Ọnọr Ọkachamara
otu afọ ma ọ bụ 1000 hours
CDP357KVA bụ ịdọkọ dị ụtọ nke Jiuan Generator nke 357KVA nke Perkins nke eji eme ihe dị ka ịdọkọ nke ụlọ dị mkpa. E jiri Perkins 1706A-E93TAG1 — engine nke isi asaa, 9.3L nke eji ihe nchịkwa elektronik nke ihe nchịkwa na-eme ihe — eme ya, ịdọkọ ahụ na-eme 285KW/357KVA ISO8528 ESP nke ịdọkọ dị ụtọ ma ọ bụ 245KW/306KVA nke ịdọkọ dị mkpa, na ịdọkọ dị ụtọ nke 16% nke ịdọkọ dị mkpa maka ịdọkọ nke motor nke e ji eme ihe nke ATS. Ihe nchịkwa nke akwụkwọ: 58.5 L/h na ịdọkọ dị ụtọ nke 100%; tank nke akwụkwọ nke 500L maka 8+ oru nke ịdọkọ dị mkpa. EU Stage II / EPA Tier 2; canopy dị ụtọ ≤75dB(A) na 7m; warranty nke 18 ọnwa.
CDP357KVA bụ nke Jiuan Generator 357KVA Perkins diesel generator nke ịmepụta ọrụ kọmpyụtịrị maka ọrụ nke ọrụ dị mkpa na ntọala — ospita, ebe ndị mmadụ na-eme ihe dị ka ụlọ ọkụ dị elu, ebe ndị na-eme ihe dị ka data centres, na ebe ndị na-eme ihe dị ka ụlọ ọrụ ndị na-eme ihe dị ka industrial plants, ọrụ nke grid bụrụ ihe dị ka ọrụ nke ATS na-akpọ ọrụ nke ụlọ niile. E nyere ya ọrụ nke 285KW/357KVA ISO8528 ESP na ntọala na 245KW/306KVA na ntọala nke oge niile, CDP357KVA na-enye ọrụ nke 16% nke ntọala nke oge niile — ọrụ nke kọmpyụtịrị maka ọrụ nke ọrụ nke elevator drives, AHU fans, chiller compressors, na fire pump motors nke na-akpọ ọrụ nke oge niile na ntọala nke ọrụ nke ntọala.
Ihe Perkins 1706A-E93TAG1 genset engine bụ isii-cylinder, anọ-stroke, mmiri-mmachi unit na 9.3L displacement, 115mm × 149mm oghere na strok, na a 16.5:1 mkpakọ ruru. Ọ na-eji electronic elu-nsogbu common-rail mmanụ ụgbọala injection na electronic onye na-achịkwa, na-enye ngwa ngwa ibu-nzọụkwụ omume n'oge ATS transfer ihe. Mmanụ ụgbọala na-eri na 1500 RPM (50Hz): 58.5 L/h na 100% njikere ibu, 42.8 L/h na 75% ibu, 29.3 L/h na 50% ibu. Ịmalite oyi: -15°C n'enweghị enyemaka. EU Stage II / EPA Tier 2 gbaara maka mmejuputa ahia zuru ụwa ọnụ.
The brushless synchronous alternator na-ejide ± 1% voltaji iwu na THD n'okpuru 5% ike àgwà oké mkpa maka ichebe ọgwụ imaging akụrụngwa, IT nkesa akụrụngwa, na BMS ụlọ management usoro si voltaji transients n'oge ibufe. Maka ndị 285KW njikere generator set CDP357KVA, Jiuan Generator nwere ike ịdọpụta Deep Sea DSE7320 maọbu SmartGen HGM6120 controller na AMF auto-start, ATS transfer switching, per-phase voltage na current monitoring, na comprehensive fault protection nke nwere overload, low oil pressure, high coolant temperature, overspeed, na undervoltage. 4G remote monitoring dị iche nwere ike ịdọpụta centralised alarm management n'ime multi-building estate installations.
E nwere ihe atọ nke enclosure formats maka 357KVA emergency power generator CDP357KVA. Ọdịdị a na-emeghe na ntọala ígwè a kwadebere na ihe mgbochi mgbochi vibration dabara adaba maka ụlọ ndị na-emepụta ihe na ụlọ ahịa na ụlọ ọrụ nwere ụlọ ọrụ ụlọ ọrụ. Ihe mkpuchi dị jụụ na-ebelata mkpọtụ radiated ruo ≤75dB ((A) na mita 7 maka ụlọ ọgwụ obodo, ụlọ ọrụ ụlọ akwụkwọ, na ụlọ ọrụ ebe ụkpụrụ mkpọtụ mpaghara na-emetụta. Ọdịdị a na-enye nchebe na-eguzogide ihu igwe maka ụlọ elu, ụlọ ala dị n'èzí, ma ọ bụ nkwụsị ụgbọ ala na-enweghị ụlọ na-emepụta ihe. Igwe mmanụ ụgbọala 500L jikọtara na-akwado awa 8+ nke ọrụ njikere na-enweghị ntinye aka.
Ihe Perkins 1700 TAG1 generator 1706A-E93TAG1 engine bụ nke e jere ya maka 500-hour planned oil service intervals — ihe nke dị mkpa maka generators nke e ji na-akpọgharị na-eme ka ọ dịrị na ngalaba nke eji na-akpọgharị na-eme na mgbe ụbọchị ise na mgbe e nwere ike ịdị n’okpuru nke grid-failure. Ihe ndị dị mma nke Perkins 1706A-E93TAG1 — filter kits, belts, na injectors — nwere ike ịkpọta site na global distribution network nke Perkins na lekwasị 180 countries. Jiuan Generator gụnyere otu otu nke a na ISO 9001 procedures ma gụnyere full-load factory burn-in test b4 ịgụnyere; warranty nke 18-month ma ọ bụ 2,000-hour nwere ike ịkpọta.

| Oke | Uru |
| Mọdelu | CDP357KVA |
| Ihe ndị dị mma nke na-eme ka ọ dị mma | 245KW / 306KVA |
| Ọkụ ọgwụ | 285KW / 357KVA |
| Mọdelụ ọgbụgbọ ejiri | Perkins 1706A-E93TAG1 |
| Cylinders | 6 Inline |
| Ihe nke ịdị ọcha | 9.3L |
| Bore × Stroke | 115mm × 149mm |
| Ụlọ mmiri nchepu | 16.5:1 |
| Sistimu Nkụrụ Nkụ | Nkọwa Elektronik Nke Ọtụtụ Njikọ Nke Ihe Ngosi Nke Ebe Nke Oke Oke |
| Ihe Nkọwa | Nkọwa Nke Turbo, Nkọwa Nke Ebe Nke Air-to-Air Aftercooled |
| Uru Nke Nkọwa | EU Stage II / EPA Tier 2 |
| Nkọwa Nke Oke Oke | -15°C nke enweghị ihe ọ bụla nke ịkpọ |
| Igwè ịrịba ike | 58.5 / 42.8 / 29.3 L/h (100% / 75% / 50% nke ebe a na-eme) |
| Ihe ọmụma ahụ / Ihe ọmụma ahụ | 50Hz / 1500RPM; 60Hz / 1800RPM |
| Phase / Wires | 3-Phase, 4-Wire |
| Igwe Voltage | 415/240V, 400/230V, 380/220V |
| Ọdịnaya nkwere | 0.8 Lagging |
| Nweta | 12V DC Electric Start |
| Ọnụaha | Deep Sea DSE7320 / SmartGen HGM6120 (AMF + ATS) |
| Alternator | Stamford / Leroy-Somer / Tooplinks |
| Isi Insulation | Isi H |
| Ịgụnọ Ịgụnọ | IP23 standard / IP55 nke dị mkpa |
| Nzuzo Dịka | ≤75dB(A) @ 7m (silent canopy) |
| Ụlọ nke ọkụ | 500L integrated base tank |
| Dimensions (L×W×H) | 3800 × 1400 × 2050mm |
| Ibu | 3,400 kg |
| Ọ dị ka ha | ATS Cabinet, Parallel Module, 4G IoT |

1. 16% Standby Headroom Above Prime — Motor Inrush Absorption at ATS Transfer
Ihe 357KVA Perkins diesel generator nke ịmepụta ọrụ CDP357KVA standby rating (285KW/357KVA) bụ 16.3% karịa ya prime rating (245KW/306KVA). Nke a bụ ihe ndị ọzọ na-eme ka o nwere ike ịdị n’okpuru kVA capacity ịkụcha ihe ndị ọzọ nke motor inrush currents nke elevator drives, AHU fans, na fire pump motors mgbe ATS transfer switching — ebe ha nwere ike ịkwaga 5–7× nke ha nwere mgbe ha na-aga — dịka ọmụmaatụ, ọgham na-akwụsị ma ọ bụ overload trip.

2. Common-Rail Electronic Injection — Fast Load-Step Recovery for Full Facility Transfer
Ihe Perkins 1706A-E93TAG1 genset engine uses common-rail high-pressure injection with an electronic governor. Mgbe ATS na-egosipụta full facility load n’ihe kpatara otu, common-rail's sub-cycle fuel delivery response na-akụcha ihe ndị ọzọ nke voltage dip duration na speed recovery time — ihe dị mkpa maka medical equipment na IT infrastructure ebe ha na-akwụsị na supply voltage transients mgbe emergency transfer events.
3. Ihe ndị dị mkpa. DSE7320 AMF Controller N'okpuru 10-abụọ Emergency Auto-Malite
The Deep Sea DSE7320 njikwa na 285KW njikere generator set CDP357KVA na-enyocha voltaji grid na ugboro ugboro n'adabereghị na nke ọ bụla. Mgbe a na-enweghị ike ịwụnye ọkụ, AMF na-amalite na-akpaghị aka ma onye na-emepụta ihe na-enweta ọsọ ọsọ ma mezue nnyefe ATS n'ime sekọnd 10 na-ezute ihe ndị a chọrọ maka oge mmalite ike mberede maka ụlọ ọgwụ, usoro nchekwa ọkụ dị elu, na ebe nrụọrụ UPS na

4. 500L tank Extended Autonomy for Multi-Event Grid Failures (Akwụsị nke Ntanetị Na-eme Ọtụtụ Ihe)
Ihe 357KVA emergency power generator CDP357KVA nwere tank mmanụ ụgbọala 500L. Na 42.8 L/h na 75% njikere ibu (a typical azụmahịa ụlọ mberede ibu larịị), nke a na-ekpuchi ihe dị ka 11.7 awa nke njikere ọrụ kwa ndochi ezu maka a n'abalị-net ọdịda omume enweghị aka refueling aka na saịtị.
5. Oge ọrụ awa 500 Nlekọta dị irè maka ndị na-emepụta ihe na-arụ ọrụ
Ihe Perkins 1700 TAG1 generator oge ọrụ nke awa 500 nke 1706A-E93TAG1 engine pụtara na onye na-emepụta ihe dị mkpa na-arụ ọrụ awa abụọ n'izu na-arụ ọrụ na-arụ ọrụ na-arụ ọrụ na-arụ ọrụ mbụ ya mgbe ihe dị ka afọ ise nke ọrụ dị njikere na-ebelata ụgwọ ọrụ nke ịnọgide na-enwe nnukwu onye na

CDP357KVA 285KW njikere generator set na-eje ozi ndị na-esonụ oké egwu njikere na isi ike ngwa:

Jiuan Generator bụrụ ihe ịmụ ụlọ ọrụ maka CDP357KVA Perkins 1706A-E93TAG1 genset . Ihe ndị dịkwuo n’okpuru bụ: ihe ịdọrọ ike dị ọcha na agba dị iche iche RAL, ihe ịdọrọ ike ATS, ihe ịdọrọ ike nke ịkpata ọgụgụ nke N+1, ihe ịdọrọ ike 4G IoT nke ịkpata ọgụgụ, na ihe ịdọrọ ike nke ọkụ dị ọcha. Ihe niile bụrụ ihe ịmụ ụlọ ọrụ nke Perkins 1706A-E93TAG1 na-eme ka ọ dị ọcha n’ụlọ ọrụ nke ịmụ ụlọ ọrụ.
Aha: Kedu ihe kpatara na ịdọrọ ike nke 250KW nwere ike ịdọrọ ike nke 357KVA?
A: 357KVA Perkins diesel generator nke ịmepụta ọrụ CDP357KVA standby kVA rating accounts for the combined inrush currents of motor loads at ATS transfer onye ọ bụla moto na-ewe 57× na-agba ọsọ ugbu a na mmalite. Ike 357KVA na-enye ohere maka ịba ụba a n'ebughị ibu ma ọ bụ na-agbapụta generator na oge dị oke mkpa nke mbufe mberede.
Ajụjụ: Olee otú ngwa ngwa CDP357KVA na-eru ọrụ voltaji mgbe a grid ọdịda?
A: 357KVA emergency power generator CDP357KVA na DSE7320 AMF controller na-achọpụta ọnwụ nke grid, na-amalite akpaaka-amalite, na-eru ọsọ ọrụ, ma mezue nnyefe ATS n'ime sekọnd 10 na-ezute IEC na ụlọ ọgwụ mberede generator mmalite oge chọrọ maka nchekwa ndụ na akụrụngwa nlekọta dị oke
Ajụjụ: Olee ụdị akwụkwọ ikike na nkwado ọrụ dị?
A: Onye ọ bụla CDP357KVA Perkins 1700 TAG1 generator na-ebu ọnwa 18 ma ọ bụ awa 2,000. A na-echekwa akụkụ ọrụ Perkins 1706A-E93TAG1 mbụ na ndị na-ere ahịa Perkins nyere ikike na ihe karịrị mba 180 maka oge ọrụ 500 awa a na-eme atụmatụ n'oge ndụ ọrụ niile nke generator.
CDP357KVA bụ ịdọkọ dị ụtọ nke Jiuan Generator nke 357KVA nke Perkins nke eji eme ihe dị ka ịdọkọ nke ụlọ dị mkpa. E jiri Perkins 1706A-E93TAG1 — engine nke isi asaa, 9.3L nke eji ihe nchịkwa elektronik nke ihe nchịkwa na-eme ihe — eme ya, ịdọkọ ahụ na-eme 285KW/357KVA ISO8528 ESP nke ịdọkọ dị ụtọ ma ọ bụ 245KW/306KVA nke ịdọkọ dị mkpa, na ịdọkọ dị ụtọ nke 16% nke ịdọkọ dị mkpa maka ịdọkọ nke motor nke e ji eme ihe nke ATS. Ihe nchịkwa nke akwụkwọ: 58.5 L/h na ịdọkọ dị ụtọ nke 100%; tank nke akwụkwọ nke 500L maka 8+ oru nke ịdọkọ dị mkpa. EU Stage II / EPA Tier 2; canopy dị ụtọ ≤75dB(A) na 7m; warranty nke 18 ọnwa.
otu afọ ma ọ bụ 1000 hours
Nke ọzọ 3 afọ maka Perkins engines;
2 ọdụ maka Stamford S-series alternators
Nkọwa teknụkal nke ọrụ na ngwaọrụ ndị ọzọ nke ọrụ
Gensets nke ị chọrọ: nwere ike ịkpọ, enweghị ihe ịdị iche, nke ị chọrọ ihe ọ bụla
Nke ịrụ ya nke ihe kachasị mkpa na ịkpọ ọnụ ahịa nke ọzọ
Ihe ọ bụla nke e mechara: data centers, mines, ports, infrastructure
24/7 Genset Service Hotline: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Nkọwa ọhụrụ na ọ dị ịrịba ama bụ ihe ọ bụla e nwere ike ịgbanwe.