Ọnọr Ọkachamara
otu afọ ma ọ bụ 1000 hours
CDP200KVA bụ ịkụ ọkụ diesel 200KVA nke Jiuan Generator na-eme ihe nke e nwere ike iji mee ihe dịka ihe nke ọkụ nke ụlọ ọrụ ma ọbụ ihe nke ọkụ nke ọzọ — ụlọ ọrụ, ụlọ ọfice, ụlọ ịkwu ọrụ, na ụlọ ọrụ ndị ọzọ nke ukwuu. Nke a na-akpọ ọkụ nke Perkins 1106A-70TAG3 na-akpọ ọkụ nke air-to-air aftercooled turbocharged induction, ọ na-akpọ ọkụ 144KW ISO8528 PRP nke ọkụ nke ọzọ maka ọkụ nke ọzọ nke ọgụgụ ọhụrụ ma ọbụ 160KW ESP nke ọkụ nke ọzọ maka ọkụ nke ọzọ nke ọgụgụ ọhụrụ. E nwere ike ịkpọ ọkụ EU Stage II. Ihe nke ọkụ nke ọzọ nke silent canopy nke e nwere ike ịkpọ ọkụ ≤75dB(A) na 7m; DSE6120 AMF auto-start na ATS transfer nke e nwere ike ịkpọ ọkụ nke ọzọ nke ọgụgụ ọhụrụ nke ọgụgụ ọhụrụ. Ọkụ nke 400L na-akpọ ọkụ 8–9 hours nke ọkụ nke ọzọ.
CDP200KVA bụ nke Jiuan Generator 200KVA Perkins diesel generator e mere maka ụlọ ahịa hotels, resorts, ụlọ ahịa, ụlọ ọrụ mmepụta ihe na ụlọ ọrụ ụlọ ọrụ nke chọrọ ike na-aga n'ihu na 144KW n'oge ọrụ azụmahịa na nkwado ndabere na-eguzosi ike n'ihe mgbe netwọk dara. Igwe ikuku na-ekpo ọkụ nke Perkins 1106A-70TAG3 na-ekpo ọkụ ikuku ikuku na-ekpo ọkụ tupu ọ banye n'ime ụlọ ọkụ, na-ebelata okpomọkụ ikuku site na ihe dị ka 150 ° C ruo 50 ° C na-abawanye njupụta nke ụgwọ, na-eme ka arụmọrụ ọkụ dịk Ihe si na ya pụta bụ 180KVA isi ike generator ikike nke 144KW nke TAG3 engine na-akwado na-aga n'ihu na-enweghị ike de-rating, na 500 awa zubere ọrụ etiti.
Ihe Perkins 1106A-70TAG3 genset engine bụ a isii cylinder, inline, anọ-stroke, mmiri-mmachi unit na 7.01L displacement, 105mm × 135mm oghere na strok, na a 16:1 mkpakọ ruru. Na-agba ọsọ na 1500 RPM (50Hz), ọ na-emepụta 144KW/180KVA isi ike maka iji azụmahịa na-aga n'ihu na 160KW/200KVA ike njikere maka nkwado mberede. Nhazi TAG3 jikọtara otu turbocharger iji kpokọta ikuku ikuku maka ịbawanye njupụta nke ụgwọ na ikuku ikuku na-eme ka ikuku kpoo ọkụ nke na-ekpochapụ okpomọkụ mkpakọ tupu ụgwọ ahụ erute na manifold ntinye oke okpomọkụ nke na-enye ohere ịrụ ọrụ zuru oke na ọnọdụ gburugburu ebe obibi Igwe ahụ kwekọrọ na ụkpụrụ EU nke abụọ nke ikuku, na-akwado mbubata ọrụ azụmahịa, ntinye akwụkwọ nke ndị na-eme atụmatụ, na akwụkwọ nchekwa gburugburu ebe obibi na ahịa mbupụ. Mmanụ ụgbọala: 41.6 L/h na 100% isi ibu, 31.8 L/h na 75% isi ibu, 20.1 L/h na 50% isi ibu.
Asambodo ISO8528 na-ekpuchi nhazi ọrụ abụọ maka CDP200KVA. Nhazi PRP (144KW/180KVA) na-egosi na otu a bụ 180KVA isi ike generator maka ọrụ na-enweghị njedebe dị ka isi iyi nke ike nke ụlọ ọrụ, ma ọ bụrụ na ọnụọgụgụ nke ibu ọrụ na-anọ n'okpuru 70% n'oge elekere 24 ọ bụla nhazi nke a na-etinye na ụlọ oriri na ọṅụṅụ na ụlọ ahịa azụmahịa na-eji CDP200KVA dị ka isi ọkọnọ n'oge grid Nhazi ESP (160KW/200KVA) na-egosi na unit ahụ bụ 200KVA standby generator set maka nkwado ndabere na mberede nke nrụpụta ike, na obere oge oke ibu n'ime oge elekere 12 ọ bụla maka ọkụ ọkụ na-abanye na mmalite. A na-enye akwụkwọ asambodo CE nke na-ekpuchi ISO8528, klaasị mkpuchi nke alternator, na nnabata nke EU Stage II engine na nkeji ọ bụla maka ị nweta azụmahịa mba ụwa.
Alternator nke ọ dịghị brushless na-eme ihe nke synchronous nke eji H-class insulation, na-eme ihe nke IP23 base protection (IP55 bụ ihe nke e nwere ike ịhụ), na-eme ihe nke vacuum-impregnated full-copper windings, na-eme ihe nke digital AVR nke nwere ike ịkpọ mgbe ọ dị na voltage na ±1% na THD nke dị n’okpuru 5% — ihe nke a na-achọ maka HVAC systems nke dị na hospital, electronic POS terminals nke dị na ahịa, server infrastructure, na ihe nke dị na kitchen. Na Perkins 1100 TAG3 generator , Jiuan Generator nwere ike ịbụ Deep Sea DSE6120 ma ọ bụ SmartGen HGM6120 controller, nke nwere ike ịmata ihe nke automatic mains failure (AMF), auto start-stop, ATS transfer nke dị n’okpuru 10 seconds, na real-time monitoring nke phase voltages, currents, frequency, power factor, oil pressure, coolant temperature, na accumulated run hours. RS485 communication bụ ihe nke dị na ala; 4G remote monitoring nke dị n’okpuru nwere ike ịmata status site nke ọ bụla nke dị na network. Ihe nke nwere ike ịkụzị ihe nke ọ dịghị mma bụ high coolant temperature, low oil pressure, overspeed, undervoltage, short-circuit, na overload shutdowns.

| Oke | Uru |
| Mọdelu | CDP200KVA |
| Ihe ndị dị mma nke na-eme ka ọ dị mma | 144KW / 180KVA |
| Ọkụ ọgwụ | 160KW / 200KVA |
| Mọdelụ ọgbụgbọ ejiri | Perkins 1106A-70TAG3 |
| Ihe nke ịdị ọcha | 7.01L |
| Cylinders | 6 Inline |
| Bore × Stroke | 105mm × 135mm |
| Ụlọ mmiri nchepu | 16:1 |
| Ihe Nkọwa | Turbocharged + Air-to-Air Aftercooled |
| Uru Nke Nkọwa | EU Stage II |
| Nkọwa Nke Oke Oke | -10°C nke ọ dị na-eme ihe |
| Ịgbakwunye Ebele @ 100% | 41.6 L/h |
| Ịgbakwunye Ebele @ 75% | 31.8 L/h |
| Ịgbakwunye Ebele @ 50% | 20.1 L/h |
| Ihe ọmụma ahụ / Ihe ọmụma ahụ | 50Hz / 1500RPM; 60Hz / 1800RPM |
| Phase / Wires | 3-Phase, 4-Wire |
| Igwe Voltage | 400/230V, 415/240V, 380/220V |
| Ọdịnaya nkwere | 0.8 Lagging |
| Nweta | 12V DC Electric Start |
| Ọnụaha | Deep Sea DSE6120 / SmartGen HGM6120 |
| Alternator | Stamford / Leroy-Somer / Tooplinks |
| Isi Insulation | Isi H |
| Ịgụnọ Ịgụnọ | IP23 standard / IP55 nke dị mkpa |
| Nzuzo Dịka | ≤75dB(A) @ 7m |
| Ụlọ nke ọkụ | 400L (8–9 oru n’ime ọkụrụ) |
| Dimensions (L×W×H) | 3600 × 1350 × 2000mm |
| Ibu | 2,200kg |
| Ọ dị ka ha | ATS Transfer Switch, 4G IoT Module, Containerized Format |

1. Air-to-Air Aftercooling — Thermal Margin at Full Prime Load for 24/7 Commercial Operations
Nkọwa "TAG3" na-egosi na ọ dị mma maka air-to-air aftercooled induction on the Perkins 1106A-70TAG3 genset : aftercooler na-ewepụ ọkụ nke turbocharger compression bẹe n’ime cylinders, na-akụzi temperature nke charge air site na 100°C mgbe ọ dị ka non-aftercooled turbocharged configurations. Temperature nke combustion nke dị nta na-akụzi thermal stress nke cylinder head, piston crown, na exhaust valves — na-akwado TBO (time between overhaul) nke generators nke na-aga n’ime prime duty nke ọdịda na-eme ihe nke 8–16 oru nke ọtụtụ ụbọchị bụ ihe nke dị mkpa. Nke a bụ ihe nke na-akpata na TAG3 na-achọ 144KW site na 7.01L mgbe ọ dị ka 108KW nke non-aftercooled 1106A-70TG1 site na otu displacement.

2. Ọkwa nke EU nke abụọ Nkwekọrịta nke Ọrụ Azụmaahịa Mba Nile
Perkins 1106A-70TAG3 engine na-emezu EU Ọkwa II mobile igwe emission ókè maka particulate ihe na nitrogen oxides, na-akwado mbubata asambodo, gburugburu ebe obibi mmetụta ntule n'ihu na obodo ọchịchị atụmatụ akwụkwọ maka 200KVA Perkins diesel generator na mmepe ụlọ ahịa azụmahịa na EU, Africa, Ndịda Ebe Ọwụwa Anyanwụ Eshia, na Middle East. Jiuan Generator na-enye asambodo ntinye ọkụ dị mkpa na nkeji ọ bụla maka itinye ya na ngwugwu nnabata ọrụ.
3. Ihe ndị dị mkpa. 144KW ISO8528 PRP Full Prime Duty na-enweghị obere oge
ISO8528 PRP (144KW/180KVA) na-egosi na 180KVA isi ike generator ka ọ dịrị iru nke ọ bụla na mgbakwunsi nke ọ bụla na ihe atụ nke oge nke ebe ahụ — ọ dị iche na ESP ratings, ọ bụla na oge nke 12 oru. Ka ngalaba ụlọ ọgwụ, ngalaba ọrụ, na ngalaba ịkpata ihe ọ bụla nke CDP200KVA dị ka ihe nke ọ bụla nke ha na-eme na oge nke ọ dị ọkụkụ ma ọ bụ na ebe ọ dịghị ihe ọ bụla nke ọ bụla, PRP certification na-ekwe omume na output nke 144KW bụ ihe nke ọ dịrị iru nke ọ bụla na mgbakwunsi nke ọ bụla mana ọ ghara inwe ihe nke ọ bụla ma ọ bụ oge nke ọ bụla.

5. DSE6120 AMF Auto-Start — Ihe nke ọ dịrị iru nke ọ bụla na ihe nke ọ bụla nke ngalaba ọrụ nke ọ bụla
Ihe nke Deep Sea DSE6120 controller's automatic mains failure (AMF) function na-achọ ihe nke ọ bụla nke grid ma ọ bụ ihe nke ọ bụla nke ọ bụla na-akpata ihe nke ọ bụla nke ọ bụla na-akpata ihe nke ọ bụla nke ọ bụla 200KVA standby generator set , na-emecha nnyefe ike n'ime ihe na-erughị sekọnd 10 oge nnyefe nke ọtụtụ UPS azụmahịa na-achọ na usoro nchebe dị oke mkpa maka CCTV ụlọ nkwari akụ, njikwa nnweta kọmputa, sistemụ POS, friji, na ụlọ IT. DSE6120 na-enyochakwa voltaji na ọkụ nke oge ọ bụla, na-enye ohere ịchọpụta nrụrụ nrụrụ na-enweghị isi na bọọdụ nkesa atọ na ụlọ ahịa azụmahịa.

CDP200KVA 200KVA Perkins diesel generator a na-etinye ya na ngwa ahịa na ụlọ ọrụ mmepụta ihe ndị a na-esonụ:

Jiuan Generator pụtara ihe ọrụ nke OEM nke CDP200KVA Perkins 1100 TAG3 generator ihe ọrụ dị iche iche bụ: ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara, ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara, ihe ọrụ nke ATS nke eji eme ihe ọrụ nke ọkachamara, ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara, ihe ọrụ nke 4G IoT nke eji eme ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara, ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara (380V/220V, 415V/240V, ma ọ bụ ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara), na ihe ọrụ nke LOGO nke eji eme ihe ọrụ nke ọkachamara. Ihe ọrụ niile bụ ihe ọrụ nke Perkins 1106A-70TAG3 nke eji eme ihe ọrụ nke ọkachamara na ihe ọrụ nke SGS nke eji eme ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara nke eji eme ihe ọrụ nke ọkachamara.
CDP200KVA bụ ịkụ ọkụ diesel 200KVA nke Jiuan Generator na-eme ihe nke e nwere ike iji mee ihe dịka ihe nke ọkụ nke ụlọ ọrụ ma ọbụ ihe nke ọkụ nke ọzọ — ụlọ ọrụ, ụlọ ọfice, ụlọ ịkwu ọrụ, na ụlọ ọrụ ndị ọzọ nke ukwuu. Nke a na-akpọ ọkụ nke Perkins 1106A-70TAG3 na-akpọ ọkụ nke air-to-air aftercooled turbocharged induction, ọ na-akpọ ọkụ 144KW ISO8528 PRP nke ọkụ nke ọzọ maka ọkụ nke ọzọ nke ọgụgụ ọhụrụ ma ọbụ 160KW ESP nke ọkụ nke ọzọ maka ọkụ nke ọzọ nke ọgụgụ ọhụrụ. E nwere ike ịkpọ ọkụ EU Stage II. Ihe nke ọkụ nke ọzọ nke silent canopy nke e nwere ike ịkpọ ọkụ ≤75dB(A) na 7m; DSE6120 AMF auto-start na ATS transfer nke e nwere ike ịkpọ ọkụ nke ọzọ nke ọgụgụ ọhụrụ nke ọgụgụ ọhụrụ. Ọkụ nke 400L na-akpọ ọkụ 8–9 hours nke ọkụ nke ọzọ.
otu afọ ma ọ bụ 1000 hours
Nke ọzọ 3 afọ maka Perkins engines;
2 ọdụ maka Stamford S-series alternators
Nkọwa teknụkal nke ọrụ na ngwaọrụ ndị ọzọ nke ọrụ
Gensets nke ị chọrọ: nwere ike ịkpọ, enweghị ihe ịdị iche, nke ị chọrọ ihe ọ bụla
Nke ịrụ ya nke ihe kachasị mkpa na ịkpọ ọnụ ahịa nke ọzọ
Ihe ọ bụla nke e mechara: data centers, mines, ports, infrastructure
24/7 Genset Service Hotline: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Nkọwa ọhụrụ na ọ dị ịrịba ama bụ ihe ọ bụla e nwere ike ịgbanwe.