makina na kafin gurasa ta diesel na 275KVA

CDP275KVA shi ne generator na Jiuan da 275KVA wanda ake amfani da Perkins kuma ake amfani da shi don sauyin gida ta harka kuma don sauyin gida ta yanzu. Ya ke amfani da Perkins 1206A-E70TTAG3 wanda ya ke amfani da electronic governor don zama a cikin ±0.5% na frequency a lokacin da aka sauya load, wannan unit yana iya tsarawa da inductive loads wanda suka dace da lokacin da aka sauya gida — tower cranes, concrete batching equipment, compressors, da welding sets — ba tare da VFD trips da motor thermal faults wanda suka dace da frequency excursions na mechanical governor. ISO8528 PRP ya kawo 200KW/250KVA don amfani da shi a lokacin da aka sauya gida; ESP ya kawo 220KW/275KVA don amfani da shi a lokacin da aka sauya gida ta yanzu.

Nemi Farashi
  • Gafara

Gafara

Sakamun Na Kasar Gida: Tsarin 250KVA na Karama Ta Yau Da Yau

Ayyukan gine-gine gine-ginen gine-gine da yawa, ayyukan gine-gine, gyaran gine-ginen ma'adinai, da manyan masana'antu suna buƙatar janareta wanda ke sarrafa haɗuwa da haɗuwa da nauyin lokaci guda maimakon zane ɗaya. Gidan gyaran gyare-gyare na zamani tsakanin 30% da 75% na ƙarfin, kayan aiki na siminti da farawa da tsayawa, kayan aiki na welding da ke aiki a kan matakan da yawa, masu matsawa, da kuma ofishin HVAC na ofishin duk suna raba wannan motar mai samarwa kuma suna haifar da bayanin buƙata wanda ya bambanta a kowace awa a CDP275KVA 275KVA Perkins diesel janareta tana magance wannan cakuda kaya ta hanyar mai sarrafa lantarki na Perkins 1206A-E70TTAG3, wanda ke kula da yawan ciyarwa a cikin ± 0.5% a ƙarƙashin canje-canjen matakai na matakai kare masu sauyawar mita akan cranes da injina na

Injin janareta na Perkins 1206A-E70TTAG3 inline ne mai silinda shida, mai aiki hudu, mai sanyaya ruwa tare da 7.01L displacement, 105mm × 135mm bore da bugun jini, da kuma yanayin matsawa 15.8:1. Dual jerin turbochargers tare da iska-zuwa-iska bayan-sanyaya caji da konewa jam'iyya a densities cewa samar 220KW ganiya fitarwa daga 7.01L wani iko-to-displacement rabo cewa rike overall engine girma m dangane da mazan 812L single-turbo dandamali. Ƙarfin sanyi yana fadada zuwa -15 ° C ba tare da taimako ba, tare da zaɓin preheating na glow plug da ke rufe yanayin yanayi mai girma da yanayin yanayin aikin hunturu zuwa -25 ° C. An daidaita mai kula da lantarki don haɗuwa da nauyin haɗari da juriya, tare da amsawa mai sauri wanda ke guje wa saurin Amfani da man fetur shine 56.9L / h a cikakken nauyin kaya, 41.5L / h a 75% kaya, da 28.1L / h a 50% kaya; Tsakanin sabis shine awa 500.

Sertipikat ISO8528 yana kuma gaba daya na biyu na klasifikashin aiki. Sertipikat PRP (200KW/250KVA) yana nuna cewa CDP275KVA shi ne generator na gida na ayyukan bincike da ke da amfanin 250KVA don aiki mai tsoro wajen aiki na farko na gida na ayyukan bincike bayan ayyukan bincike na farko, kuma yayi aiki da yawa wajen aiki na farko na gida na ayyukan bincike bayan ayyukan bincike na farko. Sertipikat ESP (220KW/275KVA) yana nuna cewa abu na aiki shi ne sabis na amfanin 275KVA don aiki na gaba daya na kariya ta hanyar tsohon kariya bayan ayyukan bincike na farko ya faru — kuma yana da fahimtar amfanin yawa wajen aiki na gaba daya na kariya wajen 12 saati na kariya don aiki na farko na kariya. Suka sanya dukkanin sertipikat suka yi amfani da CE don aiki na mutum na gida, al’ummar da ayyukan bincike, da sertipikashin abubuwa.

Uku ƙararrun ƙararrun kuma suka yi amfani da farko na yankin da aka saita. Tsarin mai fuskaka ya zama mafi kyau don samun gudunmawa ta hanyar dukkanin tukunna na gida na maki, wanda ke cikin gida na maki na aminci. Kananan tsarin mai sokin rana (super silent canopy), wanda yana da tsawon sautin ≤75dB(A) a cikin 7 mita, ya zama mafi kyau don ayyin gida na urbana da yankin da suka dace da sautin ayyuka na gida. Tsarin mai kusar (containerized version) (20ft/40ft na farko da kuma da kusar na maki na gida na maki) ya zama mafi kyau don rarraba ayyin gida, wanda ke amfani da shi don gudunmawa na yankin, gudunmawa na farko na karama, da gudunmawa na farko na karama. Kusar na 400L na gida ya zama mafi kyau don 7–9 awa na gudunmawa ta hanyar karama, wanda ya zama mafi kyau don gudunmawa ta hanyar karama na rana da ranar asibiti.

Ya ƙara da alternator na synchronous mai gamsarwa wanda ya ƙara da insulation na Class H, ajiyar IP23 (ajiya IP55 zai iya zaɓa), da kuma windings na copper ta yanzu ta ƙara da vacuum-impregnated. Wani wannan generator na 275KVA na Perkins ya ƙara da controllers na Deep Sea DSE7320 ko SmartGen HGM6120 don ƙara da tsawo na phase voltage, current, frequency, power factor, oil pressure, coolant temperature da runtime. DSE7320 ya ƙara da tsawo na current na kowace phase, wanda ke taimaka ga technicians don gaba da balancing na three-phase loads kuma don gaskiya da overloads ko equipment trips wanda suka daga single-phase devices. ATS terminals na factory-wired da 4G remote monitoring na optional suna taimaka ga on-site start-stop control da real-time status checking.

275KVA Perkins diesel generator CDP275KVA construction site

Tsayar Goma

Paramita Ƙima
Samfur CDP275KVA
Kawai na wakilu 200KW / 250KVA
Kawai na kasa 220KW / 275KVA
Tsarin injin Perkins 1206A-E70TTAG3
Rarraba 7.01L
Cylinders 6 Na Tsaki
Bore × Stroke 105mm × 135mm
Compression ratio 15.8:1
Kurkurewa Dual Sequential Turbo + Aftercooled
Iyali na Governor Electronic, ±0.5% frequency deviation
Cold Start -15°C unassisted / -25°C with preheat
Fuel Consumption @ 100% 56.9 L/h
Fuel Consumption @ 75% 41.5 L/h
Karamin Kudin Zaki a 50% 28.1 L/h
Frequwansi / Saya 50Hz / 1500RPM; 60Hz / 1800RPM
Fasa / Kwayoyi 3-Fasa, 4-Kwayoyi
Voltage Output 400/230V, 415/240V, 380/220V
Fakar watsiya 0.8 Lagging
Yi shigo 12V DC Electric Start
Mai sarrafawa Deep Sea DSE7320 / SmartGen HGM6120
Madadin Stamford / Leroy-Somer / Tooplinks
Ƙungiyar rufi Class H
Takaddun Tattara IP23 standard / IP55 zai iya amfani da shi
Matsayin Gargajiya ≤75dB(A) a 7m
Tankin mai 400L (7–9 awat a yanzu na karama ta hagu)
Tsawon abu (L×W×H) 3600 × 1350 × 2000mm
Nauyi 2,700kg
Kawai ATS Transfer Switch, 4G IoT Module, Containerized Format

1206A-E70TTAG3 generator specifications

5 Tsarin Karamin Gaskiya

1. Electronic Governor ±0.5% Frequency Deviation — VFD da Motor-Heavy Site Load Compatibility
Kwararren da aji shi na site ya zama mai yawa daga wani inverter (VFD) a cikin tower cranes, concrete pumps, da HVAC compressors suka buƙatar governor na generator wanda ya zama mai amfani da step-load changes ba tare da frequency excursions ba wanda suka haɗa VFD fault protection ko motor thermal protection relays ba. The Perkins 1206A-E70TTAG3 generator governor na elektronik na shi ya kawo supply frequency a cikin ±0.5% deviation a lokacin step-load events — wani specification wanda ya tsara nuisance VFD trips da motor controller faults a construction site distribution boards inda inductive load switching ya zama mai yawa a cikin kowace working shift.

275KVA Perkins diesel generator electronic governor

2. -15°C Unassisted Cold Start — Rabi da Kudin Gwamnati na Winter da High-Altitude Project Site
Halin matsawa na 15.8: 1 da yanayin konewa na 1206A suna tallafawa amintaccen sanyi farawa a -15 ° C ba tare da preheating na shigarwa ko taimakon farawa ba rufe yawancin yanayin yanayin aikin aikin hunturu daga ayyukan ababen more rayuwa na arewa zuwa manyan ayyukan hanyar shiga ma'adinai. Zaɓin preheating na fitilar haske yana ba da tabbacin ƙonewa zuwa -25 °C don yankunan permafrost da yanayin gini na dutse inda rashin fara janareta a cikin yanayin sanyi yana haifar da jinkirin shirin. Ana gwada aikin sanyi-farawa bisa ga ISO8528-5 a cikin yawan zafin jiki na aiki.

3. Ka yi tunani a kan wannan. Tsarin kwantena + hanyoyin hawa Ana iya canzawa yayin da shirin gini ya ci gaba
CDP275KVA mai kwantena, wanda ake samu a cikin nau'ikan 20ft ko 40ft, ya haɗa da aljihunan tashar forklift da aka gina a cikin tsarin tushe don jan-girbi ko sake sanya forklift yayin da shirin aikin ya ci gaba. A Ƙungiyar Perkins 1200 wanda za su iya tabbatawa a cikin wani yanki ta hanyar telehandler — daga kishin yanki na gaba har zuwa jihun da ke cikin yankin elektriko na halin da aka fara shi har zuwa jihun da ke cikin yankin da ke cikin karamin halin da aka sanya — ya sao kamarin kwayoyin kafin da suka yi amfani da su kuma ya tsoro abin da ke nufin samun jihun da ke cikin generator na tsawon da zai kashe ko zai canzawa a cikin bantamai.

250KVA construction site generator containerized format

4. DSE7320 Nuna Kwayar Kwaya Ta Gaba — Tsarin Samun Kwayar Kwaya Don Samun Kwayar Kwaya Ta Muhallimin Da Su Ka Fara
Kontrola na Deep Sea DSE7320 ta nuna kwayoyin kwaya da kwayoyin kwaya ta gaba a kishin da ke gaba, wanda ya ba muhajirin na elektriko na halin da su nuna kwayar kwaya ta gaba a cikin kwayar kwaya ta gaba na halin da ke cikin kwayar kwaya ta gaba na halin da ke cikin kwayar kwaya ta gaba. Kwayar kwaya ta gaba daga kwayoyin kwaya ta gaba, kwayoyin kwaya ta gaba na kishin da ke cikin kwayar kwaya ta gaba, da kwayoyin kwaya ta gaba na kishin da ke cikin kwayar kwaya ta gaba suna ne da kwayar kwaya ta gaba na kwayar kwaya ta gaba na halin da ke cikin kwayar kwaya ta gaba — nuna kwayar kwaya ta gaba na DSE7320 ta nuna kwayar kwaya ta gaba kafin da ta zama kwayar kwaya ta gaba na kwayar kwaya ta gaba, kwayar kwaya ta gaba na kwayar kwaya ta gaba, ko kwayar kwaya ta gaba na generator.

5. Alama'in na Perkins 1206A da aiki da kuma yadda na 500-wata — Tsarin tsanin gaba daya a cikin wajen da ke aiki
Duk wani CDP275KVA ya dace da alama'in na Perkins 1206A-E70TTAG3 da aiki da kuma a dukkanin yanayi — sets na filtar, belts, injectors, da components na governor suka iya samun a cikin shugabancin tashin Perkins a Afrika, Asia ta Kudu-Kudu, da Najeran. Ya makina na kariya na 250KVA don gida Yadda na 500-wata na kariya na CDP275KVA zai iya haɗawa da tsarin yadda na aiki, don haka tsarin tsanin zai iya raba a lokacin da aka ci gaba da aiki, lokacin da suka ci gaba da aiki, ko lokacin da suka ci gaba da aiki kuma ba a lokacin da ke aiki da kariya ba saboda yadda na aiki da kariya zai iya haɗawa da kariya na aiki.

275KVA Perkins diesel generator maintenance service

Mai amfani daidai

CDP275KVA makina na kafin gurasa ta diesel na 275KVA yana a amfani da ita a cikin wadannan yanayin aiki da kariya na gida da kariya na aiki:

  • Gida na gida da gida na aikin kasa da kariya — kariya na gaba a lokacin da ke aiki da kariya na gida, yana canza zuwa kariya na gaba bayan da kariya na gida ta dace
  • Aikin kariya na kofa da kofa samar da wutar lantarki na wucin gadi ga tsarin hasken wuta, kayan aiki da kayan aiki, ofisoshin shafin da kuma tsarin kula da zirga-zirga
  • Kafa wurin hakar ma'adinai da kuma kayan aiki babban iko don shigarwa na kayan aiki kafin haɗin cibiyar sadarwa na dindindin ko shigar da tashar tashar.
  • Ginin masana'antu da masana'antu na ɗan lokaci babban iko a lokacin aikin gini, canzawa zuwa jiran aiki lokacin da dindindin shigarwa ke aiki

275KVA Perkins diesel generator application construction

Sararin Tattaunawa na OEM

Jiuan Generator yana samar da cikakken keɓancewar OEM don CDP275KVA 275KVA samar da wutar lantarki na wucin gadi . Siffofin da ake da su sun haɗa da tsarin kwantena tare da tashoshin forklift da ruwan sama, akwatin sauya atomatik na ATS, saka idanu na nesa na 4G IoT tare da lokacin gudu da rahoton matakin mai, LOGO na musamman da launi na canopy, da daidaitaccen ƙarfin lantarki / mitar. Dukkanin raka'a an haɗa su da ainihin sassan Perkins 1206A-E70TTAG3 kuma sun wuce cikakken kayan aikin SGS kafin a aika su.

makina na kafin gurasa ta diesel na 275KVA

CDP275KVA shi ne generator na Jiuan da 275KVA wanda ake amfani da Perkins kuma ake amfani da shi don sauyin gida ta harka kuma don sauyin gida ta yanzu. Ya ke amfani da Perkins 1206A-E70TTAG3 wanda ya ke amfani da electronic governor don zama a cikin ±0.5% na frequency a lokacin da aka sauya load, wannan unit yana iya tsarawa da inductive loads wanda suka dace da lokacin da aka sauya gida — tower cranes, concrete batching equipment, compressors, da welding sets — ba tare da VFD trips da motor thermal faults wanda suka dace da frequency excursions na mechanical governor. ISO8528 PRP ya kawo 200KW/250KVA don amfani da shi a lokacin da aka sauya gida; ESP ya kawo 220KW/275KVA don amfani da shi a lokacin da aka sauya gida ta yanzu.

Nemi Farashi

Wanrranty da Kwalin Aiki

Matsalar Aminci

Matsalar Aminci

1 sanan ko 1000 saati

Garanti Mai Zurfi

Garanti Mai Zurfi

Za a iya samun 3 sanan don Perkins engines;
2 sanan don Stamford S-series alternators

Global After-sales

Global After-sales

Taimako na teknikal na mutumin gaskiya da shugaban kantin na kwayoyin da ke aiki

Service & Quality Guarantees

Wani abu da ke cikin kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi — a wajen da ke cikin ƙarfi da a wajen da ke cikin ƙarfi.

PICC-Insured Extended Warranty

Takardun da yawa ta 2 shekara ko 2,000 awa (wanda ya gabata), ta hanyar tashin PICC — wanda ya ba al'umma na gaba daya kai tsaye a dukkan abin da ke cikin.

abubuwan da suka daga duniya duk da yanzu a shekara 3 zuwa 5

Sauya mai kyau na gaba daya — abubuwan da suka yi takardun da yawa suka zo a dukkan al'umma a kowane 3 zuwa 5 rana, wanda ya ci gaba da kai tsaye a dukkan abin da ke cikin.

Premium Canopy Craftsmanship

Abubuwan da suka yi kai tsaye suna amfani da steel ta cold-rolled, powder coating ta high-gloss da insulation ta flame-retardant don kariya mai kyau na rust, scratch da kariya mai kyau na karya.

100% Authentic & Load-Tested

Duk wani abu shine ta farko da ESN ta maimuna da kariya, kuma duk wani generator ya taka da kariya ta full-load da overload tests a baya da sauya.

Extreme-Environment Configurations

Kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi, wajen da ke kusa da ƙarfi, da wajen da ke cikin ƙarfi na amfanin; suna haɗa da kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi, kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi, da kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi.

One-Stop Customs Clearance

Taimaka da kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi da kwamitin da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi ta hanyar da suka haɗa da kuma yadda za a yi amfani da su a wajen da ke cikin ƙarfi da wajen da ke cikin ƙarfi.

Kitabun da Bayanin Ingilishi da Taimaka

Shigar da dukkan bayanan, tabbatar da dukkan abin da ke cikin — kuma sauya da kai tsaye.

3D Exploded Views & Anti-Counterfeit Detail

Dukkare suna da kuma 3D rendered exploded views da close-up anti-counterfeiting shots na spare parts, wanda ke ba da imkanin mai amfani na ingilishi in sanya dukkan bayanan teknikal kamar yadda suka yi amincewa na CAD drawings.

Verifiable Materials & Workmanship

Ko'omar ta hanyar stator ya kashe kamar yadda za a iya ganin copper winding mai tsoro don tabbatarwa, kuma vernier caliper ta sukuri 2.5 mm cold-rolled steel sheet — wanda ke nuna abin da aka amfani da shi, ba kuma hanya na fassara ba.

Kitabun da Sa'uyin da Amsa Kammal

Kwayoyin da kwayoyin amfani na gaba daya da kwayoyin amfani na tattaunawa. Kitabun da yawa ta 150 shafu na bayanin sauyin amsa a uku harshe, bayanin tsarin kafa da kafa da CD ta da bayanin fassara na 3D ya zama babban tushen sauyin da sauyin amsa ga al'umma na gaba daya.

Mun faruwa da muna da gaskiya

Kariya da Sertipikit na dacewa

Kariya da Sertipikit na dacewa

Duk generator mu suka yi aiki da karamar kiyayi na kiyayi da karamar kiyayi na kiyayi: CE, ISO 9001, ISO 8528, BV, SASO, da sauran su, wanda ke nuna cewa ya dacewa da kiyayi na kiyayi da kiyayi na kiyayi da kiyayi na kiyayi na kiyayi na kiyayi.

Kariya mai zuwa da kariya mai sauƙi da kariya mai zuwa da kariya mai sauƙi

Kariya mai zuwa da kariya mai sauƙi da kariya mai zuwa da kariya mai sauƙi

Ƙarfin wutar lantarki: Daga 20kVA zuwa 5000kVA (5MW).
Matsayin: Mu ba da Open, Silent, Super-Silent, Mobile (Trailer), Containerized, da High-Voltage generator sets. Duk wani ne iya tabbatawa don yadda kuke so (yadda na tsanen, yadda na gaba, da sauransu).
Kashe da shugaban kariya

Kashe da shugaban kariya

Mun yi amfani da ƙwararren al'umma na duniya don duk abubuwan da suka fiye:
Mashin: Cummins, Perkins, Volvo, Mitsubishi, Weichai, Baudouin
Matsayin kafin daidai: Stamford, Leroy Somer
Matsayin: Deepsea, ComAp, Smartgen
Sauran da taimaka ga ayyukan

Sauran da taimaka ga ayyukan

Mai taka da ku a cikin shugaban kari:

Genset mai tabbata: ba ta ci gaba, ba ta ci gaba a cikin gida, yadda na tabbata

Takon bayani na teknoliji na kowane ayyuka da takon ganin a cikin jihadi

Ƙarin tarin aiki: takaddun data, kofin kore, kofin kwayoyi, ƙayyade

hotline na Genset na 24/7: +86 18818906850

Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China

Kuma amsa mai kyau da ƙarfi, yana da kuma tabbali.

Kunna Mana

Samu Kyautar Kyauta

Wakilinmu zai tuntube ku nan ba da jimawa ba.
Imel
Mota/WhatsApp
Sunan
Sunan Shiga
Saƙo
0/1000