110kva-perkins-diesel-generator-, 110kva-perkins-diesel-generator-, /perkins
Ajuju
110kva-perkins-diesel-generator-, 110kva-perkins-diesel-generator-, /perkins
Ajuju

110KVA Perkins diesel generator nke ịdị ọcha

CDP110KVA bụ ịdọba diesel Perkins nke Jiuan Generator nke 110KVA maka ngwaọrụ telecom na ICT iji gbanwee mgbe o nwere ihe dị ka ihe nchekwa. A na-egbochie ya site na Perkins 1104C-44TAG2 — nke na-eme ihe nke atọ, 4.4L nke na-egbochie ya na air-to-air intercooled diesel nke na-enye 18.2:1 compression ratio — ịdọba a na-enye 88KW/110KVA ISO8528 ESP nke na-eme ihe nchekwa na 80KW/100KVA nke na-eme ihe nchekwa nke na-eme ihe nchekwa. DSE7320 ma ọ bụ ComAp AMF25 controller na RS-485/MODBUS; AMF auto-start na ATS transfer n'ime sekọnd 15; THD <5% maka rectifiers nke telecom; tank nke 260L (8-10h autonomy); 1700kg / 2600×1100mm; EU Stage II / EPA Tier 2; warranty nke 18 months.

Gbasara Akwụkwọ
  • Nchịkọta

Nchịkọta

88KW Telecom Standby — Perkins 1104C-44TAG2 for BTS and ICT Infrastructure Emergency Power

CDP110KVA bụ Jiuan Generator's 110KVA Perkins diesel generator nke ịdị ọcha na-eme ihe dị ka emergency standby maka telecom na ICT infrastructure — na-enye 88KW/110KVA ISO8528 ESP maka cellular BTS sites, telecom switching centres, campus server rooms, na edge data facilities ebe ọ dịghị ike ịdị n’ime grid ga-eme ihe n’oge ọ bụla mgbe UPS battery autonomy ghara ịguzogide. Tank fuel 260L nke e jupụtara na DSE7320 ma ọ bụ ComAp AMF25 controller na-enye ike ịmepụta otu n’otu na ATS transfer n’ime sekọnd 15 mgbe e hụrụ na mains failure.

Ihe Perkins 1104C-44TAG2 diesel genset engine bụ anọ cylinder, 4.4L turbocharged na ikuku-na-ikuku intercooled dizel na 105mm × 127mm oghere na ije na 18.2:1 mkpakọ ruru. Ikuku na ikuku na-eme ka ikuku ọkụ dịkwuo elu maka ike dị elu na okpomọkụ dị ala. Mmanụ ụgbọala oriri gafee isi ibu band: 26.9 L/h na zuru isi, 20.2 L/h na 75% isi, 14.1 L/h na 50% isi akwado 8-10 awa na 260L tank. EU Stage II / EPA Tier 2 gbaara mba ụwa na-ebupụ akụrụngwa telekomunikashions.

N'ihe banyere itinye n'ọrụ telivishọn, 88KW nchekwa nchekwa nchekwa CDP110KVA na-arụ ọrụ na ọnọdụ ISO8528 ESP na-arụ ọrụ naanị mgbe ọkọnọ nke netwọk netwọk na-ada karịa ikike nke batrị UPS. Onye na-achịkwa AMF na-agbagharị ma na-ebute generator n'ime sekọnd 15 nke ike ike. THD n'okpuru 5% gafee ibu niile na-echebe ndị na-emezi SMPS, ndị na-agbanwe bọs DC, na modulu ike BTS site na mgbagha harmonic. The brushless synchronous alternator esetịpụ ± 1% voltaji iwu na 400V/50Hz maka ike DC ụgbọ ala ụgwọ n'oge nile nke njikere omume.

Ihe 110KVA ike nkwado nke telecom CDP110KVA DSE7320 ma ọ bụ ComAp AMF25 njikwa na-akwado RS-485 / MODBUS RTU na-enye ohere itinye aka na SCADA telecom, dashboards nke ebe nrụọrụ weebụ na ụlọ ọrụ ụlọ. Modul 4G IoT nhọrọ na-enye ọkwa mkpu oge, ndekọ oge na-agba ọsọ, na ọkwa ọkwa mmanụ na ụlọ elu BTS na-enweghị mmadụ na ebe nchekwa data dịpụrụ adịpụ. A raara onwe ya nye ATS nyefe mgba ọkụ kabinet-achịkwa isi-to-generator mgbanwe na zuru nloghachi-to-isi-logic na engine jụrụ ala okirikiri management.

Ihe Perkins 1104 nke e nwere ihe isi anọ nke ịkpọta ụlọ ọrụ CDP110KVA 1104C-44TAG2 engine bụrụ nke na-aga n'ihu nke ịkpọta ụlọ ọrụ nke 500 oru nke ịkpọta ụlọ ọrụ nke oil na filter — na-akpali nke na-aga n'ihu nke ịkpọta ụlọ ọrụ nke otu afọ nke ndị ọrụ ụlọ ọrụ nke telecom na-akpali n'ime obodo dị ọhụrụ. Nke dị mfe nke 2600×1100×1600mm na ọbara 1700kg bụrụ nke na-aga n'ihu nke ụlọ ọrụ nke dị mfe nke ọ bụla, ọ dịghị ike ịkpọta ụlọ ọrụ nke ọ bụla. Ihe isi Perkins 1104C dị mfe n'ime ụlọ ọrụ nke dị mfe n'ime obodo niile. Jiuan Generator na-enye ọbara 18 afọ ma ọ bụ 2,000 oru nke ọbara nke CDP110KVA niile.

110KVA Perkins diesel generator CDP110KVA telecom standby

Ntuziaka Teknisian

Oke Uru
Mọdelu CDP110KVA
Ihe ọkụrụ nke Standby Power (ESP) 88KW / 110KVA
Ihe ọkụrụ nke Prime Power (PRP) 80KW / 100KVA
Mọdelụ ọgbụgbọ ejiri Perkins 1104C-44TAG2
Cylinders 4 Inline
Ihe nke ịdị ọcha 4.4L
Bore × Stroke 105mm × 127mm
Ụlọ mmiri nchepu 18.2:1
Ihe Nkọwa Turbocharged + Intercooler Nke Air-to-Air
Onye Nweta Uru Mechanical
Uru Nke Nkọwa EU Stage II / EPA Tier 2
Ịkụrụ ihe ngosi (nke ọhụrụ) Ọhụrụ: 26.9 / 75%: 20.2 / 50%: 14.1 L/h
Ihe ọmụma ahụ / Ihe ọmụma ahụ 50Hz / 1500RPM; 60Hz / 1800RPM
Phase / Wires 3-Phase, 4-Wire
Igwe Voltage 415/240V, 400/230V, 380/220V
Ọdịnaya nkwere 0.8 Lagging
Voltage regulation ±1%
THD <5%
Nweta 12V DC Electric Start
Ọnụaha DSE7320 / ComAp AMF25 (RS-485 MODBUS)
Alternator Stamford / Leroy-Somer / Tooplinks
Isi Insulation Isi H
Ịgụnọ Ịgụnọ IP23 standard / IP55 nke dị mkpa
Nzuzo Dịka ≤75dB(A) @ 7m (silent canopy)
Dimensions (L×W×H) 2600 × 1100 × 1600mm
Ibu 1,700kg
Ụlọ nke ọkụ tank nke e jikọtara na ala 260L (8–10h nke ọrụ)
Ọ dị ka ha Kabinet ATS, IoT 4G, Tank nke e kpebie

Perkins 1104C-44TAG2 diesel genset specification

5 Ihe Ndị Ọzọ Na-eme ka Ọ dị mfe

1. AMF Auto-Start — Ihe nke ATS ga-ebu n'ime sekọnd 15 mgbe ihe nke mba ahụ agaghị arụ ọrụ
Ihe 88KW nchekwa nchekwa nchekwa Onye isi CDP110KVA AMF ga-ahụ na ihe nke mba ahụ agaghị arụ ọrụ ma ọ bụghị ya, wee gaa na frequency na voltage nke e nyere ya n'ime sekọnd 15 — wee mechie ihe nke ATS n'ime mgbe tank nke battery UPS ga-aga n'ihu, wee wezigharị ọrụ DC nke BTS equipment racks na telecom switching nodes n'akụkụ ọ bụla.

88KW emergency standby generator AMF transfer

2. THD <5% na ±1% Nkọwa nke Voltage maka Telecom Rectifiers
Ihe 110KVA Perkins diesel generator nke ịdị ọcha CDP110KVA nke e jikọtara na ọsọ 1104C-44TAG2 na alternator nke e jikọtara na ọsọ, na-eme ka THD dị ala karịa 5% na nkọwa nke voltage dị na ±1%, na-eweta SMPS rectifiers na DC bus converters site nke harmonic distortion nke ga-akpata ịdị ọcha ma ọ bụghị ya na-akụzi efficiency nke BTS na power systems nke switching centre.

3. RS-485 MODBUS Integration na SCADA na NOC
Ihe Perkins 1104C-44TAG2 diesel genset CDP110KVA DSE7320 ma ọrụ AMF25 na-eme ka RS-485 / MODBUS RTU bụrụ ihe dịka ngwa ngwa SCADA na NOC. Ngwa ngwa 4G IoT nke e nwere ike ịhọrọ na-akpọ ụzọ ọrụ, ihe ndị a na-egosipụta mgbe ọrụ na-aga, na ihe ndị a na-egosipụta oke ọkụ na ntọala nke ọrụ na ntọala nke BTS na ntọala nke ọrụ nke telecom nke enweghị onye ọrụ.

110KVA telecom backup power DSE7320 MODBUS

4. Tank 260L — Ihe kpatara 10 Ọrụ Nke Ebe Nke Telecom
Ihe 110KVA ike nkwado nke telecom CDP110KVA 260L tank nke e jikọtara na-eme ka ọrụ na-aga n'otu ụbọchị nke 8-10 ọrụ nke ọrụ nke ọrụ nke BTS na ebe nke data nke edge — ihe kpatara otu ụbọchị nke ọrụ. Ihe ndị a na-enye ike maka ntọala nke ọkụ nke e nwere ike ịbụ nke Africa, South Asia, na Southeast Asia.

5. 1700kg Compact Footprint — Retrofit Without Floor Reinforcement
Ihe Perkins 1104 nke e nwere ihe isi anọ nke ịkpọta ụlọ ọrụ CDP110KVA weghachite 1700kg na 2600×1100mm base footprint — na-eme ka ọrụ na-aga n'otu ebe nke ọrụ nke telecom, campus ICT suites, na mid-rise commercial facilities without floor-loading upgrades. Anti-vibration mounts fitted as standard reduce structural transmission during standby engine run cycles.

Perkins 1104 four-cylinder genset plant room installation

Ihe ndị a ga-eji mee ihe

CDP110KVA ahụ 88KW nchekwa nchekwa nchekwa nwere ike ịdị na ngalaba ndị a nke telecom na ICT:

  • BTS nke cellular / steshin nke 4G / 5G — ịdị na mpaghara ọrụ nke radio, uniti nke baseband, na ngwaọrụ nke ikuku nke steshin
  • Ihe nke ịkpata ụlọ ọrụ nke telecom — ịdị na mpaghara ọrụ nke PSTN/IP switching na nodes nke ịkpata ụlọ ọrụ
  • Ụlọ ọrụ IT na ngwaọrụ nke campus — ịdị na mpaghara ọrụ nke servers, storage, na core switches
  • Ihe nke computing nke edge na micro-racks nke co-location — ịdị na mpaghara ọrụ nke grid karịa autonomy nke battery nke UPS
  • Nnyocha ihe oyiyi nke nlekọta ahụ ike na-eche nche maka MRI, CT, na ngwá ọrụ X-ray dijitalụ
  • Mkpịsị aka na-ekpo ọkụ ike mberede maka ebe nchekwa na ebe nhazi oyi

Ọrụ OEM ahaziri iche

Jiuan Generator bụrụ ihe nchịkọta nke CDP110KVA Perkins 1104C-44TAG2 diesel genset . Nhọrọ gụnyere super silent canopy na agba RAL ahaziri iche, DSE7320 ma ọ bụ AMF25 na RS-485 / MODBUS, modulu nlekota oru 4G IoT, ụlọ ọrụ ATS, na tank mmanụ agbịdị gbasaa maka saịtị na mpaghara grid dị elu. Ngwaọrụ niile na-eji ezigbo akụkụ Perkins 1104C ma gafee ule ọkụ ọkụ zuru ezu tupu mbupu.

110KVA Perkins diesel generator OEM configuration

FAQ

Ajụjụ: Kedụ ka CDP110KVA si ejikọ na sistemụ ATS telecom?
A: 110KVA Perkins diesel generator nke ịdị ọcha CDP110KVA na-eji DSE7320 ma ọ bụ ComAp AMF25 na ụlọ ọrụ ntụgharị ntụgharị ATS raara onwe ya nye. Mgbe isi ike, AMF na-amalite engine ma na-enye iwu ka ịgbanwee ATS ozugbo genset ruru ugboro ole na voltaji n'ime sekọnd 15, tupu batrị UPS gwụ na BTS na ebe nchekwa data.

Ajụjụ: Gịnị bụ ikike mmanụ ụgbọala nke CDP110KVA na ebe BTS telecom nkịtị?
A: 110KVA ike nkwado nke telecom CDP110KVA na-eri 26.9 L / h na zuru ibu na a 260L tank, na-enye ihe dị ka 9.5 awa nnwere onwe. Na a typical BTS saịtị ibu nke 60-70% isi, nnwere onwe gbatịrị ka 12-13 awa ezu iji kpuchie ọtụtụ n'ime abalị grid outage ndapụta enweghị refueling.

Ajụjụ: Olee ikike nlekota anya nke CDP110KVA na-enye maka ebe ndị na-enweghị mmadụ?
A: Perkins 1104 nke e nwere ihe isi anọ nke ịkpọta ụlọ ọrụ CDP110KVA DSE7320 ma ọ bụ AMF25 na-akwado RS-485 / MODBUS RTU maka njikọta SCADA. Modul 4G IoT nhọrọ na-enye ọkwa ọkwa oge, ndekọ oge, ọkwa ọkwa mmanụ, na iwu mmalite / nkwụsị dịpụrụ adịpụ site na ngwa mkpanaka ma ọ bụ NOC API na-enyere njikwa njikwa nke ọtụtụ ụlọ elu BTS na-enweghị mmadụ.

110KVA Perkins diesel generator nke ịdị ọcha

CDP110KVA bụ ịdọba diesel Perkins nke Jiuan Generator nke 110KVA maka ngwaọrụ telecom na ICT iji gbanwee mgbe o nwere ihe dị ka ihe nchekwa. A na-egbochie ya site na Perkins 1104C-44TAG2 — nke na-eme ihe nke atọ, 4.4L nke na-egbochie ya na air-to-air intercooled diesel nke na-enye 18.2:1 compression ratio — ịdọba a na-enye 88KW/110KVA ISO8528 ESP nke na-eme ihe nchekwa na 80KW/100KVA nke na-eme ihe nchekwa nke na-eme ihe nchekwa. DSE7320 ma ọ bụ ComAp AMF25 controller na RS-485/MODBUS; AMF auto-start na ATS transfer n'ime sekọnd 15; THD <5% maka rectifiers nke telecom; tank nke 260L (8-10h autonomy); 1700kg / 2600×1100mm; EU Stage II / EPA Tier 2; warranty nke 18 months.

Gbasara Akwụkwọ

Nchịkọta & Serbis

Ọnọr Ọkachamara

Ọnọr Ọkachamara

otu afọ ma ọ bụ 1000 hours

Nchịkọta nke nchịkọta

Nchịkọta nke nchịkọta

Nke ọzọ 3 afọ maka Perkins engines;
2 ọdụ maka Stamford S-series alternators

Nchịkọta nke na-adị na mbụrụ obodo

Nchịkọta nke na-adị na mbụrụ obodo

Nkọwa teknụkal nke ọrụ na ngwaọrụ ndị ọzọ nke ọrụ

Ihe ngwọta nke dị mma nke anyị

Ihe ngosi nke ọrụ nke ọdịda na ọrụ nke ọdịda

Ihe ngosi nke ọrụ nke ọdịda na ọrụ nke ọdịda

A na-emepụta ndị na-emepụta ihe anyị niile n'okpuru njikwa njikwa dị oke mkpa ma nwee asambodo mba ụwa: CE, ISO 9001, ISO 8528, BV, SASO, wdg, na-eme ka usoro mkpuchi ngwa ngwa na ọrụ a pụrụ ịdabere na ya n'ụwa niile.

Ihe ngosi nke ọrụ nke ọdịda na ọrụ nke ọdịda

Ihe ngosi nke ọrụ nke ọdịda na ọrụ nke ọdịda

Ikpeazu: Site na 20kVA ruo 5000kVA (5MW).
Ụdị: Anyị na-enye Open, Silent, Super-Silent, Mobile (Trailer), Containerized, na High-Voltage generator sets. Ihe niile nwere ike ịkọwa ha na ọrụ gị n’akụkụ (voltage, frequency, na ndị ọzọ).
Ihe ngosi nke ọrụ nke ọdịda nke ọrụ nke ọdịda

Ihe ngosi nke ọrụ nke ọdịda nke ọrụ nke ọdịda

Anyị bụrụ ụmụnna n’ihe dị ka ụlọ ọrụ nke ọtụtụ oge na ala ụwa maka ihe niile nke akụkụ nke ọrụ:
Ihe nke ịkpọ ọrụ: Cummins, Perkins, Volvo, Mitsubishi, Weichai, Baudouin
Ihe nke ịkpọ ọrụ nke ịkpọ ọrụ: Stamford, Leroy Somer
Nke ịrụ ya: Deepsea, ComAp, Smartgen
Ihe ngosi nke Customization & Project Support

Ihe ngosi nke Customization & Project Support

Onye nke ị si ike na-eme ka ị dị mma:

Gensets nke ị chọrọ: nwere ike ịkpọ, enweghị ihe ịdị iche, nke ị chọrọ ihe ọ bụla

Nke ịrụ ya nke ihe kachasị mkpa na ịkpọ ọnụ ahịa nke ọzọ

Ihe ọ bụla nke e mechara: data centers, mines, ports, infrastructure

24/7 Genset Service Hotline: +86 18818906850

Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China

Nkọwa ọhụrụ na ọ dị ịrịba ama bụ ihe ọ bụla e nwere ike ịgbanwe.

Kpọ Mmiri Anyị

Nweta nkwupụta efu

Onye nnọchi anya anyị ga-akpọtụrụ gị n'oge adịghị anya.
Email
Mobile/WhatsApp
Aha
Aha Ụlọ Ọrụ
Ozi
0/1000