Matsalar Aminci
1 sanan ko 1000 saati
genset mai tsoro a lokacin gudunmawa 600kVA da ke kuma shi ne na Cummins KTA19-G3A engine na 6-cylinder inline, 50Hz/400V, PF0.8, da aka amfani da ISO8528. Turbo aftercooled da PT fuel system, da ke kuma shi ne da alternator na IP23 H-class mai kuskur. Canopy mai kuskur da ke ciki da cooling, damping da silencing structure, mai kuskur daga rain da dust don tsoro a lokacin gudunmawa ga mines, buildings da wasu projectin sabaqan.
Don kuma mai amfani da generator 600KVA don samun abin da ke cikin gari, tambaya mai muhimci ba shi ne bayanin teknikal — amma shi ne bayanin da za a iya tabbatarwa cewa abin da aka bayani ya yi a matsayin shi. Generator JIUAN Power 600KVA na diesel na Cummins — Model CDC600KVA, wanda ya dace da engine na Cummins KTA19-G3A mai haƙiƙi — ya zo da wasu video na test na load na farko da aka rubuta a faburka da wasu raportin PDF na analysis na load a cikin abubuwan da aka saba. Ya dace da 540KVA don yin aiki (432KW) kuma 600KVA don yin aiki a lokacin da ba ake amfani ba (480KW), wannan generator na Cummins mai tsoro na 540KVA ya bayyana output da ke da al’ada na ISO 8528 da kuma voltage regulation na ±1% kuma THD ta zama babu 3%, da suka tabbatarwa da wasu bayani na test.
Ingine na Cummins KTA19-G3A wanda ke ƙananin wannan gariya na diesel mai tsawo a cikin kwalla, ya shage a kwalla na CCEC Chongqing Cummins wanda aka sertifika da ISO 9001. Tsarin shiga na shida na 6 silinda — bore 159mm × stroke 159mm, displacement 19L, compression ratio 13.9:1 — ya daga Holset turbocharger da air-to-air aftercooler da Cummins PT high-pressure fuel injection system, wanda ya nemo yadda ya yi injekshin pressure daga zero zuwa full load ba tare da electronic control units ba, yana samun BSFC na 193 g/kW·h. Ingine na Cummins KTA19-G3A ta iya zama da staged loads daga 0% zuwa 110% na prime rating, wanda ke haɗa da protocol na test na factory wanda JIUAN Power suya a baya da kwalla. Cold-start ya ƙarfi zuwa -15°C ba tare da aids na farko ba; jacket water heater na factory-fitted ta iya rufe ignition zuwa -30°C.
Kanopi mai ƙarfi a cikin wannan jenereta na diesel na Cummins da kuma 600KVA ya ƙauna daga shayi na steel na cold-rolled wanda ke ƙarfi ≥2.0mm, da aka gaba daya da powder electrostatic a 120°C, kuma ya ƙauna da rock wool na 40 kg/m³, da yawa 65–68 dB(A) a 7 metres. Tankin base na kudin abinci wanda ke cikin jenereta ya taimaka wani lokacin ƙananu na 7 sa’at a lokacin da ke ƙara ƙananu, kuma kofin da suka biyo a cikin kofin biyu sun taimaka wani amfani na kuskure na yawa. Kowa daga wasu jenereta na Cummins wanda ke 540KVA da kuma silent suna zo da DSE7320 na controller na ayyukan aljebra a matsayin standard — da suka nuna voltage, current, frequency, oil pressure, coolant temperature, da sa’at na lokacin da ke ƙara — kuma kuma bayi na ATS wanda ke cikin jenereta da ke cikin kuskure na mains-generator a lokacin da ke ƙara 3–6 seconds a lokacin da ke ƙara kuskure na mains.
Kullin CDC600KVA 600KVA Cummins diesel generator yana samu kuma aiki na teknik: videos na test na load na factory (0%, 25%, 50%, 75%, 100%, da 110% overload), report na PDF na analysis na load, 3D rendered exploded views na engine da alternator sub-assemblies, da taswirin close-up na components don verification na anti-counterfeiting. JIUAN Power yana ba da certificate na warranty na 5 years wanda PICC ya gudan, wanda ya register ESN serial number na Cummins KTA19-G3A engine don asset records, user manual na 5 languages (English, Arabic, French, Spanish, Portuguese), electrical wiring diagrams, CD na 3D disassembly animations, da service wrenches na complimentary da testing meters. Thickness na canopy steel panel ana amfani da vernier caliper don verify a baya, kuma critical spares na air freight zasu dace su fage da kowa wajen international port a cikin 3–5 business days, wanda suka cover full 5-year warranty period.

Paramita |
Ƙima |
Samfur |
CDC600KVA |
Kawai na wakilu |
432KW / 540KVA |
Kawai na kasa |
480kw / 600kva |
Frequwansi / Saya |
50Hz / 1500RPM; 60Hz / 1800RPM |
Fasa / Kwayoyi |
3-Fasa, 4-Kwayoyi |
Fakar watsiya |
0.8 Lagging |
Tsarin injin |
Cummins KTA19-G3A |
Cylinders |
Inline 6-cylinder |
Bore × Stroke |
159 × 159mm |
Compression ratio |
13.9:1 |
Rarraba |
19L |
Tare daidaiya |
Mai tsanani da kwalla |
Tare daidaita |
24V DC Electric Start |
Madadin |
Stamford / Leroy-Somer / Tooplinks |
Tashar rayuwa |
415/240V, 400/230V, 380/220V |
Ƙungiyar rufi |
Class H |
Takaddun Tattara |
Standard IP23; IP55 na iya zama |
Matsayin Gargajiya |
65–68 dB(A) @ 7m |
Tsawon abu (L×W×H) |
4500 × 1800 × 2450mm |
Nauyi |
5800 kg |
Kawai |
Sistemin ATS na kafa a yanki; C5-M coating; kitin na hawa mai sallama |

Mota na Cummins KTA19-G3A a cikin wannan maita na diesel na Cummins na 600KVA yana amfani da sistema na injekshin na fuel na Cummins PT — wanda ya tsara ta hanyar pressure na fuel rail ba tare na electronic injection units ba — kuma yana bayyana kwalitas na combustion mai zama gaba dayi a kowanne load profile daga zero zuwa 110% overload. JIUAN Power yana rubutu da amsa video na staged load test na kowanne unit a factory. Ta hanyar 193 g/kW·h BSFC da 15,000-hour overhaul interval, platform na KTA19-G3A yana haɗawa na economy na operation da durability na documented long-term don prime da standby power applications. 
Kullum CDC600KVA yana da shahada ta 5 shekara na garawa ta PICC wanda ya kafa shahada ta Cummins engine serial number — wani doka da za a iya amfani da shi don tabbatarwa na asetin abokan so ko kuma don bayani na O&M. JIUAN Power yana tabbatarwa tsawon steel panel na canopy ta amfani da vernier caliper a baya da bayani, kuma yana ba da 3D rendered exploded views da sauransu suka fito daga cikin rukuni na anti-counterfeiting, wanda ke taimaka ga kungiyar ingantaccen tabbatarwa na haɗa na diesel generator mai gamsarwa a baya da amfani. Zai samu karamin abubuwa da suka hada a cikin 3 zuwa 5 rana na aiki a kowane mabaratin kamar yadda JIUAN Power ta sanya Cummins parts network. 
Alteneta na Stamford ko Leroy-Somer Class H mai tsanani a cikin kumminis genset na 540KVA wanda aka gudanar da shi a sako — da ke da IP23, da ke da kwayoyin copper douni na vacuum-impregnated — ya nuna amfanin voltage regulation a cikin ±1% kuma total harmonic distortion ta zama akwai ne a yadda 3% a cikin duk yadda da suka faru. C5-M corrosion-protection coating (wanda ke da izini) ta fito a ISO 12944 don yadda na kusti da offshore; cold-weather kits — jacket water heaters, battery blankets, da arctic lubricant packages — sun taimaka wani 600KVA Cummins diesel generator don yin amfanin a -30°C don yadda na high-latitude infrastructure projects. 
CDC600KVA 600KVA Cummins janareta na dizal yana aiki ne a matsayin babban iko da kuma jiran aiki don ayyukan hakar ma'adinai, asibitocin Grade A, wuraren shakatawa na masana'antu na sinadarai, cibiyoyin bayanai, tsarin taimakon tashar LNG, da manyan ayyukan gini a duk Gabas ta Ts JIUAN Power yana jigilar kowane injin diesel mai rufin sauti wanda aka riga aka haɗu, yana ba da damar haɗa wutar lantarki da igiyoyin wutar lantarki a lokacin isowa don saurin aiki. 
Tambayoyi Masu Yawan Faruwa
Tambaya: Waɗanne takardu ne ke shigowa tare da kowane umarnin janareta na Cummins 600KVA?
A: JIUAN Power yana samar da bidiyo na gwajin kaya na masana'anta (0%110%), rahoton nazarin kaya na PDF, ra'ayoyin fashewar 3D, hotunan kayan haɗin ƙirar, littafin kula da harsuna 5 na shafuka 150, zane-zane na wayoyin lantarki, CD mai motsa jiki na 3D, da maɓallan
Tambaya: Shin wannan 540KVA shiru Cummins janareta rated ga ci gaba da babban ikon amfani?
A: Ee. 540KVA na bayani mai zuwa yana ba da izini ga Cummins KTA19-G3A don aiki mai tsayi ta yamma kuma ta yamma a cikin wani lokaci. 19L na bayani mai zuwa yana tsohon aiki a cikin 80–100% kuma yana zama ba ta gaskiya don fadu na sautin hanyar aiki na maki na karami da suka dace da aiki mai zuwa.
genset mai tsoro a lokacin gudunmawa 600kVA da ke kuma shi ne na Cummins KTA19-G3A engine na 6-cylinder inline, 50Hz/400V, PF0.8, da aka amfani da ISO8528. Turbo aftercooled da PT fuel system, da ke kuma shi ne da alternator na IP23 H-class mai kuskur. Canopy mai kuskur da ke ciki da cooling, damping da silencing structure, mai kuskur daga rain da dust don tsoro a lokacin gudunmawa ga mines, buildings da wasu projectin sabaqan.
1 sanan ko 1000 saati
Za a iya samun 3 sanan don Perkins engines;
2 sanan don Stamford S-series alternators
Taimako na teknikal na mutumin gaskiya da shugaban kantin na kwayoyin da ke aiki
Genset mai tabbata: ba ta ci gaba, ba ta ci gaba a cikin gida, yadda na tabbata
Takon bayani na teknoliji na kowane ayyuka da takon ganin a cikin jihadi
Ƙarin tarin aiki: takaddun data, kofin kore, kofin kwayoyi, ƙayyade
hotline na Genset na 24/7: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Kuma amsa mai kyau da ƙarfi, yana da kuma tabbali.