1 sanan ko 1000 saati
CDS44KVA 44KVA SDEC diesel generator da ke da rating 32KW/40KVA mai yawa da 35.2KW/44KVA mai kariya, wanda ya amfani da certified SDEC 4ZT3.2-G11 four-cylinder engine. ISO8528-validated, ≤69dB(A) soundproof canopy, Class H all-copper alternator, DSE6120 controller. Ya shiga a kai tsuru — compact small business backup power don shops, clinics da field sites.
Shaguna a kan titi, asibitoci a cikin gari, da ƙananan ɗakunan aiki da ke warwatse a kasuwannin da ke tasowa suna da haɗari na gaske: katsewar wutar lantarki guda ɗaya da ba a shirya ba na iya share duk kuɗin da aka samu a rana. JIUAN Power ta tsara janareta mai amfani da dizal CDS44KVA 44KVA SDEC don magance wannan a madaidaicin sikelin darajar ƙarfin 32KW / 40KVA da ƙarfin jiran aiki 35.2KW / 44KVA, wannan ƙaramin janareta mai shiru yana farawa ta atomatik a cikin 35
A cikin wani ƙarfin da ke ƙara kuma aiki da kayan iyo mai zuwa, CDS44KVA yana da engine SDEC 4ZT3.2-G11 da aka gano, alternator mai tsakiya dukkanin copper da klasa H, da controller Deepsea DSE6120 — wadannan uku kayan iyo suna da alaƙa ta hanyar amfani da su a cikin wani abu, da aka gano su a cikin ISO8528 da GB/T2820. JIUAN Power yana nuna kowa daga wadansu genset da aka gano a cikin ISO8528 ta hanyar amfani da load aging da aka raba a cikin ƙaramin 25% zuwa 110% na load na stand-by da aka saba, kuma yana ba da documentation na output, temperature, da fuel log da za a iya gano su a cikin kowa daga wadansu delivery.
Masu amfani da karkara na yanki da masu gudumta na al'ada na ayyukan da suka zage wani maki na kudin kofa da ke cikin tsari na kudin kofa don amfani da shi a matsayin kuma don gudunmawa. SDEC 4ZT3.2-G11 engine ya nuna 212–222g/kW·h ta hanyar kudin kofa a lokacin da aka yi amfani da shi daga kowane kishin — wanda ke cikin tsoho na farko don maki na kudin kofa da ke cikin tsari na 30–50KVA. Ya ci gaba da 8 awat a lokacin da aka yi amfani da shi a 40KVA don kishin ya ci gaba da 67–72 litra daga kishin na 200L da ke cikin kishin, wanda ya kare kaya da kaya don amfani da shi a lokacin da ba suke ci gaba da kishin a lokacin da suka ci gaba da kishin.
JIUAN Power yana kirimawa kowane CDS44KVA silent diesel genset ta hanyar shiga da engine, alternator, canopy, controller, da base fuel tank masu. Wani abu ne da ke cikin waje wanda ya kamata a yi shi shine haɗawa na diesel supply da main power cable — ba wani generator room na concrete, ba wani acoustic lining na ƙasa, ba wani day tank na gaba. Wannan packaging na plug-and-go ta sa amsa mai kyau ga abubuwan da suka hada da backup power na small business a cikin Southeast Asian village retailers da Middle East infrastructure contractors. 
Paramita |
Ƙima |
Samfur |
CDS44KVA |
Kawai na wakilu |
32KW / 40KVA |
Kawai na kasa |
35.2KW / 44KVA |
Frequwansi / Saya |
50Hz / 1500rpm (60Hz / 1800rpm za a iya ziyarce) |
Fasa / Kwayoyi |
3-phase 4-wire |
Fakar watsiya |
0.8 (lagging) |
Tsarin injin |
SDEC 4ZT3.2-G11 |
Cylinders |
4 |
Bore × Stroke |
98 × 105 mm |
Compression ratio |
18 : 1 |
Tare daidaiya |
Mai tsanani da kwalla |
Tare daidaita |
24V DC Electric Start |
Istilahin alternator |
Stamford / Leroy-Somer / Tooplinks |
Ƙimar Wuta |
415/240V, 400/230V, 380/220V |
Ƙungiyar rufi |
Class H |
Takaddun Tattara |
IP23 (matsayin); IP55 yana da izinin |
Dukurun (L × W × H) |
2200 × 1000 × 1600 mm |
Nauyin aiki |
1000KG |
Ƙarfin tanki mai |
200L (tankin kuma gaba) |
Matsayin Gargajiya |
≤69 dB(A) @ 7 m |
Kama Addon |
ATS auto transfer switch; 4G remote monitoring module |

JIUAN Power yana samun abu na gurba na SDEC 4ZT3.2-G11 da shi kuma daga Shanghai SDEC, wanda shine sabon tarihin samun abu mai amfani da su a cikin duk sararin SDEC na JIUAN Power. Tsarin na uku (four-stroke) da ke cikin tsaki (in-line), da biyu na yawa (four-cylinder), da ke kula da ruwa (water-cooled), ya ba da bore×stroke ta 98×105mm, 3.2L na karamin karama (total displacement), 18:1 na karamin karama (compression ratio), da ke kula da turbin (turbocharged), da ke kula da injekshin na direk (direct injection), da ke amfani da mechanical governor a 1500RPM. Karamin karama na yawa (wet replaceable cylinder liners) yana nufin karamin karama na karama (lower overhaul cost) a lokacin da aka yi amfani da su a lokacin da aka yi amfani da su (major service intervals); karamin karama na karama (standard cold-start covers) ta zama a cikin -12°C, kuma akwai karamin karama na karama (optional oil preheater) ta zama a cikin -25°C don lokacin rana (winter-zone) da lokacin da aka yi amfani da su (highland field sites). Karamin karama na Fleetguard (Genuine Fleetguard service kit) ta zama a cikin 500-hour cycles, ta saba da B10 service life ta zama a cikin 11,500 operating hours, ta nuna cewa CDS44KVA shine karamin karama (fuel-efficient prime power generator) ta zama a cikin lokacin da aka yi amfani da su (long-haul deployment).
JIUAN Power ta tabbatar da CDS44KVA a matsayin mai ba da tabbacin ISO8528 a ƙarƙashin yanayin aiki biyu da aka bayyana a duniya. Matsayin ƙarfin farko na 40KVA (PRP) yana tallafawa ci gaba da cikakken nauyin yau da kullun na kasuwanci na yau da kullun don shagunan abinci, asibitocin gari, da ƙananan ɗakunan aiki masu aiki da yawa. Ƙididdigar ƙarfin 44KVA (ESP) yana aiki a kan rashin aiki na cibiyar sadarwa tare da 10% ƙarfin lokaci na gajeren lokaci don magance motar farawa daga ƙananan famfo da kayan aiki na iska. Matsakaicin fitarwa shine 400/230V mai matakai uku-uku-uku, 50Hz, 0.8PF; masana'antar da aka tsara 60Hz/440V fitarwa ta fitarwa ta rufe ƙayyadaddun grid na Arewacin Amurka da Afirka. 
Kanopi na karya ta hanyar tsoro wani 44KVA SDEC diesel generator ya zuba daga 2.7mm cold-rolled steel da double-layer anti-rust epoxy primer don samun yadda ya ke a cikin gida ta hanyar tsoro a karamar kusurorin da ke cikin salt-fog coastal zones, tropical monsoon regions, da dusty inland construction yards. Akwatin tsoro na multi-grade flame-retardant, duct na composite muffler, da industrial silencer na sauyi yadda ya ke a cikin gida ta hanyar tsoro don samun broadband noise a ≤69dB(A) a 7 metres — wanda ya tabbataci yadda ya ke a cikin gida ta hanyar tsoro na residential estates da commercial high streets. Kwanaki na maintenance na widened single-side da glass observation window suna ba da imkanin samun yadda ya ke a cikin gida ta hanyar tsoro ba tare da karya na kanopi.
Alternator na kwayoyin kuma na gaba ta Class H da aka futa shi ne a cikin vacuum, da ke amfani da copper mai sauƙi da kuma da bearing ɗaya, wanda ya nufi kuma yana nufi da voltage regulation ≤±1.2% kuma total harmonic distortion (THD) a matsayin 3% ko ƙasa daga wannan a cikin conditions na rated — wanda ya zama da power quality requirements na alatun tattauna na klinik, server rooms na kwayoyin kuma, da micro telecom base stations. IP23 protection don dust da moisture yana nufi da stable output a cikin damp basement installations da coastal environments. Circuit breaker na moulded-case wanda aka saba shi a factory yana nufi da layered protection don overload, short-circuit, under-voltage, overspeed, da overtemperature. 
JIUAN Power yana sanya Deepsea DSE6120 bilingual LCD controller a matsayin abu da aka sa kuma a kowace silent diesel genset a wannan shagali, wanda ya ba masu amfani damar ganin bayani na zaman lafiya ta hanyar voltage, current, lube oil pressure, coolant temperature, runtime hours, da fault codes daga wani panel. Automated start on mains loss, timed cool-down shutdown on supply restoration, da fault alarm stop suna a matsayin abu da aka sa kuma a cikin kowane genset. Bayan ATS mai gaskiya a cikin control cabinet yana iya raba transfer switch don direct mains-to-genset switching; 4G module mai zahiri yana iya taimaka wajen remote monitoring ta mobile-phone don distributed unmanned field sites. 
JIUAN Power tana fitar da janareta na CDS44KVA 44KVA SDEC na dizal a matsayin ƙaramin ƙarfin janareta mai ƙarfi zuwa asibitocin al'ummomin gari, shagunan abinci na titi, ƙananan kayan aiki da ɗakunan aiki na katako, wuraren zama na gidaje, wuraren aikin gine-gine, tashoshin Ana samun ci gaba da fitar da kayayyaki daga yankunan kudu maso gabashin Asiya, da yankunan karkara na Afirka da kuma kananan kayayyakin more rayuwa a Gabas ta Tsakiya da ke bukatar samar da wutar lantarki mai amfani da wutar lantarki a yankunan da ba su da wutar lantarki. 
Tambaya: Wace irin nauyin kaya ne CDS44KVA zai iya ɗaukarwa a cikin ƙananan asibiti ko kantin magani?
A: Klinikai suna da kuma aiki na mabuwa mai saukarwa, iluminashin alama na gudum, mota na centrifuge, da kompyuta na network. CDS44KVA na 40KVA wani yadda ya ke aiki mai sauƙi zai iya taimaka wajen wannan aiki ta hanyar 75–80% na kwayoyin aiki don aiki dayam dayam, amma mota na SDEC 4ZT3.2-G11 na 3–5 seconds na auto-start ta hanyar DSE6120 zai iya rage aiki a lokacin da ba a bincika ba. JIUAN Power ya bayyana cewa ya kamata mu duba kowane aiki na kuma a cikin kewayoyin aiki na kasa yayi amfani da assessment na kasa don sanin yadda za a saba kewayoyin aiki.
Tambaya: Shin ana buƙatar ɗakin janareta na waje don shimfidawa ko shigarwa na farfajiyar?
A: A’a. Canopy mai kare ta hanyar ISO8528 wanda aka shahara shi ya ba mu aminci na IP23 da sautin da ke ƙasa da 69dB(A), wanda ke nuna cewa yiwu ne daidai don sadarwa na wannan generator mai sauƙi da karami a gida na kwayoyi da kuma a dandano na gida na kwayoyi, a cikin kadan na al’ada na sautin da suka haɗa da al’ada na gida da kuma al’ada na kwayoyi. Tankin da ke 200L na baya da kishin da ke canopyn ya zama iya fayyade don tsayar da abinci a lokacin da ke cikin rana. Kiyun bayanin da ke cikin kwayoyi na kwayoyi ne kawai wanda ke bukatar da yadda ake sanya wannan maitatun da ke cikin gida na kwayoyi a lokacin da ke cikin kwayoyi.
CDS44KVA 44KVA SDEC diesel generator da ke da rating 32KW/40KVA mai yawa da 35.2KW/44KVA mai kariya, wanda ya amfani da certified SDEC 4ZT3.2-G11 four-cylinder engine. ISO8528-validated, ≤69dB(A) soundproof canopy, Class H all-copper alternator, DSE6120 controller. Ya shiga a kai tsuru — compact small business backup power don shops, clinics da field sites.
1 sanan ko 1000 saati
Za a iya samun 3 sanan don Perkins engines;
2 sanan don Stamford S-series alternators
Taimako na teknikal na mutumin gaskiya da shugaban kantin na kwayoyin da ke aiki
Wadanda jikin JIUAN suka bayyana — a baya da kafin su zo a kafin kafin.
Matsayin matsayin da aka sanya a cikin 2 shekara ko 2,000 awa (wanda ya gabata), da aka sanya a cikin al'ada ta PICC — wanda ya ba masu amfani daga wajen kuskure a kowane kwaye.
Saurin sauyin da kwayoyin amfani na matsayin da aka sanya — kwayoyin da suka gabata a matsayin da aka sanya ya zo daga wajen a cikin 3 zuwa 5 rana, wanda ya kare kuskuren da ake ci gaba.
Kwayoyin da suka kusanta sautin suna amfani da steel ta cold-rolled, powder coating ta high-gloss da insulation ta flame-retardant don kuskuren da rust, scratch da sautin.
Kowane kwaye shine ta farko da ESN ta musamman da ta iya tabbatarwa. Kowane generator ya kusa da tsari na full-load da overload a cikin kuskuren da aka sanya.
Kofigurashin na yankin gida, yankin kusurwar kasa da yankin da ke ciki na alama ta hanyar taimaka wajen saukin yadda, kariya da kariya a matsayin kuma kariya a matsayin.
Taimaka da amfani da shahada na kafin kafin da kafin kafin ya taimaka wajen kafin kafin daga makamantarmu zuwa kafin kafin.
Genset mai tabbata: ba ta ci gaba, ba ta ci gaba a cikin gida, yadda na tabbata
Takon bayani na teknoliji na kowane ayyuka da takon ganin a cikin jihadi
Ƙarin tarin aiki: takaddun data, kofin kore, kofin kwayoyi, ƙayyade
hotline na Genset na 24/7: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Kuma amsa mai kyau da ƙarfi, yana da kuma tabbali.