Ọnọr Ọkachamara
otu afọ ma ọ bụ 1000 hours
400kVA silent diesel genset nke eji Cummins 6ZTAA13-G2 inline 6-cylinder engine, 50Hz/400V, PF0.8, ezi uche ISO8528. Turbo aftercooled & electronic fuel injection, eji IP23 H-class brushless alternator. Soundproof canopy nke eji n’okpuru nke ọrụ na nke ịkpọ ọkụ, ọdịda ọkachamara na-eme ka ụlọ ọrụ na ebe ọ bụla dị mma na ọrụ nke ọma na ọrụ nke ọma.
CDC400KVA bụ nke Jiuan Generator 400KVA Cummins diesel generator cDC400KVA bụ otu nke jiuan generator nke eji chọpụta ihe dị ka ọnụ ọgụgụ maka oche ahịa pụrụ iche, oche medịkal nke mkpa, na oche medịkal nke univrsiti nke eji chọpụta ihe dị ka ọnụ ọgụgụ nke ọgụgụ nke 10 sekọndi maka oche nke eji chọpụta ihe dị ka ọnụ ọgụgụ, ICU nke eji chọpụta ihe dị ka ọnụ ọgụgụ, na ihe nke eji chọpụta ihe dị ka ọnụ ọgụgụ. Eji DCEC Dongfeng Cummins 6ZTAA13-G2 engine nke ezi uche chọpụta ihe dị ka ọnụ ọgụgụ, otu a na-eme 320KW/400KVA ISO8528 PRP prime na 352KW/440KVA standby, na CE na ISO8528 certification maka ihe nke eji chọpụta ihe dị ka ọnụ ọgụgụ maka oche medịkal nke eji chọpụta ihe dị ka ọnụ ọgụgụ.
Ihe Generator 6ZTAA13-G2 nke Cummins CDC400KVA na-enye ike isii-cylinder turbocharged na intercooled na 13L displacement, 130 × 163mm bore na stroke, 17: 1 mkpakọ ruru, Holset turbocharger, na PD elu-mgbali nfuli na GAC electronic ọchịchị. N'ime igwe a, ikike nke njide njide ruru 365KW na 1500RPM. Mmanụ ụgbọala a na-eji agba 192-194g/kWh na-arụ ọrụ zuru oke na-enye ego kachasị mma maka usoro mmega ahụike nke ụlọ ọgwụ na-arụ ọrụ na usoro nyocha nke ọrụ.
Ihe 352KW njikere ike generator CDC400KVA canopy e wuru site 3mm oyi-akpọrepu ígwè na abụọ oyi akwa epoxy zinc-ọgaranya mgbochi nchara mkpuchi na multi-oyi akwa ire ọkụ-retardant acoustic ụfụfụ, gosiri ≤72dB ((A) na 7m izute ụlọ ọgwụ campus na residential mpaghara Igwe mmanụ ụgbọala dị na 950L na-akwado ihe karịrị awa 8 na-aga n'ihu na-arụ ọrụ zuru oke n'oge ogologo oge grid, na Fleetguard atọ-nyocha nchịkọta na-agbatị oge 400-hour maka oge mmechi ụlọ ọgwụ.
Ihe otu ọkụ dị ụtọ nke 400KVA CDC400KVA nke ọkụ nke ọkụ na-eme ka ọkụ dị ụtọ nke H-class, na-eme ka ọkụ dị ụtọ nke ±1% na THD <3%, na-enye ihe ọkụ dị ụtọ nke oge ahụ maka MRI na CT scanning rooms nke hospital, ICU ventilators na ihe nke ịmata onwe onye ọ bụla, ihe nke ịmata oge nke operating theater, na ihe nke pharmacy automation nke dị ịrịba ama maka ọkụ nke dị ụtọ. DeepSea DSE7320 controller na-enye ihe nke ịmata oge nke ọkụ nke 3-6 seconds mgbe ọkụ nke grid pụtara — na-eme ka ihe nke ọkụ nke hospital nke dị ụtọ maka ihe nke ọkụ nke dị ụtọ maka ihe nke ọkụ nke dị ụtọ.
Ihe Cummins 400KVA industrial genset CDC400KVA nwere ESN (Nọmba Seriọl Ọkụ) nke ndị otu ụlọ ọrụ si gosi, na-eme iji ngwa ngwa nke ọkụ nke 0%-25%-50%-75%-nke ọkụ dị ukwuu na 110% nke ọkụ nke ọzọ bago na ọkụ ahụ. Video nke iji ngwa ngwa na akwụkwọ PDF nke iji ngwa ngwa ga-eme ka ọ bụla nke ndị a. Ihe nchịkọta nke CDC400KVA nwere ike ịbụ nke PICC (People's Insurance Company of China), nke na-eme ihe nchịkọta nke e nwere ike ịgosi maka ịzụlite nke ụlọ ọgwụ, na ngwa ngwa nke ọkụ nke ọzọ ga-abịa na ụwa niile n'ime 3-5 ụbọchị site na njikọ nke Cummins nke na-eme ihe nchịkọta.

| Oke | Uru |
| Mọdelu | CDC400KVA |
| Ihe ọkụrụ nke Prime Power (PRP) | 320KW / 400KVA |
| Ihe ọkụrụ nke Standby Power (ESP) | 352KW / 440KVA |
| Mọdelụ ọgbụgbọ ejiri | Cummins 6ZTAA13-G2 (DCEC) |
| Ihe nchịkọta nke Ọkụ nke Cummins | 365KW @ 1500RPM |
| Cylinders / Ihe ọkụ na-achọpụta | Inline 6 / 13L |
| Bore × Stroke | 130mm × 163mm |
| Ụlọ mmiri nchepu | 17:1 |
| Sistimu Nkụrụ Nkụ | PD High-Pressure + GAC Governor |
| Ihe Nkọwa | Holset Turbo + Air-Air Intercooler |
| Igwè ịrịba ike | 192–194g/kWh (full prime load) |
| Nkọwa Lube Oil | Fleetguard Triple Filter Assembly |
| Iguzi / Iguzi Nke Ebe Ozi | 24V DC; -15°C nke ọrụ (-32°C nke ọrụ nke e nwere ike itinye) |
| Ikwado / Ikwado Nke Oge Oso | 400hr nke oge iguzi / >15,000hr nke oge iguzi nke oso |
| Ihe ọmụma ahụ / Ihe ọmụma ahụ | 50Hz / 1500RPM; 60Hz / 1800RPM |
| Phase / Wires | 3-Phase, 4-Wire |
| Igwe Voltage | 415/240V, 400/230V, 380/220V |
| Ọdịnaya nkwere | 0.8 Lagging |
| Voltage regulation | ±1% nke na-adịghị ihe ọ bụla; THD <3% |
| Alternator | Stamford / Leroy-Somer / Tooplinks |
| Nkọwa ụlọ / Nkwado | Klas H / IP23 (IP55 nwere ike ịdị) |
| Nkọwa ụlọ | ishii 3mm; foam akustik; tanku ụgbọ ala 950L nke na-akpọ |
| Nchịkọtị / Nchịkọtị nke ọhụrụ | ≤72dB(A) @ 7m / -25°C ruo +48°C |
| Dimensions (L×W×H) | 4300 × 1600 × 2250mm / 4,200kg |
| Nkọwa nke ATS | 3-6 sekondi (nke dị mkpa) |
| Ntakiri | CE, ISO8528, GB/T2820 |

1. 6ZTAA13-G2 365KW nke a na-akwado / 192-194g/kWh — Ihe ọ bụla nke e nwere ike maka ngwaahịa nke ahụịsị na ngalaba nke ọgwụgwọ na ngalaba nke ọgwụgwọ
Ihe 400KVA Cummins diesel generator CDC400KVA 13L inline-6 na Holset turbocharger na PD high-pressure fuel injection na-eme ka ọ dị 365KW nke a na-akwado na 192-194g/kWh nke a na-akwado — ịbụ ihe nke na-achụso ọsọ nke ọrụ maka ngwaahịa nke ahụịsị nke na-akpọ ọrụ nke generator nke na-akpọ ọrụ nke ahụịsị na ngalaba nke ọgwụgwọ na ngalaba nke ọgwụgwọ.

2. 3mm Steel + 950L Tank + ≤72dB — 8+ Hour Emergency Coverage na Hospital Campus Noise Compliance
Ihe 352KW njikere ike generator CDC400KVA 3mm cold-rolled steel canopy na double-layer epoxy zinc-rich coating na multi-layer flame-retardant acoustic foam na-eme ka ọ dị ≤72dB(A) at 7m — na-akpọ ọrụ nke ahụịsị na ngalaba nke ọgwụgwọ na ngalaba nke ọgwụgwọ. 950L integrated base fuel tank na-eme ka ọ dị 8+ full-load hours during prolonged grid outages without refuelling.
3. Ọrụ nke ọdịnala nke copper nke ọdịnala nke ọdịnala ±1% / THD<3% — Ihe ọkachamara nke ihe ọkachamara maka MRI, ICU, na ngalaba nke ịgba ọsọ
Ihe otu ọkụ dị ụtọ nke 400KVA CDC400KVA nke ọdịnala nke copper nke ọdịnala H-class nwere ike ịgbanwe voltage nke ọdịnala nke ±1% na THD <3%, na-eme ka ọ dị mfe maka MRI scanners, CT imaging rooms, ICU ventilators na monitoring systems, operating theater precision instruments, na pharmacy dispensing automation. Ihe ọdịnala nke ọdịnala anaghị ekwe omume ịkpọtụrụ carbon brush maka ọdịnala nke hospital engineering service schedules.

4. ESN Traceability + PICC Insurance + 0%-110% Staged Load Test — Ihe ọkachamara nke ihe ọkachamara maka hospital procurement compliance
Ọ bụla Generator 6ZTAA13-G2 nke Cummins CDC400KVA nwere ESN nke e kọwaa na factory ma bụrụ e test na load-bank na 0%-25%-50%-75%-full prime load na 110% overload bago n'ime ọdịnala. Video nke test na PDF load report bụ isi nke e wepụta na ọdịnala. Warranty bụ nke PICC (People's Insurance Company of China), na-eme ka ihe ọkachamara nke air-freight dị na 3-5 ụbọchị site na global official Cummins service network.
5. 5-Asụsụ Akụkọ + Eziokwu Nke Ihe Nchịkọta + Nke Oge Ọkụrụ / Nke Ntorobịa Nke OEM — Nkwado Pụrụ Iche Nke Ebe Ndị Mmụta Nke Omalicha
Ihe Cummins 400KVA industrial genset CDC400KVA na-akwụsị n’akụkọ nchịkọta nke 150 akụkọ n’asụsụ ise (Beijin, Bekee, Esipanya, Fransi, Rọshia), ndepụta nke ihe ngosi nke ihe na-achịkọta, na CD nke ihe na-achịkọta nke 3D. Jiuan Generator na-enye ihe nchịkọta na ihe nchọpụta. N’ihe kpatara ebe ọkụrụ, ihe nchịkọta nke ọkụ nke isi na ihe nchịkọta nke ihe na-achịkọta na-eme ka ọ dị mma; n’ihe kpatara ebe ntorobịa, ihe nchịkọta nke C5-M bụ ihe nchịkọta nke ọkụrụ nke ọ dị mma.
CDC400KVA 352KW njikere ike generator na-ebute ebe ndị mmụta, ebe ndị mmụta nke ụlọ ọgwụ, na ebe ndị mmụta nke ATS nke ebe ndị mmụta nke oge ọkụrụ:
Jiuan Generator nwere ike ịmepụta ngwa ngwa nke CDC400KVA 400KVA Cummins diesel generator : Otụ ATS (nke ọgụgụ 3-6 sekọnd maka ịgụ agụ), ịmata nke 4G IoT nke na-eme na ntọala, otụ nke na-enye ike maka ọrụ nke otu otu ụlọ ọrụ nke ọgụgụ 1600KVA, otụ nke na-akpọ ọkụ maka ụlọ ọgwụ nke na-eme na obodo nke ọkụrụ dị elu, akpọ nke C5-M maka ịkpọ ọkụ nke ụlọ ọgwụ nke na-eme na obodo nke na-agba ọkụ, otụ nke na-akpọ ọkụ nke 2500L maka ịkpọ ọkụ nke ọgụgụ dị elu, akpọ nke RAL nke na-eme na ụlọ ọgwụ na akpọ nke ụlọ ọgwụ, na 60Hz/440V maka ụdị nke ọgụgụ nke ụlọ ọgwụ nke na-eme na obodo nke na-eme na ụlọ ọgwụ.

G: Kedu ihe bụ ihe kpatara na CDC400KVA 400KVA Cummins diesel generator bụ ihe a na-ekwusi ike maka ụlọ ọgwụ na ụlọ ọgwụ nke isi iyi nke ATS maka ọrụ nke ọgụgụ?
A: 400KVA Cummins diesel generator CDC400KVA nwere ike ịkpata 352KW ESP site na 6ZTAA13-G2 nke a chọrọ maka ọnụ ọgụgụ, ọ na-aga n'ihu n'ime sekondi 3-6 mgbe ọrụ eletrik na-aga n'ihu, na-eme ka ọ dịrị ọkachamara ±1% na THD <3% — ọ na-eme ka ọ dịrị ọkachamara ọrụ eletrik nke ahịa nke MRI, ọrụ ICU ventilators, na ngwaọrụ nke operating theater. Tank nke 950L na-akpata 8+ oru mgbe ọrụ eletrik na-aga n'ihu nke oge dị ogologo.
G: Kedu ihe bụ CDC400KVA 352KW nke a chọrọ maka ọnụ ọgụgụ nke ọrụ eletrik nke na-enye aka na hospital campus nke na-eru okwu na ọrụ eletrik?
A: 352KW njikere ike generator CDC400KVA nke steel canopy nke 3mm na acoustic foam nke na-eru okwu na-eme ka ọ dịrị ≤72dB(A) na 7m — ọ na-eme ka ọ dịrị ọkachamara nke hospital campus, residential zone, na urban commercial district. Nke -25°C ruo +48°C na-eme ka ọ dịrị ọkachamara nke ọrụ eletrik nke ahịa nke ebe dị na Nordic hospitals ruo Middle East na African medical complexes.
G: Kedu ihe ndị na-eme ka CDC400KVA na-eme ka ọ dịrị ọkachamara maka ọnụ ọgụgụ nke hospital?
A: Cummins 400KVA industrial genset CDC400KVA nwere ihe ọrụ nke e gosipụta na factory, video nke ihe ọrụ nke ọdịda 0%-110% na akwụkwọ PDF, akwụkwọ nke ọrụ nke PICC, na akwụkwọ nke CE+ISO8528 maka ịbụ ihe ọrụ nke otu ozi. Akwụkwọ nke ịkpọ ụlọ ọrụ nke 150 pụtara na ise asụsụ na akwụkwọ nke ịkpọ ụlọ ọrụ nke ọdịda na-eme ka ụlọ ọrụ nke hospital nke isi obodo. Ihe ọrụ nke air-freight ga-achọpụta mba niile n’ime 3-5 ụbọchị.

400kVA silent diesel genset nke eji Cummins 6ZTAA13-G2 inline 6-cylinder engine, 50Hz/400V, PF0.8, ezi uche ISO8528. Turbo aftercooled & electronic fuel injection, eji IP23 H-class brushless alternator. Soundproof canopy nke eji n’okpuru nke ọrụ na nke ịkpọ ọkụ, ọdịda ọkachamara na-eme ka ụlọ ọrụ na ebe ọ bụla dị mma na ọrụ nke ọma na ọrụ nke ọma.
otu afọ ma ọ bụ 1000 hours
Nke ọzọ 3 afọ maka Perkins engines;
2 ọdụ maka Stamford S-series alternators
Nkọwa teknụkal nke ọrụ na ngwaọrụ ndị ọzọ nke ọrụ
Gensets nke ị chọrọ: nwere ike ịkpọ, enweghị ihe ịdị iche, nke ị chọrọ ihe ọ bụla
Nke ịrụ ya nke ihe kachasị mkpa na ịkpọ ọnụ ahịa nke ọzọ
Ihe ọ bụla nke e mechara: data centers, mines, ports, infrastructure
24/7 Genset Service Hotline: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Nkọwa ọhụrụ na ọ dị ịrịba ama bụ ihe ọ bụla e nwere ike ịgbanwe.