200KVA Perkins diesel generator

CDP200KVA shi ne maki na jiuan wanda ake amfani da shi don samun kari na 200KVA ta Perkins wanda aka tsara don amfani na al'ada na gida, kuma don amfani na yadda ake nufin kari — hoteru, gida na ofis, gida na bayani, da gida na sana’a na wasu daga cikin gida na sana’a. Ya ke da kari na Perkins 1106A-70TAG3 wanda ya ke da tashin kari na air-to-air aftercooled turbocharged induction, kuma ya ba da 144KW ISO8528 PRP don amfani na al'ada ta hanyar kari mai zama daidai kuma 160KW ESP don amfani na yadda ake nufin kari don tabbatarwa. Ya kammala EU Stage II don fuskantar kari. Ilimi na silent canopy ya kammala ≤75dB(A) a 7m; DSE6120 AMF auto-start wanda ya ke da ATS transfer a cikin ƙarshe na 10 seconds. Tanki na kari na 400L ya taimaka don 8–9 hours na amfani mai sauƙi.

Nemi Farashi
  • Bayani

Bayani

Air-to-Air Aftercooling: Thermal Margin for 24/7 Commercial Prime Power

The CDP200KVA is Jiuan Generator's 200KVA Perkins diesel generator ta hanyar gida na aminci — hotelya, resort, markatun kwayoyi, faburikar da yawa na wasu, da kuma gida na buro — wanda ke bukata amfani da kariya ta musamman a lokacin yadda suka yi aiki da 144KW kuma kariya ta tsayi a lokacin da shugaban kariya ya kusanta. Air-to-air aftercooler na engine na Perkins 1106A-70TAG3 ya kula tsaunin charge air na turbocharged kafin ya shiga chamber na combustion, ya rage tsaunin charge air daga 150°C zuwa 50°C — ya sa charge density ya karu, ya sa efficiency na combustion ya karu, kuma ya rage thermal loading a cikin pistons, cylinder head, da exhaust valves don hakan da non-aftercooled turbocharged configurations. Bayanin wannan shi ne 180KVA prime power generator tashin kuma a 144KW wanda TAG3 engine ya zama da kansa ba tare da kuskuren yadda aka shigar da su, a 500-hour wani tsari na al'ada na ayyana.

A cikin Perkins 1106A-70TAG3 genset engine yake shi ne da shida kusurin, tsakiya, hudu-kafo, da kuma mai saukar da 7.01L displacement, 105mm × 135mm bore da stroke, da compression ratio na 16:1. Ya zama a 1500 RPM (50Hz), ya samu 144KW/180KVA prime power don amfani da kafin kafin a al'ada na tattalin arzi, da 160KW/200KVA standby power don amfani na gudunmawa a lokacin da aka bukata. Tashin TAG3 yana yada abin da ke cikin turbocharger wanda ya saukara air na intake don karuwa densitas na charge, da kuma air-to-air aftercooler na gaba don fuskanta hanyar da ke cikin heat na compression yayi ba da charge a kan intake manifold — wanda ke bawa thermal margin wanda ya bada damu don amfani da kafin kafin a full-load prime a lokacin da suyan yaki ta yin 40°C. Yadda ya iya shiga a lokacin da yaki yana da ƙananan -10°C ba ta neman taimako. Engine yana musu EU Stage II emission standards, wanda ke taimakawa a import na project na tattalin arzi, submission na planning authority, da documentation na environmental compliance a market na export. Consumption na fuel: 41.6 L/h a 100% prime load, 31.8 L/h a 75% prime load, 20.1 L/h a 50% prime load.

Sertipikat ISO8528 yana koveriwa biyu na klasifikashin aiki don CDP200KVA. Klasifikashin PRP (144KW/180KVA) yana sertipika unit din da 180KVA prime power generator don aiki mai ƙarfi a matsayin babban kayan aiki na fasiliti, idan jaduwarin load ya kasance ta hanyar 70% ko ƙasa daga ƙullum 24 gaba daya — wanda shine klasifikashin da ke amfani da shi a hoteru da abindun gida na sauri don amfani da CDP200KVA a matsayin babban kayan aiki bayan an fuskanta grid ko a lokacin da aka cire grid. Klasifikashin ESP (160KW/200KVA) yana sertipika unit din da setin generator na 200KVA don aiki a tsaki don tsakar da grid a lokacin tsohon kai, da madaidaici na karamin aiki a lokacin da aka ba shi 12 gaba don inrush current a lokacin fitowa. Dokumentin sertipikat CE wanda suka koveriwa ISO8528, klasen insulation na alternator, da karamin engine na EU Stage II ana baiwa su a kowane unit don amfani a kudin kasa na sauri.

Kullumun ɗauka biyu na kofin gida suka yi amfani da dukkan abubuwan da suka buƙata a cikin kantin. Alama na kofin gida ta fuskantar yana da kyau don kantin na sarrafa da kantin na kasa wanda ya nuna kamar yadda za a iya sauya da kuma kamar yadda za a iya kawo hankali. Kofin gida mai tsoro wanda ya zama babba (super silent canopy) ya kawo tsoron kofin gida zuwa ≤75dB(A) a matsayin 7 mita ta hanyar tsarin tsoron kofin gida na biyu da kofin gida mai tsoro wanda ya zama babba, wanda ya haɗa da alamar kantin na birni da kofin gida na hotell. Kofin gida na 20ft wanda ya zama babba da kofin gida mai tsoro wanda ya zama babba (weatherproof containerized version) da alamar IP54 ya haɗa da kantin na kasa, kantin na yanzu, da kantin na kasa wanda ba suka kammala ba. Kofin gida na 400L wanda ya zama babba ya haɗa da kofin gida na 8–9 sa’at wanda ya zama babba da kofin gida na kasa wanda ya zama babba, wanda ya haɗa da kofin gida na kasa wanda ya zama babba da kofin gida na kasa wanda ya zama babba.

Alternator na synchronous mai kwalla ba ta amfani da insulation na H-class da base protection na IP23 (IP55 zai iya zaune a matsayin optional), windings na copper ta daga gaba daya ta amfani da vacuum-impregnated, da digital AVR wanda ya nuna voltage na steady-state a cikin ±1% kuma THD a cikin 5% — wanda ke nufin specification na quality na power wanda ke bukatar su a system na HVAC na medical-grade, commercial electronic POS terminals, server infrastructure, da wasu abubuwan da ake amfani da su a kitchen. Don Perkins 1100 TAG3 generator , Jiuan Generator yake sanya controller na Deep Sea DSE6120 ko SmartGen HGM6120, wanda ke ba da AMF (automatic mains failure) detection, auto start-stop, ATS transfer a cikin ɗaya da goma seconds, da real-time monitoring na phase voltages, currents, frequency, power factor, oil pressure, coolant temperature, da accumulated run hours. RS485 communication yana a matsayin standard; 4G remote monitoring na optional zai iya ba da access don status daga kowa da kowane lokaci da ke cikin network. Fault protections sun haɗa ne: high coolant temperature, low oil pressure, overspeed, undervoltage, short-circuit, da overload shutdowns.

200KVA Perkins diesel generator CDP200KVA commercial

Tsayar Goma

Paramita Ƙima
Samfur CDP200KVA
Kawai na wakilu 144KW / 180KVA
Kawai na kasa 160KW / 200KVA
Tsarin injin Perkins 1106A-70TAG3
Rarraba 7.01L
Cylinders 6 Na Tsaki
Bore × Stroke 105mm × 135mm
Compression ratio 16:1
Kurkurewa Mai tsayi a kudin yaki + Mai tsayi a kudin yaki ta hanyar tafiyar yaki
Standard tsohonin EU Stage II
Cold Start -10°C ba shi da taimaka
Fuel Consumption @ 100% 41.6 L/h
Fuel Consumption @ 75% 31.8 L/h
Karamin Kudin Zaki a 50% 20.1 L/h
Frequwansi / Saya 50Hz / 1500RPM; 60Hz / 1800RPM
Fasa / Kwayoyi 3-Fasa, 4-Kwayoyi
Voltage Output 400/230V, 415/240V, 380/220V
Fakar watsiya 0.8 Lagging
Yi shigo 12V DC Electric Start
Mai sarrafawa Deep Sea DSE6120 / SmartGen HGM6120
Madadin Stamford / Leroy-Somer / Tooplinks
Ƙungiyar rufi Class H
Takaddun Tattara IP23 standard / IP55 zai iya amfani da shi
Matsayin Gargajiya ≤75dB(A) a 7m
Tankin mai 400L (8–9 awa a tsakanin yanzu na gaba)
Tsawon abu (L×W×H) 3600 × 1350 × 2000mm
Nauyi 2,200kg
Kawai ATS Transfer Switch, 4G IoT Module, Containerized Format

1106A-70TAG3 diesel genset specifications

5 Tsarin Karamin Gaskiya

1. Tsakarwa na hawaye zuwa hawaye — Farko na Ƙarfi na Tashin Gaba a Yanzu da Kullun Ayyukan Al'ada na Tashin Gaba
Alamar "TAG3" ta nuna tsakarwa na hawaye zuwa hawaye a cikin tsarin kuma Perkins 1106A-70TAG3 genset : tsakarwar hawaye ta fuskata haruffin tashin gaba na turbocharger kafin suka shiga cikin cylinders, ta zama yawa da 100°C kafin suka shiga cylinders daga tsarin turbocharged ba su tsakarwar hawaye. Haruffin tashin gaba mai sanyi suna baya farko na ƙarfi na cylinder head, piston crown, da exhaust valves — ta tabbata TBO (time between overhaul) na generators suka shiga ayyukan al'ada na tashin gaba a wajen al'ada na tashin gaba da suka shiga 8–16 sa'a a rana. Wannan farko na ƙarfi na tashin gaba ne wanda ya sa TAG3 ya samu 144KW daga 7.01L kuma 108KW ne farko na non-aftercooled 1106A-70TG1 daga wasu displacement.

200KVA Perkins diesel generator aftercooled engine

2. EU Stage II Emission Certification — Kafa da Al'ada na Ayyukan Al'ada na Duniya
Injin Perkins 1106A-70TAG3 ya cika matakan EU na II na matakan fitarwa na kayan aiki na hanyar ba tare da ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙarancin ƙ 200KVA Perkins diesel generator a cikin ci gaban dukiya na kasuwanci a duk faɗin EU, Afirka, kudu maso gabashin Asiya, da Gabas ta Tsakiya. Jiuan Generator yana samar da takaddun shaida na injin da ya dace tare da kowane naúrar don haɗawa cikin kunshin aikin.

3. Ka yi tunani a kan wannan. 144KW ISO8528 PRP Cikakken aikin farko ba tare da iyakance sa'a ba
ISO8528 PRP (144KW/180KVA) ya tabbatar da 180KVA prime power generator don aiki mara iyaka a cikin cikakken darajar darajar ba kamar ƙididdigar ESP ba, wanda ke da iyakar aiki na sa'o'i 12. Ga otal-otal, cibiyoyin kasuwanci, da masana'antun masana'antu da ke amfani da CDP200KVA a matsayin babban kayan samar da su yayin doguwar katsewa ko a wuraren da ba a cikin cibiyar sadarwa ba, takaddun shaida na PRP ya tabbatar da cewa fitowar 144KW tana ci gaba da ci gaba ba tare da jada

180KVA prime power generator silent canopy

5. Ka yi tunani. DSE6120 AMF Auto-Start Canjin Canji don Matsayi na Kasuwanci
A Deep Sea DSE6120 kula ta atomatik cibiyar sadarwa gazawar (AMF) aiki detects grid low voltage ko gazawar da kuma ta atomatik yana farawa da setin generator na 200KVA don aiki a tsaki , kammala canja wurin wutar lantarki a cikin ƙasa da sakan 10 lokacin canja wurin da ake buƙata ta yawancin hanyoyin UPS na kasuwanci da jerin abubuwan kare kaya masu mahimmanci don hoton CCTV, kula da damar lantarki, tsarin POS, firiji, da ɗakunan IT. DSE6120 kuma yana lura da ƙarfin lantarki da kuma halin yanzu na lokaci, yana ba da damar gano rashin daidaituwa a cikin nauyin da ke cikin katunan rarraba abubuwa uku a cikin gine-ginen kasuwanci da yawa.

200KVA standby generator set DSE6120 controller

Mai amfani daidai

CDP200KVA 200KVA Perkins diesel generator ana amfani da shi a cikin waɗannan aikace-aikacen kasuwanci da masana'antu na farko da kuma jiran aiki:

  • Hoteru da Resortu babban wutar lantarki don HVAC, kayan kicin, wanki, lifts, da haske a lokacin grid katsewa; standby madadin bayan da m cibiyar sadarwa dangane da aka commissioned
  • Gidajen ofis da cibiyoyin kasuwanci — tsari na kariya don ƙarshen bayanin gida, lift, sistemomin amfani da gida, da ruwan IT
  • Tsarin samun abu na wasu kwayoyi da kwayoyin gida na yawa — tsari na kariya ko tsari na kariya don rukunin samun abu, kofin hawaye, da abubuwan samun abu
  • Al'adu na Kankara da Al'adu na Gwamnati — tsari na kariya ta hanyar AMF don kariya mai sauƙi, kariya mai mahimmanci, da kariya na laboratari
  • Kullumai na sanyi da kulla na abinci — tsari na kariya ko tsari na kariya don kulla na sanyi da kulla na kariya mai sauƙi
  • Tawarun telecom da tawarun bayanin data na daga waje — tsari na kariya a wajen da ba shi da kariya ko tsari na kariya a wajen da shi da kariya da yawa

200KVA Perkins diesel generator application hotel commercial

Sararin Tattaunawa na OEM

Jiuan Generator ya ba mu tsari na kariya ta hanyar OEM don CDP200KVA Perkins 1100 TAG3 generator . Amsu na ƙarfin da suka kasance a matsayin kuma yanzu suna da canopis na gaba mai tsoro, formati na 20ft mai ƙarfi, ATS mai ƙarfi na ƙarfin da aka saita, tanki na kudin abinci na gaba, 4G IoT mai ƙarfi na ƙarfin da aka saita ta hanyar fara kuma tare da bayani na wadanda suka yi a lokacin da aka saita kuma bayani na kudin abinci, ƙarfin da ba su da kyauta (380V/220V, 415V/240V, ko wani da ke so), kuma LOGO na al'ummar da suka saita. Duk wani daga cikin wadannan suna da kuma amsu na Perkins 1106A-70TAG3 da suka shiga a matsayin asali kuma suna da kuma amsu na SGS da suka yi a faburin da suka yi a lokacin da suka yi a matsayin kuma a saka.

200KVA Perkins diesel generator

CDP200KVA shi ne maki na jiuan wanda ake amfani da shi don samun kari na 200KVA ta Perkins wanda aka tsara don amfani na al'ada na gida, kuma don amfani na yadda ake nufin kari — hoteru, gida na ofis, gida na bayani, da gida na sana’a na wasu daga cikin gida na sana’a. Ya ke da kari na Perkins 1106A-70TAG3 wanda ya ke da tashin kari na air-to-air aftercooled turbocharged induction, kuma ya ba da 144KW ISO8528 PRP don amfani na al'ada ta hanyar kari mai zama daidai kuma 160KW ESP don amfani na yadda ake nufin kari don tabbatarwa. Ya kammala EU Stage II don fuskantar kari. Ilimi na silent canopy ya kammala ≤75dB(A) a 7m; DSE6120 AMF auto-start wanda ya ke da ATS transfer a cikin ƙarshe na 10 seconds. Tanki na kari na 400L ya taimaka don 8–9 hours na amfani mai sauƙi.

Nemi Farashi

Wanrranty da Kwalin Aiki

Matsalar Aminci

Matsalar Aminci

1 sanan ko 1000 saati

Garanti Mai Zurfi

Garanti Mai Zurfi

Za a iya samun 3 sanan don Perkins engines;
2 sanan don Stamford S-series alternators

Global After-sales

Global After-sales

Taimako na teknikal na mutumin gaskiya da shugaban kantin na kwayoyin da ke aiki

Mun faruwa da muna da gaskiya

Kariya da Sertipikit na dacewa

Kariya da Sertipikit na dacewa

Duk generator mu suka yi aiki da karamar kiyayi na kiyayi da karamar kiyayi na kiyayi: CE, ISO 9001, ISO 8528, BV, SASO, da sauran su, wanda ke nuna cewa ya dacewa da kiyayi na kiyayi da kiyayi na kiyayi da kiyayi na kiyayi na kiyayi na kiyayi.

Kariya mai zuwa da kariya mai sauƙi da kariya mai zuwa da kariya mai sauƙi

Kariya mai zuwa da kariya mai sauƙi da kariya mai zuwa da kariya mai sauƙi

Ƙarfin wutar lantarki: Daga 20kVA zuwa 5000kVA (5MW).
Matsayin: Mu ba da Open, Silent, Super-Silent, Mobile (Trailer), Containerized, da High-Voltage generator sets. Duk wani ne iya tabbatawa don yadda kuke so (yadda na tsanen, yadda na gaba, da sauransu).
Kashe da shugaban kariya

Kashe da shugaban kariya

Mun yi amfani da ƙwararren al'umma na duniya don duk abubuwan da suka fiye:
Mashin: Cummins, Perkins, Volvo, Mitsubishi, Weichai, Baudouin
Matsayin kafin daidai: Stamford, Leroy Somer
Matsayin: Deepsea, ComAp, Smartgen
Sauran da taimaka ga ayyukan

Sauran da taimaka ga ayyukan

Mai taka da ku a cikin shugaban kari:

Genset mai tabbata: ba ta ci gaba, ba ta ci gaba a cikin gida, yadda na tabbata

Takon bayani na teknoliji na kowane ayyuka da takon ganin a cikin jihadi

Ƙarin tarin aiki: takaddun data, kofin kore, kofin kwayoyi, ƙayyade

hotline na Genset na 24/7: +86 18818906850

Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China

Kuma amsa mai kyau da ƙarfi, yana da kuma tabbali.

Kunna Mana

Samu Kyautar Kyauta

Wakilinmu zai tuntube ku nan ba da jimawa ba.
Imel
Mota/WhatsApp
Sunan
Sunan Kafa
Saƙo
0/1000