacement 8.9L, compression ratio 16.6:1 — ya daga Holset turbocharger da air-to-air aftercooler da Bosch P7100 high-pressure mechanical injection pump, wanda ya samu BSFC na 205 g/kW·h a lokacin da aka yi amfani da shi daga karshe. Cummins 6LTAA8.9-G2 zai iya sa’o wani abu daga 0% zuwa 110% na prime rating ba tare da yanci na frequency, wanda ke tabbatar da tsarin da aka bayani a cikin alamar da suka fiyakar da ayyukan masu amfani. Lokacin da aka ci gaba da cold-start ya nuna da -12°C ba tare da mabudin; amma kuma akwai wani abu da za a iya amfani da shi (jacket water heater) wanda ke tabbatar da tsoro na ignition zuwa -28°C.

Kanopya mai ƙarfi a kan wannan jenereta na diesel na Cummins da yawa ta 285KVA ana tsara shi ne daga kofin gurasa na satali da ke nufin ≥2.0mm, da aka gudan shi ne da powder coating na electrostatic wanda ya dace da 120°C, kuma aka tashin shi ne da insulation na acoustic na rock wool da ke nufin 40 kg/m³. An duba sound pressure a 7 metres kuma yana cika ɗan 65–68 dB(A), wanda ya dace da alamarin da ke cikin urban commercial-zone don installation na jenereta a gida na zazzau da a basement plant-room ba tare da acoustic treatment na musamman. Tankin fuel na base na musamman ta dace da ƙarfi na 7.5 sa’at na continuous full-load runtime, kuma abu na biyu na maintenance doors suka gaba da kula da kula da service intervals don ƙara ƙasa da 30 minutes. JIUAN Power ya saba da DSE7320 intelligent controller a cikin kowane 250KVA silent Cummins genset, wanda ya bai mu monitoring na real-time na voltage, current, frequency, oil pressure, coolant temperature, da runtime hours — da bayan ATS installation bayan da aka rufe don unattended mains-generator transfer a cikin 3–6 seconds.

Ga ƙungiyoyin masu siye da kaya inda dole ne a haɗa janareta na Cummins mai amfani da dizal 285KVA a cikin takaddun kwangila na yau da kullun, JIUAN Power yana ba da takardar shaidar garanti na shekaru 5 wanda PICC ya sanya hannu tare da kowane rukunin, yana yin rijistar ikon ɗaukar hoto da lambar serial ES Kowane CDC285KVA yana jigilar jagorar mai amfani da harsuna 5 Turanci, Larabci, Faransanci, Mutanen Espanya, Fotigal yana ba da damar ƙungiyoyin ayyukan EPC na ƙasashe da yawa don kula da raka'a a duk yankuna ba tare da goyan bayan ƙwararru ba. Ana aikawa da kayayyakin gyara na Cummins ta hanyar jigilar kaya ta iska cikin kwanaki 35 na kasuwanci. Ƙaƙarin murfin kariya na C5-M ya cika ISO 12944 don yanayin gine-ginen bakin teku; kayan aiki na sanyi jaket na ruwa mai zafi, batirin baturi, da kwantena na man shafawa na Arctic rufe kayan aiki sama da 50 ° latitude. Ana tabbatar da kaurin katako na karfe ta hanyar vernier caliper kafin aikawa, yana ƙarfafa alkawarin garanti na shekaru 5 tare da bayanan ingancin da aka rubuta.



285KVA Cummins diesel generator

Bayanan Samfuri

Paramita

Ƙima

Samfur

CDC285KVA

Kawai na wakilu

200KW / 250KVA

Kawai na kasa

228KW / 285KVA

Frequwansi / Saya

50Hz / 1500RPM; 60Hz / 1800RPM

Fasa / Kwayoyi

3-Fasa, 4-Kwayoyi

Fakar watsiya

0.8 Lagging

Tsarin injin

Cummins 6LTAA8.9-G2

Cylinders

Inline 6-cylinder

Bore × Stroke

114 × 145mm

Compression ratio

16.6:1

Tare daidaiya

Mai tsanani da kwalla

Tare daidaita

24V DC Electric Start

Madadin

Stamford / Leroy-Somer / Tooplinks

Tashar rayuwa

415/240V, 400/230V, 380/220V

Ƙungiyar rufi

Class H

Takaddun Tattara

Standard IP23; IP55 na iya zama

Matsayin Gargajiya

65–68 dB(A) @ 7m

Tsawon abu (L×W×H)

3600 × 1350 × 2000mm

Nauyi

2800 kg

Kawai

Sistemin ATS na kafa a yanki; C5-M coating; kitin na hawa mai sallama


285KVA Cummins diesel generator

Uku Uban Fasaha na Bayanin Bayani

6LTAA8.9-G2 Na'urar: ISO 8528 Kafin Tabbatacce Na Gaba da Daga Cikin Yadda Na'urar Ya Yi Amfani da 16,000 Sa’atun Da Na'urar Ya Yi Zuba

Na'urar Cummins 6LTAA8.9-G2 a cikin wannan na'urar diesel Cummins na 285KVA an tabbatacce shi a cikin ISO 8528 kafin an sanya shi a wajen ta yawa na DCEC. An yi amfani da tsari na gaba da karama daga 0% zuwa 110% na karamar asali ya nuna tsarin tashin voltage a cikin ±3% kuma tsarin tashin frequency a cikin ±1% — wanda ke kafin tabbatacce na karamar na'urar da suka iya gano a cikin amfanin na'urar. A 205 g/kW·h BSFC kuma 16,000 sa’atun da na'urar ya yi zuba, karamar amfani ya zama mafi kyau a cikin tsari na karamar da suka iya gano a cikin amfanin na'urar.

285KVA Cummins diesel generator

Takardun 5 Sa’atun da PICC Ta Tabbatacce Kuma Tsari Na ESN Don Bayani Na Karamar Na'urar

Kullum CDC285KVA yana da ƙarfin 5 shekara na PICC wanda ake bayyana shi ne da lambar tashin Cummins da kuma dukkanin alama na karamin kudin — wani kalmar da ke iya amfani da shi a siffa na masu amfani na aset da kuma masu amfani na O&M. JIUAN Power yana samun ESN da ke tsakar da shi a lokacin bauta, wanda ya haifar da imkanin gano mai sautin jenerata na diesel daga lokacin farko na amfani. Abubuwan da suka fiye da muhimmanci zasu ga kowane karamin ilimin kariya a cikin 3 zuwa 5 rabin shekara ta hanyar shugaban Cummins na JIUAN Power, wanda aka tabbatar da shi da rubutun teknikal na 5 harshen da ke bayyana karamin kafa, karamin gudunmawa, da karamin kudin na shekara farko.

285KVA Cummins diesel generator

±1% Na amfani na tashin yadda da <3% THD Na amfani na karamin kudin don abubuwan da suka zama mafi mahimmanci na gida

Stamford ko Leroy-Somer Class H brushless synchronous alternator a cikin wannan 250KVA silent Cummins genset — da ke da IP23 rating, da kuma all-copper windings da suka faduwa a vacuum — ya dace da voltage regulation na steady-state a cikin ±1% kuma total harmonic distortion a tsaki 3% a kowanne load transition. Wannan measured parameters sun dace da power quality acceptance criteria don UPS bypass commissioning tests, hospital radiology equipment, precision building automation controllers, da server room infrastructure. JIUAN Power ya rubuta kowanne 285KVA Cummins diesel generator factory power quality test results a technical data pack da aka bayar a kowanne unit.

285KVA Cummins diesel generator

Gwamnatin Amfani

CDC285KVA 285KVA Cummins diesel generator ya ke aiki ne kamar yadda ya ke taimaka wani gaba na sauyi na amariya don fuskanci na gida na sarrafa, kuma ta ke taimaka wani gaba na sauyi na amariya don hospital, hotell, kuma karamar daidai na dukkanin abubuwa da suka shiga cikin sallahin da suka shiga cikin karamar daidai na data centre UPS bypass circuits. 250KVA prime rating ya ke taimaka kuma wani gaba na sauyi na amariya don EPC construction-phase site power a Najeriyar Gabas, Najeriyar Kudu, kuma Asia Ta Tsakiya — ta zama wani gaba na sauyi na amariya bayan da aka sauya gaba na sauyi na amariya na gida.

285KVA Cummins diesel generator

Tambayoyi Masu Yawan Faruwa

S: Yaya wannan 285KVA Cummins diesel generator ya yi amfani da wani gaba na sauyi na amariya don fuskanci na gida na sarrafa?
A: Ee. Soundproof diesel generator canopy ya produce 65–68 dB(A) a 7 metres — wanda ke cikin limits da aka sani don commercial da residential zones a kowanne national environmental standards. JIUAN Power ya bayar canopy noise test certificate a kowanne order don taimaka project approval submissions.

S: DSE7320 controller a wannan 250KVA silent Cummins genset zai iya yin amfani da wani gaba na sauyi na amariya na gida BMS ko SCADA system?
A: Ee. DSE7320 yana taimaka da kwayoyin dry-contact relay da communication na RS485 Modbus, wanda ke ba da damuwa ga mafi kyakkyawan platform na BMS da SCADA domin gano halin na generator, alarmin na kuskuren, da bayanin lokacin amfani a lokacin real-time ba ta hanyar kuma converterin protocol.

matsayin kusurta na diesel na Cummins ta 285KVA

Genset mai tsoro ta yanzu 250kVA, mai tsoro a lokacin gudunmawa 285kVA da ke kuma shi ne na Cummins 6LTAA8.9-G2, 50Hz, 3-phase 400V, PF0.8, da aka amfani da ISO8528. Engine na 6-cylinder inline turbo aftercooled yana kuma shi ne da alternator na IP23 H-class mai kuskur. Canopy mai kuskur da ke ciki da system na kuma shi ne da cooling da structure na kuma shi ne da shock-absorbing, mai kuskur daga dust da rain kuma mai kuskur daga noise don tsoro na farko da tsoro a lokacin gudunmawa ga real estate, malls da wasu fabrikatun kamar kamar.

Nemi Farashi

Wanrranty da Kwalin Aiki

Matsalar Aminci

Matsalar Aminci

1 sanan ko 1000 saati

Garanti Mai Zurfi

Garanti Mai Zurfi

Za a iya samun 3 sanan don Perkins engines;
2 sanan don Stamford S-series alternators

Global After-sales

Global After-sales

Taimako na teknikal na mutumin gaskiya da shugaban kantin na kwayoyin da ke aiki

Mun faruwa da muna da gaskiya

Kariya da Sertipikit na dacewa

Kariya da Sertipikit na dacewa

Duk generator mu suka yi aiki da karamar kiyayi na kiyayi da karamar kiyayi na kiyayi: CE, ISO 9001, ISO 8528, BV, SASO, da sauran su, wanda ke nuna cewa ya dacewa da kiyayi na kiyayi da kiyayi na kiyayi da kiyayi na kiyayi na kiyayi na kiyayi.

Kariya mai zuwa da kariya mai sauƙi da kariya mai zuwa da kariya mai sauƙi

Kariya mai zuwa da kariya mai sauƙi da kariya mai zuwa da kariya mai sauƙi

Ƙarfin wutar lantarki: Daga 20kVA zuwa 5000kVA (5MW).
Matsayin: Mu ba da Open, Silent, Super-Silent, Mobile (Trailer), Containerized, da High-Voltage generator sets. Duk wani ne iya tabbatawa don yadda kuke so (yadda na tsanen, yadda na gaba, da sauransu).
Kashe da shugaban kariya

Kashe da shugaban kariya

Mun yi amfani da ƙwararren al'umma na duniya don duk abubuwan da suka fiye:
Mashin: Cummins, Perkins, Volvo, Mitsubishi, Weichai, Baudouin
Matsayin kafin daidai: Stamford, Leroy Somer
Matsayin: Deepsea, ComAp, Smartgen
Sauran da taimaka ga ayyukan

Sauran da taimaka ga ayyukan

Mai taka da ku a cikin shugaban kari:

Genset mai tabbata: ba ta ci gaba, ba ta ci gaba a cikin gida, yadda na tabbata

Takon bayani na teknoliji na kowane ayyuka da takon ganin a cikin jihadi

Ƙarin tarin aiki: takaddun data, kofin kore, kofin kwayoyi, ƙayyade

hotline na Genset na 24/7: +86 18818906850

Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China

Kuma amsa mai kyau da ƙarfi, yana da kuma tabbali.

Kunna Mana

Samu Kyautar Kyauta

Wakilinmu zai tuntube ku nan ba da jimawa ba.
Imel
Mota/WhatsApp
Sunan
Sunan Kafa
Saƙo
0/1000