350kva-perkins-diesel-generator-, 350kva-perkins-diesel-generator-, /perkins
Ajuju
350kva-perkins-diesel-generator-, 350kva-perkins-diesel-generator-, /perkins
Ajuju

350KVA Perkins diesel generator nke ịdị ọcha

CDP350KVA bụ Perkins diesel generator nke Jiuan Generator nke 350KVA maka quarry, aggregate, na ihe ngosi nke ihe dị elu nke ihe ngosi. E nwere ike ya site na Perkins 2206C-E13TAG2 — nke eji isi 6, 12.5L EUI diesel na G3-class electronic governing (±0.25% steady-state frequency) na 16.3:1 compression ratio — ihe a na-eme 280KW/350KVA ISO8528 PRP prime na 320KW/400KVA standby. 4300×1600×2250mm / 3500kg; ≤75dB(A) na 7m; 10-12h full prime tank autonomy; EU Stage II / EPA Tier 2; 18-month warranty.

Gbasara Akwụkwọ
  • Nchịkọta

Nchịkọta

280KW Quarry na Industrial Prime Power — Perkins 2206C-E13TAG2 EUI G3 Electronic Governing

CDP350KVA bụ nke Jiuan Generator 350KVA Perkins diesel generator nke ịdị ọcha na ọrụ quarry, ọrụ nke ịkpata ihe, mpaghara nke ịmepụta ihe dị ukwuu, na mpaghara ndị ọrụ ndị ọzọ ebe 280KW ISO8528 PRP prime power ga-eme nke ọma n’ime ọrụ nke ọtụtụ oge. Nke a na-enye ya site na Perkins 2206C-E13TAG2 na G3-class electronic governing na EUI fuel injection, CDP350KVA na-enye 280KW/350KVA prime na 320KW/400KVA standby — nke dị na 4300×1600×2250mm, 3500kg installation maka generator room nke dị n’ụlọ nke ọzọ na containerized site deployment.

Ihe Perkins 2206C-E13TAG2 genset engine bụ a isii cylinder, turbocharged na ikuku na ikuku intercooled dizel na 12.5L displacement, 130mm × 157mm oghere na ije, na 16.3:1 mkpakọ ruru. Electronic unit injection (EUI) na G3 klas electronic na-achịkwa na-enye steady-state ugboro mmezi n'ime ± 0,25% a mma ndidi karịa n'ibu ọchịchị usoro na-agafe agafe ugboro mgbake na-erughị 10 sekọnd mgbe a 60% nzọụkwụ ibu mgbanwe. Nkọwapụta a na-echebe ndị na-agba ọsọ ọsọ na ndị na-echebe moto na-agba ọsọ na-agba ọsọ na-agba ọsọ na-agba ọsọ na-agba ọsọ na-agba ọsọ site na njem na-akpata nsogbu n'oge usoro mmepụta.

Ihe 280KW ụlọ ọrụ mmepụta ihe isi generator CDP350KVA brushless synchronous alternator na-enye ike 400V/50Hz atọ-adọ ọkọnọ na voltaji iwu n'ime ± 1% na THD n'okpuru 1.5% n'ime harmonic ndidi nke crusher draịva, PLC akara ogwe, na ike na-akpata mgbazi The alternator si transient ibu ike aka inrush aga site kpọmkwem-on-line ndinuak moto amalite a elu-ugboro ugboro ọrụ omume na quarry na aggregate saịtị n'oge mgbanwe mmalite cycles. Ọ bụ ọkwa EU II / EPA Tier 2 gbaara akwụkwọ.

Ihe igwe na-emepụta ike nke 350KVA CDP350KVA dị na oghere oghere, super silent canopy (≤75dB ((A) na 7m), na ọnọdụ ikuku na-eguzogide mmiri. Nhọrọ a na-etinye na akpa na-enye arụmọrụ mmiri ozuzo, uzuzu, na corrosion na-eguzogide ọgwụ maka ihu oghere, ebe nchekwa mkpokọta, na ebe dịpụrụ adịpụ na-arụ ọrụ ịnweta ihe. Nnukwu tank mmanụ ụgbọala nwere ike ịkwado awa 10-12 nke ọrụ zuru oke na-ekpuchi ọrụ mmepụta zuru oke na-enweghị nkwụsịtụ na-agbanye mmanụ n'etiti ọrụ.

Ihe Perkins 2200 usoro genset Enjin CDP350KVA 2206C-E13TAG2 bụ enjin dị na ngwaọrụ Perkins-authorized service centres na Afrika, Middle East, South Asia, Southeast Asia, na Latin America — ihe ọzọ nke eji eme ihe ọkụrụ na ihe ọkụrụ nke ọkụrụ. Ihe ọkụrụ nke ọkụrụ na-eme n’ihe ọkụrụ nke 500-hour oil na filter bụ ihe ọkụrụ nke eji eme ihe ọkụrụ nke aggregate plant na quarry sites. Anti-vibration mounts na steel base frame nke ọkụrụ dị ọkụrụ ka e mezie ihe ọkụrụ nke ọkụrụ. Jiuan Generator pụtara warranty nke 18 months ma ọ bụ 2,000-hour na ọkụrụ CDP350KVA.

350KVA Perkins diesel generator CDP350KVA quarry prime power

Ntuziaka Teknisian

Oke Uru
Mọdelu CDP350KVA
Ihe ọkụrụ nke Prime Power (PRP) 280KW / 350KVA
Ihe ọkụrụ nke Standby Power (ESP) 320KW / 400KVA
Mọdelụ ọgbụgbọ ejiri Perkins 2206C-E13TAG2
Cylinders 6 Inline
Ihe nke ịdị ọcha 12.5L
Bore × Stroke 130mm × 157mm
Ụlọ mmiri nchepu 16.3:1
Sistimu Nkụrụ Nkụ EUI (Nkụrụ Elektronik Nke Unit)
Iguzi G3 Iguzi Elektronik
Ihe Nkọwa Turbocharged + Intercooler Nke Air-to-Air
Uru Nke Nkọwa EU Stage II / EPA Tier 2
Ihe ọmụma ahụ / Ihe ọmụma ahụ 50Hz / 1500RPM; 60Hz / 1800RPM
Phase / Wires 3-Phase, 4-Wire
Igwe Voltage 415/240V, 400/230V, 380/220V
Ọdịnaya nkwere 0.8 Lagging
Voltage regulation ±1%
THD <1.5%
Nweta 12V DC Electric Start
Ọnụaha DSE7320 / EMCP4.4
Alternator Stamford / Leroy-Somer / Tooplinks
Isi Insulation Isi H
Ịgụnọ Ịgụnọ IP23 standard / IP55 nke dị mkpa
Nzuzo Dịka ≤75dB(A) @ 7m (silent canopy)
Dimensions (L×W×H) 4300 × 1600 × 2250 mm
Ibu 3,500 kg
Ụlọ nke ọkụ Nke eji gburugburu (10–12 oru nke ọma nke ihe na-eme)
Ọ dị ka ha ATS Cabinet, 4G IoT, Containerized Housing

Perkins 2206C-E13TAG2 genset specification

5 Ihe Ndị Ọzọ Na-eme ka Ọ dị mfe

1. G3 Electronic Governing — ±0.25% Steady-State Frequency for Industrial VFD Circuits
Ihe 280KW ụlọ ọrụ mmepụta ihe isi generator CDP350KVA Perkins 2206C-E13TAG2 G3 electronic governor holds steady-state frequency within ±0.25% and recovers from transient deviation in under 10 seconds following a 60% step load — protecting variable-speed drives on conveyor feeds, crusher circuits, and industrial processing equipment from frequency excursions that trigger overcurrent protection.

280KW industrial prime generator G3 electronic governing

2. EUI Fuel Injection — Precise Load Response Across Variable Industrial Loads
Ihe Perkins 2206C-E13TAG2 genset EUI (Electronic Unit Injection) system precisely meters fuel delivery according to real-time engine load and speed demand — reducing smoke transients at crusher motor starts and improving fuel economy during partial-load intervals between production cycles, compared to mechanically governed engines of equivalent displacement.

3. Ihe ndị dị mkpa. 14.3% Standby Headroom Inrush Buffer n'elu Prime Rating
Ihe 350KVA Perkins diesel generator nke ịdị ọcha CDP350KVA 320KW/400KVA standby rating na-enye 14.3% ike headroom n'elu 280KW isi rating zuru ezu iji banye na-abata ugbu a nke a kpọmkwem-on-line crusher ma ọ bụ nnukwu Compressor moto mmalite enweghị ala ugboro ugboro tripping ma ọ bụ voltaji sag nke na-ak

350KVA quarry power generator installation

4. Oge 10-12 nke tank Nchịkọta zuru ezu nke mmepụta-mgbanwe na-enweghị nkwụghachi
Ihe igwe na-emepụta ike nke 350KVA CDP350KVA nnukwu ikike jikọtara mmanụ ụgbọala tank ekpuchi a zuru mmepụta ọrụ na otu ndochi eliminating mid-shift refueling nkwụsị na n'ime ime obodo quarry ihu, aggregate osisi, na off-grid ịnweta ebe nhazi mineral ebe tankị ohere n'oge ọrụ awa egbochi mmepụta.

5. Oge ọrụ nke awa 500 Ọ dị n'usoro ihe omume nke ọrụ mmezi nke ebe a na-egwute nkume
Ihe Perkins 2200 usoro genset CDP350KVA 2206C-E13TAG2 engine bụrụ na ọ dị n’oge 500-hour oil na filter service intervals — ihe a na-eme ka ọ dị n’oge maintenance shutdowns n’ime quarry, mine, na aggregate plant sites. Ihe ndị Perkins 2200 series dị n’ala niile, ọ na-akwado ogologo oge maka scheduled na emergency maintenance.

Perkins 2200 series genset maintenance service

Ihe ndị a ga-eji mee ihe

CDP350KVA 280KW ụlọ ọrụ mmepụta ihe isi generator na-eji ya n’ihe ndị a:

  • Ọrụ quarry na aggregate — ihe na-eme ihe nke mbụ maka primary crushers, secondary crushers, na screening plants
  • Ụlọ ọrụ ndị na-eme ihe nke isi — ihe na-eme ihe nke mbụ maka production lines, compressor rooms, na process utilities
  • Ihe ndị dị mkpụmkpụ nke ebe ndị na-eme ihe nke isi — ihe na-eme ihe nke mbụ maka shopping centres, cold storage, na distribution hubs
  • Ebe ndị na-eme ihe nke isi nke dị n’elu igwe ike kachasị elu maka agwaetiti-mode maka ebe ndị na-egwupụta ihe na ebe ndị na-agwọta ihe na-abụghị netwọk
  • Ebe ndị a na-anọ arụ ụlọ ndị mmadụ ike kachasị maka ụlọ ndị nwere ọtụtụ ụlọ na-adịru nwa oge n'ime oge dị ogologo nke ọrụ ahụ

Ọrụ OEM ahaziri iche

Jiuan Generator na-enye OEM nhazi maka CDP350KVA Perkins 2206C-E13TAG2 genset . Nhọrọ ndị dịnụ gụnyere super silent canopy na agba RAL ahaziri iche, DSE7320 ma ọ bụ EMCP4.4 njikwa na nkwukọrịta dịpụrụ adịpụ, ụlọ nkwakọba ihe maka mkpọsa nkume na ebe a na-egwupụta akụ, ụlọ ọrụ ATS, modulu nlekota 4G IoT, na tank mmanụ Ngwaọrụ niile na-eji ezigbo akụkụ Perkins 2200 usoro ma gafee ụlọ ọrụ ọkụ ọkụ ọkụ zuru ezu tupu izipu.

350KVA Perkins diesel generator OEM configuration

FAQ

Q: Gịnị bụ ihe dị iche n'etiti CDP350KVA isi na njikere ratings?
A: 350KVA Perkins diesel generator nke ịdị ọcha CDP350KVA bụ nke a kpọrọ 280KW/350KVA ISO8528 PRP prime gbaara akwụkwọ maka ịrụ ọrụ na-aga n'ihu na-enweghị mmachi awa kwa afọ, na-eme ka ọ bụrụ klaasị ziri ezi maka nkume igwe nri na ike kachasị elu nke ụlọ ọrụ. 320KW/400KVA standby rating na-agbakwunye 14.3% headroom maka ihe omume moto inrush, mana ọnọdụ njikere bụ maka nchekwa mberede grid na-ejedebe awa ịgba ọsọ kwa afọ.

Ajụjụ: CDP350KVA nwere ike ijikwa mmalite nke igwe na-agbaji ọkụ?
A: igwe na-emepụta ike nke 350KVA CDP350KVA 320KW/400KVA njikere isi ụlọ na G3 electronic onye nchịkwa na-enye ugboro na voltaji kwụsie ike n'oge kpọmkwem-on-line moto mmalite. Maka moto 90-110KW nke na-amalite DOL, genset na-amịkọrọ 5-7x inrush ugbu a n'ime ikike ya na-agafe agafe na-enweghị obere ugboro ugboro ma ọ bụ na-akpaghasị akụrụngwa ndị ọzọ na-agba ọsọ na ebe a na-egwute nkume.

Ajụjụ: Ebee ka a pụrụ inweta akụkụ Perkins 2206C-E13TAG2 na ebe ndị dịpụrụ adịpụ?
A: Perkins 2200 usoro genset CDP350KVA na-eji akụkụ dị na ndị nkesa Perkins nyere ikike na Africa, Middle East, South Asia, na Southeast Asia mpaghara isi na-ewepụta ihe na-esi ísì ụtọ. A na-etinye ihe ndị na-agbanye mmiri, eriri, nzacha, na ihe ndị na-eme ka oyi dị n'ebe ahụ, na-akwado mmezi oge na-enweghị ogologo oge na-enye ọrụ na ebe ndị dịpụrụ adịpụ.

350KVA Perkins diesel generator nke ịdị ọcha

CDP350KVA bụ Perkins diesel generator nke Jiuan Generator nke 350KVA maka quarry, aggregate, na ihe ngosi nke ihe dị elu nke ihe ngosi. E nwere ike ya site na Perkins 2206C-E13TAG2 — nke eji isi 6, 12.5L EUI diesel na G3-class electronic governing (±0.25% steady-state frequency) na 16.3:1 compression ratio — ihe a na-eme 280KW/350KVA ISO8528 PRP prime na 320KW/400KVA standby. 4300×1600×2250mm / 3500kg; ≤75dB(A) na 7m; 10-12h full prime tank autonomy; EU Stage II / EPA Tier 2; 18-month warranty.

Gbasara Akwụkwọ

Nchịkọta & Serbis

Ọnọr Ọkachamara

Ọnọr Ọkachamara

otu afọ ma ọ bụ 1000 hours

Nchịkọta nke nchịkọta

Nchịkọta nke nchịkọta

Nke ọzọ 3 afọ maka Perkins engines;
2 ọdụ maka Stamford S-series alternators

Nchịkọta nke na-adị na mbụrụ obodo

Nchịkọta nke na-adị na mbụrụ obodo

Nkọwa teknụkal nke ọrụ na ngwaọrụ ndị ọzọ nke ọrụ

Ihe ngwọta nke dị mma nke anyị

Ihe ngosi nke ọrụ nke ọdịda na ọrụ nke ọdịda

Ihe ngosi nke ọrụ nke ọdịda na ọrụ nke ọdịda

A na-emepụta ndị na-emepụta ihe anyị niile n'okpuru njikwa njikwa dị oke mkpa ma nwee asambodo mba ụwa: CE, ISO 9001, ISO 8528, BV, SASO, wdg, na-eme ka usoro mkpuchi ngwa ngwa na ọrụ a pụrụ ịdabere na ya n'ụwa niile.

Ihe ngosi nke ọrụ nke ọdịda na ọrụ nke ọdịda

Ihe ngosi nke ọrụ nke ọdịda na ọrụ nke ọdịda

Ikpeazu: Site na 20kVA ruo 5000kVA (5MW).
Ụdị: Anyị na-enye Open, Silent, Super-Silent, Mobile (Trailer), Containerized, na High-Voltage generator sets. Ihe niile nwere ike ịkọwa ha na ọrụ gị n’akụkụ (voltage, frequency, na ndị ọzọ).
Ihe ngosi nke ọrụ nke ọdịda nke ọrụ nke ọdịda

Ihe ngosi nke ọrụ nke ọdịda nke ọrụ nke ọdịda

Anyị bụrụ ụmụnna n’ihe dị ka ụlọ ọrụ nke ọtụtụ oge na ala ụwa maka ihe niile nke akụkụ nke ọrụ:
Ihe nke ịkpọ ọrụ: Cummins, Perkins, Volvo, Mitsubishi, Weichai, Baudouin
Ihe nke ịkpọ ọrụ nke ịkpọ ọrụ: Stamford, Leroy Somer
Nke ịrụ ya: Deepsea, ComAp, Smartgen
Ihe ngosi nke Customization & Project Support

Ihe ngosi nke Customization & Project Support

Onye nke ị si ike na-eme ka ị dị mma:

Gensets nke ị chọrọ: nwere ike ịkpọ, enweghị ihe ịdị iche, nke ị chọrọ ihe ọ bụla

Nke ịrụ ya nke ihe kachasị mkpa na ịkpọ ọnụ ahịa nke ọzọ

Ihe ọ bụla nke e mechara: data centers, mines, ports, infrastructure

24/7 Genset Service Hotline: +86 18818906850

Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China

Nkọwa ọhụrụ na ọ dị ịrịba ama bụ ihe ọ bụla e nwere ike ịgbanwe.

Kpọ Mmiri Anyị

Nweta nkwupụta efu

Onye nnọchi anya anyị ga-akpọtụrụ gị n'oge adịghị anya.
Email
Mobile/WhatsApp
Aha
Aha Ụlọ Ọrụ
Ozi
0/1000