Ọnọr Ọkachamara
otu afọ ma ọ bụ 1000 hours
CDP110KVA bụ ịdọba diesel Perkins nke Jiuan Generator nke 110KVA maka ngwaọrụ telecom na ICT iji gbanwee mgbe o nwere ihe dị ka ihe nchekwa. A na-egbochie ya site na Perkins 1104C-44TAG2 — nke na-eme ihe nke atọ, 4.4L nke na-egbochie ya na air-to-air intercooled diesel nke na-enye 18.2:1 compression ratio — ịdọba a na-enye 88KW/110KVA ISO8528 ESP nke na-eme ihe nchekwa na 80KW/100KVA nke na-eme ihe nchekwa nke na-eme ihe nchekwa. DSE7320 ma ọ bụ ComAp AMF25 controller na RS-485/MODBUS; AMF auto-start na ATS transfer n'ime sekọnd 15; THD <5% maka rectifiers nke telecom; tank nke 260L (8-10h autonomy); 1700kg / 2600×1100mm; EU Stage II / EPA Tier 2; warranty nke 18 months.
CDP110KVA bụ Jiuan Generator's 110KVA Perkins diesel generator nke ịdị ọcha na-eme ihe dị ka emergency standby maka telecom na ICT infrastructure — na-enye 88KW/110KVA ISO8528 ESP maka cellular BTS sites, telecom switching centres, campus server rooms, na edge data facilities ebe ọ dịghị ike ịdị n’ime grid ga-eme ihe n’oge ọ bụla mgbe UPS battery autonomy ghara ịguzogide. Tank fuel 260L nke e jupụtara na DSE7320 ma ọ bụ ComAp AMF25 controller na-enye ike ịmepụta otu n’otu na ATS transfer n’ime sekọnd 15 mgbe e hụrụ na mains failure.
Ihe Perkins 1104C-44TAG2 diesel genset engine bụ anọ cylinder, 4.4L turbocharged na ikuku-na-ikuku intercooled dizel na 105mm × 127mm oghere na ije na 18.2:1 mkpakọ ruru. Ikuku na ikuku na-eme ka ikuku ọkụ dịkwuo elu maka ike dị elu na okpomọkụ dị ala. Mmanụ ụgbọala oriri gafee isi ibu band: 26.9 L/h na zuru isi, 20.2 L/h na 75% isi, 14.1 L/h na 50% isi akwado 8-10 awa na 260L tank. EU Stage II / EPA Tier 2 gbaara mba ụwa na-ebupụ akụrụngwa telekomunikashions.
N'ihe banyere itinye n'ọrụ telivishọn, 88KW nchekwa nchekwa nchekwa CDP110KVA na-arụ ọrụ na ọnọdụ ISO8528 ESP na-arụ ọrụ naanị mgbe ọkọnọ nke netwọk netwọk na-ada karịa ikike nke batrị UPS. Onye na-achịkwa AMF na-agbagharị ma na-ebute generator n'ime sekọnd 15 nke ike ike. THD n'okpuru 5% gafee ibu niile na-echebe ndị na-emezi SMPS, ndị na-agbanwe bọs DC, na modulu ike BTS site na mgbagha harmonic. The brushless synchronous alternator esetịpụ ± 1% voltaji iwu na 400V/50Hz maka ike DC ụgbọ ala ụgwọ n'oge nile nke njikere omume.
Ihe 110KVA ike nkwado nke telecom CDP110KVA DSE7320 ma ọ bụ ComAp AMF25 njikwa na-akwado RS-485 / MODBUS RTU na-enye ohere itinye aka na SCADA telecom, dashboards nke ebe nrụọrụ weebụ na ụlọ ọrụ ụlọ. Modul 4G IoT nhọrọ na-enye ọkwa mkpu oge, ndekọ oge na-agba ọsọ, na ọkwa ọkwa mmanụ na ụlọ elu BTS na-enweghị mmadụ na ebe nchekwa data dịpụrụ adịpụ. A raara onwe ya nye ATS nyefe mgba ọkụ kabinet-achịkwa isi-to-generator mgbanwe na zuru nloghachi-to-isi-logic na engine jụrụ ala okirikiri management.
Ihe Perkins 1104 nke e nwere ihe isi anọ nke ịkpọta ụlọ ọrụ CDP110KVA 1104C-44TAG2 engine bụrụ nke na-aga n'ihu nke ịkpọta ụlọ ọrụ nke 500 oru nke ịkpọta ụlọ ọrụ nke oil na filter — na-akpali nke na-aga n'ihu nke ịkpọta ụlọ ọrụ nke otu afọ nke ndị ọrụ ụlọ ọrụ nke telecom na-akpali n'ime obodo dị ọhụrụ. Nke dị mfe nke 2600×1100×1600mm na ọbara 1700kg bụrụ nke na-aga n'ihu nke ụlọ ọrụ nke dị mfe nke ọ bụla, ọ dịghị ike ịkpọta ụlọ ọrụ nke ọ bụla. Ihe isi Perkins 1104C dị mfe n'ime ụlọ ọrụ nke dị mfe n'ime obodo niile. Jiuan Generator na-enye ọbara 18 afọ ma ọ bụ 2,000 oru nke ọbara nke CDP110KVA niile.

| Oke | Uru |
| Mọdelu | CDP110KVA |
| Ihe ọkụrụ nke Standby Power (ESP) | 88KW / 110KVA |
| Ihe ọkụrụ nke Prime Power (PRP) | 80KW / 100KVA |
| Mọdelụ ọgbụgbọ ejiri | Perkins 1104C-44TAG2 |
| Cylinders | 4 Inline |
| Ihe nke ịdị ọcha | 4.4L |
| Bore × Stroke | 105mm × 127mm |
| Ụlọ mmiri nchepu | 18.2:1 |
| Ihe Nkọwa | Turbocharged + Intercooler Nke Air-to-Air |
| Onye Nweta Uru | Mechanical |
| Uru Nke Nkọwa | EU Stage II / EPA Tier 2 |
| Ịkụrụ ihe ngosi (nke ọhụrụ) | Ọhụrụ: 26.9 / 75%: 20.2 / 50%: 14.1 L/h |
| Ihe ọmụma ahụ / Ihe ọmụma ahụ | 50Hz / 1500RPM; 60Hz / 1800RPM |
| Phase / Wires | 3-Phase, 4-Wire |
| Igwe Voltage | 415/240V, 400/230V, 380/220V |
| Ọdịnaya nkwere | 0.8 Lagging |
| Voltage regulation | ±1% |
| THD | <5% |
| Nweta | 12V DC Electric Start |
| Ọnụaha | DSE7320 / ComAp AMF25 (RS-485 MODBUS) |
| Alternator | Stamford / Leroy-Somer / Tooplinks |
| Isi Insulation | Isi H |
| Ịgụnọ Ịgụnọ | IP23 standard / IP55 nke dị mkpa |
| Nzuzo Dịka | ≤75dB(A) @ 7m (silent canopy) |
| Dimensions (L×W×H) | 2600 × 1100 × 1600mm |
| Ibu | 1,700kg |
| Ụlọ nke ọkụ | tank nke e jikọtara na ala 260L (8–10h nke ọrụ) |
| Ọ dị ka ha | Kabinet ATS, IoT 4G, Tank nke e kpebie |

1. AMF Auto-Start — Ihe nke ATS ga-ebu n'ime sekọnd 15 mgbe ihe nke mba ahụ agaghị arụ ọrụ
Ihe 88KW nchekwa nchekwa nchekwa Onye isi CDP110KVA AMF ga-ahụ na ihe nke mba ahụ agaghị arụ ọrụ ma ọ bụghị ya, wee gaa na frequency na voltage nke e nyere ya n'ime sekọnd 15 — wee mechie ihe nke ATS n'ime mgbe tank nke battery UPS ga-aga n'ihu, wee wezigharị ọrụ DC nke BTS equipment racks na telecom switching nodes n'akụkụ ọ bụla.

2. THD <5% na ±1% Nkọwa nke Voltage maka Telecom Rectifiers
Ihe 110KVA Perkins diesel generator nke ịdị ọcha CDP110KVA nke e jikọtara na ọsọ 1104C-44TAG2 na alternator nke e jikọtara na ọsọ, na-eme ka THD dị ala karịa 5% na nkọwa nke voltage dị na ±1%, na-eweta SMPS rectifiers na DC bus converters site nke harmonic distortion nke ga-akpata ịdị ọcha ma ọ bụghị ya na-akụzi efficiency nke BTS na power systems nke switching centre.
3. RS-485 MODBUS Integration na SCADA na NOC
Ihe Perkins 1104C-44TAG2 diesel genset CDP110KVA DSE7320 ma ọrụ AMF25 na-eme ka RS-485 / MODBUS RTU bụrụ ihe dịka ngwa ngwa SCADA na NOC. Ngwa ngwa 4G IoT nke e nwere ike ịhọrọ na-akpọ ụzọ ọrụ, ihe ndị a na-egosipụta mgbe ọrụ na-aga, na ihe ndị a na-egosipụta oke ọkụ na ntọala nke ọrụ na ntọala nke BTS na ntọala nke ọrụ nke telecom nke enweghị onye ọrụ.

4. Tank 260L — Ihe kpatara 10 Ọrụ Nke Ebe Nke Telecom
Ihe 110KVA ike nkwado nke telecom CDP110KVA 260L tank nke e jikọtara na-eme ka ọrụ na-aga n'otu ụbọchị nke 8-10 ọrụ nke ọrụ nke ọrụ nke BTS na ebe nke data nke edge — ihe kpatara otu ụbọchị nke ọrụ. Ihe ndị a na-enye ike maka ntọala nke ọkụ nke e nwere ike ịbụ nke Africa, South Asia, na Southeast Asia.
5. 1700kg Compact Footprint — Retrofit Without Floor Reinforcement
Ihe Perkins 1104 nke e nwere ihe isi anọ nke ịkpọta ụlọ ọrụ CDP110KVA weghachite 1700kg na 2600×1100mm base footprint — na-eme ka ọrụ na-aga n'otu ebe nke ọrụ nke telecom, campus ICT suites, na mid-rise commercial facilities without floor-loading upgrades. Anti-vibration mounts fitted as standard reduce structural transmission during standby engine run cycles.

CDP110KVA ahụ 88KW nchekwa nchekwa nchekwa nwere ike ịdị na ngalaba ndị a nke telecom na ICT:
Jiuan Generator bụrụ ihe nchịkọta nke CDP110KVA Perkins 1104C-44TAG2 diesel genset . Nhọrọ gụnyere super silent canopy na agba RAL ahaziri iche, DSE7320 ma ọ bụ AMF25 na RS-485 / MODBUS, modulu nlekota oru 4G IoT, ụlọ ọrụ ATS, na tank mmanụ agbịdị gbasaa maka saịtị na mpaghara grid dị elu. Ngwaọrụ niile na-eji ezigbo akụkụ Perkins 1104C ma gafee ule ọkụ ọkụ zuru ezu tupu mbupu.

Ajụjụ: Kedụ ka CDP110KVA si ejikọ na sistemụ ATS telecom?
A: 110KVA Perkins diesel generator nke ịdị ọcha CDP110KVA na-eji DSE7320 ma ọ bụ ComAp AMF25 na ụlọ ọrụ ntụgharị ntụgharị ATS raara onwe ya nye. Mgbe isi ike, AMF na-amalite engine ma na-enye iwu ka ịgbanwee ATS ozugbo genset ruru ugboro ole na voltaji n'ime sekọnd 15, tupu batrị UPS gwụ na BTS na ebe nchekwa data.
Ajụjụ: Gịnị bụ ikike mmanụ ụgbọala nke CDP110KVA na ebe BTS telecom nkịtị?
A: 110KVA ike nkwado nke telecom CDP110KVA na-eri 26.9 L / h na zuru ibu na a 260L tank, na-enye ihe dị ka 9.5 awa nnwere onwe. Na a typical BTS saịtị ibu nke 60-70% isi, nnwere onwe gbatịrị ka 12-13 awa ezu iji kpuchie ọtụtụ n'ime abalị grid outage ndapụta enweghị refueling.
Ajụjụ: Olee ikike nlekota anya nke CDP110KVA na-enye maka ebe ndị na-enweghị mmadụ?
A: Perkins 1104 nke e nwere ihe isi anọ nke ịkpọta ụlọ ọrụ CDP110KVA DSE7320 ma ọ bụ AMF25 na-akwado RS-485 / MODBUS RTU maka njikọta SCADA. Modul 4G IoT nhọrọ na-enye ọkwa ọkwa oge, ndekọ oge, ọkwa ọkwa mmanụ, na iwu mmalite / nkwụsị dịpụrụ adịpụ site na ngwa mkpanaka ma ọ bụ NOC API na-enyere njikwa njikwa nke ọtụtụ ụlọ elu BTS na-enweghị mmadụ.
CDP110KVA bụ ịdọba diesel Perkins nke Jiuan Generator nke 110KVA maka ngwaọrụ telecom na ICT iji gbanwee mgbe o nwere ihe dị ka ihe nchekwa. A na-egbochie ya site na Perkins 1104C-44TAG2 — nke na-eme ihe nke atọ, 4.4L nke na-egbochie ya na air-to-air intercooled diesel nke na-enye 18.2:1 compression ratio — ịdọba a na-enye 88KW/110KVA ISO8528 ESP nke na-eme ihe nchekwa na 80KW/100KVA nke na-eme ihe nchekwa nke na-eme ihe nchekwa. DSE7320 ma ọ bụ ComAp AMF25 controller na RS-485/MODBUS; AMF auto-start na ATS transfer n'ime sekọnd 15; THD <5% maka rectifiers nke telecom; tank nke 260L (8-10h autonomy); 1700kg / 2600×1100mm; EU Stage II / EPA Tier 2; warranty nke 18 months.
otu afọ ma ọ bụ 1000 hours
Nke ọzọ 3 afọ maka Perkins engines;
2 ọdụ maka Stamford S-series alternators
Nkọwa teknụkal nke ọrụ na ngwaọrụ ndị ọzọ nke ọrụ
Gensets nke ị chọrọ: nwere ike ịkpọ, enweghị ihe ịdị iche, nke ị chọrọ ihe ọ bụla
Nke ịrụ ya nke ihe kachasị mkpa na ịkpọ ọnụ ahịa nke ọzọ
Ihe ọ bụla nke e mechara: data centers, mines, ports, infrastructure
24/7 Genset Service Hotline: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Nkọwa ọhụrụ na ọ dị ịrịba ama bụ ihe ọ bụla e nwere ike ịgbanwe.