Matsalar Aminci
1 sanan ko 1000 saati
CDP110KVA shine shi ne generator na Jiuan da 110KVA na Perkins domin yin gurasa ta telecom da ICT infrastructure. Ya dace da Perkins 1104C-44TAG2 — wani generator na diesel mai 4 cylinders, 4.4L mai turbocharger da air-to-air intercooled da compression ratio na 18.2:1 — wanda ya bayyana 88KW/110KVA ISO8528 ESP domin gurasa ta yanzu da 80KW/100KVA domin yin amfani a lokacin da aka so. DSE7320 ko ComAp AMF25 controller da RS-485/MODBUS; AMF auto-start da ATS transfer a cikin 15 seconds; THD <5% domin telecom rectifiers; tank na 260L (8-10h autonomy); 1700kg / 2600×1100mm; EU Stage II / EPA Tier 2; 18-month warranty.
CDP110KVA shi ne na Jiuan Generator matsayin diesel Perkins na 110KVA don kafin gaba na emergency na telecom da infrastruktur na ICT — ya bayyana 88KW/110KVA ISO8528 ESP don lokacin da makamantansu na cellular BTS, markazai na telecom switching, zonarun server na campus, da fasahoyin data na edge inda ake buƙata kafin gaba na grid sai dai kafin gaba na UPS battery autonomy ya kafa. Tanki na yaki na 260L da controller na DSE7320 ko ComAp AMF25 sun samun iya kafin gaba ta otomatik da ATS transfer a cikin 15 seconds daga lokacin da ake gano kafin gaba na mains.
A cikin Makina na kafin gaba na diesel na Perkins 1104C-44TAG2 injin din shine silinda hudu, 4.4L turbocharged da iska zuwa iska mai sanyaya iska tare da 105mm × 127mm bore da bugun jini da kuma 18.2:1 matsawa rabo. Bayan iska-zuwa-iska yana ƙaruwa yawan iska mai ƙonewa don daidaitaccen ƙimar fitarwa a ƙananan zafin jiki na fitarwa. Amfani da man fetur a cikin babban nauyin kaya: 26.9 L / h a cikakken lokaci, 20.2 L / h a 75% prime, 14.1 L / h a 50% prime goyan bayan 8-10 hours a kan 260L tank. EU Mataki na II / EPA Tier 2 da aka ba da izini don fitarwa na kayan aikin sadarwa na duniya.
A cikin wayar tarho, 88KW janareta na gaggawa na gaggawa CDP110KVA ya shiga ISO8528 ESP mode — ya faru domin kuma kuma a cikin kusani na mains grid da ba su samu kuma a lokacin da baya da battery autonomy na UPS. AMF controller ya gudumta kuma ya ci gaba da generator a cikin 15 seconds daga lokacin da mains ya faru. THD ta zama akwai kuma 5% a cikin duk loads suka tabbata SMPS rectifiers, DC bus converters, da BTS power modules daga harmonic distortion. Brushless synchronous alternator ya taimaka da ±1% voltage regulation a 400V/50Hz don tabbatar da sabon DC bus charging a lokacin da standby.
A cikin 110KVA telecom backup power CDP110KVA DSE7320 ko ComAp AMF25 controller yana taimaka da RS-485 / MODBUS RTU — ya taimaka da direct integration da telecom SCADA, network operations centre dashboards, da building management systems. An nemo 4G IoT module don bayani na real-time, run-hour logging, da bayani na fuel-level a wani BTS tower mai karfi ko wani remote data room site. ATS transfer switch cabinet ya taimaka da coordination na mains-to-generator changeover da full return-to-mains logic da engine cool-down cycle management.
A cikin Perkins 1104 na kwayoyin gaba'aya CDP110KVA 1104C-44TAG2 na injin ya bayyana tsarin tattalin arziki na 500 wata don sauya oil da filter — wanda ya dace da tsarin tattalin arziki na shekara ta yankin telecom tower operators su a cikin yankin da ke faru. Kamarin da ke ƙarami 2600×1100×1600mm da wuche 1700kg zasu fita a cikin plant room mai amfani da kuma ba za a bukatar sauya gurbi na fadakar. Bayanai na Perkins 1104C suna da jiri a cikin kantin tattalin arziki na al'ada a duniya. Jiuan Generator ya ba mu kariya na 18 wata ko 2,000 wata a cikin duk CDP110KVA.

| Paramita | Ƙima |
| Samfur | CDP110KVA |
| Ukuma na Gudun Mataimakon (ESP) | 88KW / 110KVA |
| Ukuma na Farko (PRP) | 80KW / 100KVA |
| Tsarin injin | Perkins 1104C-44TAG2 |
| Cylinders | 4 Inline |
| Rarraba | 4.4L |
| Bore × Stroke | 105mm × 127mm |
| Compression ratio | 18.2:1 |
| Kurkurewa | Turbocharged + Air-to-Air Intercooled |
| Matsayin gudan | Kwaya |
| Standard tsohonin | EU Stage II / EPA Tier 2 |
| Karamin Kudin Daki (na farko) | Tafiyar karami: 26.9 / 75%: 20.2 / 50%: 14.1 L/h |
| Frequwansi / Saya | 50Hz / 1500RPM; 60Hz / 1800RPM |
| Fasa / Kwayoyi | 3-Fasa, 4-Kwayoyi |
| Voltage Output | 415/240V, 400/230V, 380/220V |
| Fakar watsiya | 0.8 Lagging |
| Tsayar Voltage | ±1% |
| THD | <5% |
| Yi shigo | 12V DC Electric Start |
| Mai sarrafawa | DSE7320 / ComAp AMF25 (RS-485 MODBUS) |
| Madadin | Stamford / Leroy-Somer / Tooplinks |
| Ƙungiyar rufi | Class H |
| Takaddun Tattara | IP23 standard / IP55 zai iya amfani da shi |
| Matsayin Gargajiya | ≤75dB(A) @ 7m (kudin da ke kuma kuma) |
| Tsawon abu (L×W×H) | 2600 × 1100 × 1600mm |
| Nauyi | 1,700kg |
| Tankin mai | tanki na gaba ta hanyar tsofari (260L) (8–10 wata na amfani) |
| Kawai | Kabinetin ATS, IoT na 4G, Tanki Mai Tsawo |

1. AMF Na Tsohon Tafiyar – Tafiyar ATS A Cikin 15 Sekondi Daga Wani Kashe Na Gwamnati
A cikin 88KW janareta na gaggawa na gaggawa CDP110KVA AMF controller ya ganin kashe na grid sai ya shiga yadda da fayilin da karamin kudin da karamin dakin a cikin 15 sekondi – ya kammala tafiyar ATS a baya na kashe na UPS na bateri kuma ya jadi karamin DC na amfani ga racks na BTS da nodes na telecom switching ba tare in gudanen aiki.

2. THD <5% kuma ƙananan ƙarshen yadda ake gudanen shi ne ±1% don mabobin da suka daga telecom
A cikin matsayin diesel Perkins na 110KVA CDP110KVA mai tsayi aiki a cikin hawa zuwa hawa, 1104C-44TAG2 da mabobi na karama mai tsayi aiki ba tare da karama (brushless synchronous alternator) suna kawo THD ta hanyar ƙananan 5% kuma ƙarshen yadda ake gudanen shi ne a cikin ±1%, wanda ya kawo alaƙa ga mabobin da suka daga telecom (SMPS rectifiers) da mabobin da suka daga DC bus don kula da karamar harmonics wanda ke zama sabon sabon na yawa da kara yawan harajin kuma yana rage rukuni na karama a cikin sistemomin karama na BTS da switching centre.
3. RS-485 MODBUS Integration da SCADA da NOC
A cikin Makina na kafin gaba na diesel na Perkins 1104C-44TAG2 CDP110KVA DSE7320 ko AMF25 controller ya ba da damu ga RS-485 / MODBUS RTU don kawo karama ta hanyar direct SCADA da NOC. Damun 4G IoT wanda ke da kyau ya ba da bayanin alarma, bayanin lokacin aiki, da bayanin yawan karama a cikin BTS tower wanda ba a yi aiki ba da kuma a cikin lokaci na telecom da suka fara da kari.

4. Tanki na 260L — Kuma ƙarin 10 saati na karama a lokacin da karama ba ta tabbata ba a lokacin telecom
A cikin 110KVA telecom backup power CDP110KVA 260L ta yin kuma tanki ya taimaka wani aiki na 8-10 sa’at na stand-by a cikin gaba daya na load — wani bukata na rana ta aiki a BTS tower sites da edge data rooms. Iyali na tanki na kuma abu na kariya suna ciki don duniya na Africa, South Asia, da Southeast Asia da suka yi amfani da grid wanda aka samu kuzari.
5. 1700kg Tattaunawa ta Karami — Samun kuma a cikin tattaunawa ta karami ba ne da kuzari na tattaunawa
A cikin Perkins 1104 na kwayoyin gaba'aya CDP110KVA ta zama 1700kg da tattaunawa ta karami na 2600×1100mm — ta fitowa a cikin standard plant rooms a telecom buildings, campus ICT suites, da mid-rise commercial facilities ba ne da kuzari na tattaunawa. Anti-vibration mounts suna ciki a matsayin standard don kara yawa na structural transmission a lokacin standby engine run cycles.

The CDP110KVA 88KW janareta na gaggawa na gaggawa ta aiki a cikin wadannan telecom da ICT infrastructure standby applications:
Jiuan Generator yana ba da OEM configuration don CDP110KVA Makina na kafin gaba na diesel na Perkins 1104C-44TAG2 . Options sun haɗa super silent canopy a custom RAL color, DSE7320 ko AMF25 da RS-485 / MODBUS, 4G IoT monitoring module, ATS cabinet, da extended fuel tank don sites a high-outage-frequency grid regions. Duk wani abu yana amfani da genuine Perkins 1104C parts kuma yana tabbata da full-load factory burn-in test a baya da dispatch.

Ts: CDP110KVA yana kawo da telecom ATS system?
A:matsayin diesel Perkins na 110KVA CDP110KVA yana amfani da DSE7320 ko ComAp AMF25 tare da ATS transfer switch cabinet mai gaskiya. A lokacin da kuma yana ƙarfi, AMF ya fara mota kuma ya bayyana ATS don canza lokacin da genset ya samu frequency da voltage na yanzu — ta hanyar umumun 15 seconds, a cikin lokacin da UPS battery yana ƙara kuma a BTS da data room sites.
T: Yaya ne fuel autonomy na CDP110KVA a wani telecom BTS site mai yawa?
A:110KVA telecom backup power CDP110KVA yana tsinkan 26.9 L/h a full prime load kuma tank ya kasance 260L, wanda ke ba da autonomy na 9.5 hours. A wani typical BTS site load na 60-70% prime, autonomy ya raba zuwa 12-13 hours — wanda ke zama yawa don kammala duk lokacin da grid yana ƙara kuma a lokacin da shi ne daidai kuma a cikin rana kuma ba a sanya fuel.
T: Yaya ne remote monitoring capabilities na CDP110KVA don unmanned sites?
A:Perkins 1104 na kwayoyin gaba'aya CDP110KVA DSE7320 ko AMF25 yake taimaka RS-485 / MODBUS RTU don ƙarfi da SCADA. Alama na 4G IoT wanda ke zama a matsayin abu da za a iya amfani da shi yana ba da bayanin alama na lokacin yanzu, bayanin lokacin yana aiki, bayanin karamin gasolin, da amarar aiki na farin gushe ko kare a cikin app na mobile ko NOC API — wanda ke taimaka da ƙarfi da ƙananan ƙwarai na BTS wanda ba su da mutane a cikin ƙwarai.
CDP110KVA shine shi ne generator na Jiuan da 110KVA na Perkins domin yin gurasa ta telecom da ICT infrastructure. Ya dace da Perkins 1104C-44TAG2 — wani generator na diesel mai 4 cylinders, 4.4L mai turbocharger da air-to-air intercooled da compression ratio na 18.2:1 — wanda ya bayyana 88KW/110KVA ISO8528 ESP domin gurasa ta yanzu da 80KW/100KVA domin yin amfani a lokacin da aka so. DSE7320 ko ComAp AMF25 controller da RS-485/MODBUS; AMF auto-start da ATS transfer a cikin 15 seconds; THD <5% domin telecom rectifiers; tank na 260L (8-10h autonomy); 1700kg / 2600×1100mm; EU Stage II / EPA Tier 2; 18-month warranty.
1 sanan ko 1000 saati
Za a iya samun 3 sanan don Perkins engines;
2 sanan don Stamford S-series alternators
Taimako na teknikal na mutumin gaskiya da shugaban kantin na kwayoyin da ke aiki
Wani abu da ke cikin kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi — a wajen da ke cikin ƙarfi da a wajen da ke cikin ƙarfi.
Takardun da yawa ta 2 shekara ko 2,000 awa (wanda ya gabata), ta hanyar tashin PICC — wanda ya ba al'umma na gaba daya kai tsaye a dukkan abin da ke cikin.
Sauya mai kyau na gaba daya — abubuwan da suka yi takardun da yawa suka zo a dukkan al'umma a kowane 3 zuwa 5 rana, wanda ya ci gaba da kai tsaye a dukkan abin da ke cikin.
Abubuwan da suka yi kai tsaye suna amfani da steel ta cold-rolled, powder coating ta high-gloss da insulation ta flame-retardant don kariya mai kyau na rust, scratch da kariya mai kyau na karya.
Duk wani abu shine ta farko da ESN ta maimuna da kariya, kuma duk wani generator ya taka da kariya ta full-load da overload tests a baya da sauya.
Kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi, wajen da ke kusa da ƙarfi, da wajen da ke cikin ƙarfi na amfanin; suna haɗa da kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi, kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi, da kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi.
Taimaka da kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi da kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi ta hanyar da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi da wajen da ke cikin ƙarfi.
Genset mai tabbata: ba ta ci gaba, ba ta ci gaba a cikin gida, yadda na tabbata
Takon bayani na teknoliji na kowane ayyuka da takon ganin a cikin jihadi
Ƙarin tarin aiki: takaddun data, kofin kore, kofin kwayoyi, ƙayyade
hotline na Genset na 24/7: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Kuma amsa mai kyau da ƙarfi, yana da kuma tabbali.