Garantiya Caadiga ah
1 sano ama 1000 saacadood
CDP357KVA waa jeneraasha diesel ee Perkins ee Jiuan ee 357KVA, oo loo isticmaalo si loo xidhiidho nidaamka daryeelka ah ee qaybta la xidhiidho. Waa la xidhiidhaa naqshada Perkins 1706A-E93TAG1 — waxaana u qabowdo shan iyo saddex cilinder, 9.3L, oo leh injeekshin elektroonik ee common-rail — taasoo ka saaraya 285KW/357KVA ISO8528 ESP (kulliye) iyo 245KW/306KVA (dhexe), iyo 16% kharashka kuwa ku jira (standby headroom) ka badan kharashka dhexe (prime) si ay ugu xidhiidho xoolaha (motor inrush) marka la guurinayo ATS. Xoolaha: 58.5 L/h marka la xidhiidho 100% kharashka kuwa ku jira (standby load); tanka 500L oo ka dhigan 8+ saacado (autonomy). EU Stage II / EPA Tier 2; canopy silent ≤75dB(A) marka la xidhiidho 7m; waranqa 18 maalmood.
CDP357KVA waa jenereshinka Jiuan jenereshin diesel ee Perkins ee 357KVA waa la xusay oo ku saabsan talada ku saabsan ee xafiiska muhiimka ah — mashruuca hospitaalka, banaanka siyaasadda sare, markaarka daata, iyo mashruuca industriyada, taasoo ku saabsan in khatarka dhaqanka ay ugu dhowaan doonayaan ATS ku saabsan oo dhan ee xafiiska. Waa la qoray inuu yahay 285KW/357KVA ISO8528 ESP ku saabsan iyo 245KW/306KVA ku saabsan, CDP357KVA wuxuu siinayaa inrush headroom ee 16% ku saabsan ka dib markii uu ku saabsan — isku dayn oo loo isticmaalo inuu siinayo inrush current ee elevator drives, AHU fans, chiller compressors, iyo fire pump motors oo la isticmaalo mar walba markii uu ku saabsan.
Waa Jenereshin kaabka Perkins 1706A-E93TAG1 injinkeeda waa injin six-cylinder, four-stroke, oo la xidhiyay biyo, oo leh 9.3L volume, oo leh 115mm × 149mm qurux iyo dhaqo, iyo 16.5:1 ratio ee ku saabsan. Wuxu isticmaala injin elektronik ee ku saabsan koor-riil ee jiritaanka sare, iyo goobta elektronik ee ku saabsan, oo soo saaraya xagga xaqiijinta xaqiijinta ka badan marka ay la isticmaalo ATS. Xaqiijinta xaqiijinta 1500 RPM (50Hz): 58.5 L/saac marka ay la isticmaalo 100% marka la isticmaalo, 42.8 L/saac marka la isticmaalo 75%, 29.3 L/saac marka la isticmaalo 50%. Xaqiijinta gudaha: -15°C marka la isticmaalo. EU Stage II / EPA Tier 2 ayaa la isticmaalo marka la isticmaalo gobolka ah.
Altenaterka ee leh macluumaadka sida ah ee leh ±1% ku saabsan xagga voltajka, iyo THD ka yar marka 5% — xagga xaqiijinta xaqiijinta waxyaabaha ugu muhiimsan ee ku saabsan qorshaha tibbiyada, xagga serverka IT, iyo xagga BMS ee ku saabsan xagga xaqiijinta xaqiijinta marka la isticmaalo xagga xaqiijinta xaqiijinta. Marka kooxka xaqiijinta 285KW CDP357KVA, Jiuan Generator wuxuu ku xidhan yahay Deep Sea DSE7320 ama SmartGen HGM6120 controller, oo leh AMF auto-start, ATS transfer switching, monitoring per-phase voltage iyo current, iyo comprehensive fault protection ee ku saabsan overload, low oil pressure, high coolant temperature, overspeed, iyo undervoltage. Optional 4G remote monitoring wuxuu kaa heli karaa centralised alarm management kaalinta multi-building estate installations.
Ee tigaalada sida saddex ee la isticmaalo waa la heli karaa 357KVA emergency power generator CDP357KVA. Qaabka qaab-dhismeedka furan ee leh saldhig bir ah oo xoojiyay iyo taageerada anti-vibration waxay ku habboon tahay qolalka matoorrada gaarka ah ee dhismayaasha ganacsiga iyo xarumaha leh qolalka warshadaha qaab dhismeedka. Qalabka aadka u aamusan wuxuu hoos u dhigaa buuqyada la shubay ilaa ≤75dB ((A) 7 mitir oo loogu talagalay isbitaalada magaalooyinka, xarumaha jaamacadda, iyo dhismayaasha xafiisyada halkaas oo la adeegsado heerarka buuqyada maxalliga ah. Qaabka weelka ayaa bixiya ilaalinta cimilada ee saqafka, dhirta dibedda ee dabaqa hoose, ama dejinta dekedda baabuurta ee aan lahayn dhisme matoor go'an. Baakada shidaalka ee 500L waxay taageertaa 8+ saacadood oo hawlgal ah oo aan lahayn shidaal gacmeed.
Waa Perkins 1700 TAG1 matoor mootarka 1706A-E93TAG1 wuxuu leeyahay 500 saacado ah oo dhisay in la guurin doono xoolaha, taas oo ku saabsan qof kasta oo ku nool in ay ugu yaraan isticmaal isticmaalka qofka ah ee ka dhacaya in ay isku dayaan mar walba iyo hadalada xoolaha ee ka dhacaya marka jiritaanka kuwa aan lahayn. Qoraallada asli ah ee Perkins 1706A-E93TAG1 — qoraallo, beltada, iyo injektorrada — waxaa la heli karaa midigga ugu weyn ee Perkins ee ku yaal 180 bilood. Jiuan Generator wuxuu dhisaa ilmaha kasta oo ku yaal taliyadda ISO 9001 iyo wuxuu sameeyaa tijaabo la xidhiidh karaa oo dhan-joogta ah ee gudaha ka hor inta ay ugu soo celin doonaan; warqadka caawimaadka 18 maalmood ama 2,000 saacadood ayaa la siiyaa.

| Tusaale | Qiimo |
| Model | CDP357KVA |
| PRIME POWER | 245KW / 306KVA |
| STANDBY POWER | 285KW / 357KVA |
| Modelka badbaadaha | Perkins 1706A-E93TAG1 |
| Cylinders | 6 Inline |
| Dib u dejinta | 9.3L |
| Bore × Stroke | 115mm × 149mm |
| Qaybta dabaca | 16.5:1 |
| Sistema ee Dhawaan | Injekshanka Elektronik ee Kaadis-kaaloo ee Guurka Sare |
| Iibbi | Wax ku dhaqaaqay, Ka soo xiran oo ka soo xirin kooni |
| Xawaaraha Emission | EU Darajadda II / EPA Darajadda 2 |
| Dhacdaya Dheerka Sare | -15°C la isku dayn karin |
| Kharashka Gudaha | 58.5 / 42.8 / 29.3 L/sa (100% / 75% / 50% ku nool) |
| Tirada khadka / Tirada guurka | 50Hz / 1500RPM; 60Hz / 1800RPM |
| Khadda / Xariirka | 3-Xaas, 4-Xariir |
| Kharajka Vooltijka | 415/240V, 400/230V, 380/220V |
| Qeybta awoodda | 0.8 Ka wada xidhiidh |
| Dhalinyarada | dhacdo Elektrik 12V DC |
| Xakamaynta | Deep Sea DSE7320 / SmartGen HGM6120 (AMF + ATS) |
| ALTERNATOR | Stamford / Leroy-Somer / Tooplinks |
| Nooca Dhexeeya | Nooca H |
| Qaybta Xanaano | IP23 siyaasad / IP55 siyaasad ka mid ah |
| Tasooxadda Ciise | ≤75dB(A) @ 7m (qurux kuma jirin) |
| Xaaf gaadiid | kuulka 500L ee ku xidhan |
| Dhamaan (D×R×W) | 3800 × 1400 × 2050mm |
| Miisaanka | 3,400kg |
| Xogga ah | Kabinitka ATS, Madoobka Iyadoo La Taliyay, 4G IoT |

1. 16% Khaas-ka Dib-u-eegidda Kuwa La Istaagayaa — Xidhiidhka Qabashada Motor-ka Kuwa La Istaagayaa Marka Laga Badaliyo ATS
Waa jenereshin diesel ee Perkins ee 357KVA Qaabka CDP357KVA ee la Istaagayaa (285KW/357KVA) waa 16.3% ka badan kuwa la istaagayaa (245KW/306KVA). Tani waa khaas-ka kuwa la istaagayaa ee leh qodobada kVA ee loo baahan yahay inay xidhiidhdaan qodobada inrush ee motors-ka kuwa la istaagayaa, fans-ka AHU, iyo motors-ka pump-ka dhulka marka laga badaliyo ATS — taasoo ku jira inay ku jirto 5–7× qodobada run-ka ah ee ay ku jirto marka la bilaabo — balse ma aqoon doonin in ay xidhiidhdaan frequency-ka ama in ay ku jirto overload trip.

2. Isku-dhafan-ka Elektronik ee Common-Rail — Xidhiidhka Qabashada Sarreeyey ee Qodobada Load-ka Si Loogu Talagalay Dhammaan Dhamaan-ka Baddalka
Waa Jenereshin kaabka Perkins 1706A-E93TAG1 engine wuxuu isticmaala common-rail ee isku-dhafan-ka gacan-gacan oo leh electronic governor. Marka ATS u baddalo dhammaan dhamaan-ka load-ka waxaa lagu sameeyo qodobada sarreeyey ee isku-dhafan-ka common-rail ee ku jira sub-cycle ee qodobada fuel ee ay xidhiidhdaan xidhiidhka voltage dip ee dhammaan-ka dhammaan-ka iyo xidhiidhka speed recovery time — tani waa wax muhiim ah oo ku saabsan tibixinta iyo infrastrukturka IT ee ay ku jirto xidhiidhka voltage transients ee ku saabsan marka ay ku jirto baddalka emergency.
3. Controller-ka DSE7320 AMF — Auto-Start ee Emergency ee Ka Yar Marka 10 Second
Kontrolerka Deep Sea DSE7320 ee xeerada ka baxa kooxka xaqiijinta 285KW CDP357KVA ayaa raadaya jirka iyo taarikha ee xeerada ka baxa mar kasta. Marka jirka ka baxa, AMF ayaa dhammaan ku daray in la dhisayo, oo jirka ayaa gaadhi doona xiriirka iyo ay ku dhammaan karaan ATS ee ku dhammaan karaan 10 sekundood — waxay la xiriiraan waqtiga la xiriiraan in la dhisayo jirka ee qalabka nabadgelyo, nidaamka caafimaadka hoos u jeedda, iyo jirka ee ku dhex jira UPS ee ku dhex jira data centre.

4. Tankiga 500L — Xiriirka la xiriiraan oo ka badan ee ku saabsan jirka ka baxa mar kasta
Waa 357KVA emergency power generator CDP357KVA wuxuu leeyahay tankiga 500L ee ku dhex jira. Marka uu noqon 42.8 L/h marka uu noqon 75% ee jirka la xiriiraan (waxaana ku saabsan qaabka jirka la xiriiraan ee degmada), tanu wuxuu ku saabsan 11.7 saacadood ee jirka la xiriiraan per fill — waa guul ahaan ku saabsan jirka ka baxa oo ka dhawaan gudaha, la maqan in la dhisayo jirka ka baxa oo aan la dhisin.
5. Xiriirka 500-saacadood ee la xiriiraan — La xiriiraan oo fudud ee jirka la xiriiraan
Waa Perkins 1700 TAG1 matoor waqtiga adeegga 500-saac ee mashiinka 1706A-E93TAG1 wuxuu ka dhigan yahay in matoorka dayactirka ee xarunta muhiimka ah ee shaqeynaya 2 saacadood usbuucii jimicsiyada tijaabada uu gaaro adeeggiisa ugu horreeya ee la qorsheeyay ka dib qiyaastii 5 sano oo ah

CDP357KVA kooxka xaqiijinta 285KW waxay u adeegtaa codsiyada soo socda ee heegan iyo awoodda ugu badan:

Jiuan Generator wuxuu sammaynayaa habka OEM ee CDP357KVA Jenereshin kaabka Perkins 1706A-E93TAG1 waxyaabaha la heli karaa waa: guriyaha aan lahayn saaxiib ah oo la xiriiray RAL, guriyaha ATS, moduulka u dhaqanka parallel ee si loo isticmaalo N+1, 4G IoT ee si loo eegiyo dhexeeya, iyo tanka aad u weyn ee xoolo. Dhammaan waxyaabaha ay la sameeyeen markii la isticmaalo Perkins 1706A-E93TAG1 iyo ay la qaataan tijaabo la xiriiray dhammaan xoolo ka dib markii la soo diriyo.
Su’aal: Maxay sababta u ahayd in xoolo ku jira 250KW ay u baahan yihiin xoolo ku jira 357KVA?
Jawaab:jenereshin diesel ee Perkins ee 357KVA Qaabka CDP357KVA ee kVA ee ku dhaqmaynayaa waxay ku saabsataa xagga ka dhacaya ee qaybaha motor-ka ee la isticmaalo ATS — marka laga bilaabo, motor-kii hadda ay la isticmaalo 5–7× xagga ka dhacaya ee la isticmaalo mararka badan. Qaabka 357KVA wuxuu siinayaa fursad dheer oo aan la jiro ama la qaato gennyar-ka marka ugu waacdaya ee la isticmaalo marka la isticmaalo nidaamka aasaasiga ah.
Su’aal: CDP357KVA waa inaad ka yaryahay inuu helo xagga ka dhacaya ee la isticmaalo kadib marka la dhaqmaynayaa nidaamka grid?
Jawaab:357KVA emergency power generator CDP357KVA leh controllerka DSE7320 AMF wuxuu helaa dhaqmaynta grid, bilaabaa inuu siiyo isku dayn, helaa xagga ka dhacaya ee la isticmaalo, iyo dhammaan inuu dhaqmaynayo ATS ka dib marka 10 sekundood — waxay la xiriiraan IEC iyo xagga ka dhacaya ee gennyar-ka aasaasiga ah ee hooyga iyo xagga ka dhacaya ee la isticmaalo nidaamka aasaasiga ah ee ku saabsataa nolosha iyo xagga ka dhacaya ee la isticmaalo nidaamka aasaasiga ah.
Su’aal: Waa maxay warqadaha garan iyo taageerada la isticmaalo?
Jawaab: CDP357KVA kasta Perkins 1700 TAG1 matoor wuxuu leeyahay warqad garan ee 18 maalmood ama 2,000 saacadood. Qaybaha asluubta Perkins 1706A-E93TAG1 ayaa la isticmaalo marka la isticmaalo 500 saacadood ee la isticmaalo marka la isticmaalo nidaamka gennyar-ka, iyo ay la isticmaalo marka la isticmaalo 180 qoys oo la isticmaalo marka la isticmaalo nidaamka Perkins-authorized dealers.
CDP357KVA waa jeneraasha diesel ee Perkins ee Jiuan ee 357KVA, oo loo isticmaalo si loo xidhiidho nidaamka daryeelka ah ee qaybta la xidhiidho. Waa la xidhiidhaa naqshada Perkins 1706A-E93TAG1 — waxaana u qabowdo shan iyo saddex cilinder, 9.3L, oo leh injeekshin elektroonik ee common-rail — taasoo ka saaraya 285KW/357KVA ISO8528 ESP (kulliye) iyo 245KW/306KVA (dhexe), iyo 16% kharashka kuwa ku jira (standby headroom) ka badan kharashka dhexe (prime) si ay ugu xidhiidho xoolaha (motor inrush) marka la guurinayo ATS. Xoolaha: 58.5 L/h marka la xidhiidho 100% kharashka kuwa ku jira (standby load); tanka 500L oo ka dhigan 8+ saacado (autonomy). EU Stage II / EPA Tier 2; canopy silent ≤75dB(A) marka la xidhiidho 7m; waranqa 18 maalmood.
1 sano ama 1000 saacadood
Ugu yar 3 sano oo ku saabsan injinada Perkins;
2 sano oo ku saabsan alternaterada Stamford S-series
Caawimaad teknikada ah iyo shabakadda soo saarita qaybaha la isticmaalo
Waa maxayna oo JIUAN generator set ku siiyaa — ka hor ama ka dib marka ay ku iman doonaan bandarkaaga.
Garantiyadda dhammaan ee 2 sano ama 2,000 saacado (ee ka horreysa), la xaqiijiyey in lagu dhisay PICC — waxay siinaysaa kaalayaasha ka tirsan dalka kale ammaan oo dhan ku saabsan kulli qof.
Isdhaafka gudahooda ee dhulka ka mid ah — waxyaalaha muhiimka ah ee garantiyadda ayaa soo noqon doona dalka oo dhan 3 ilaa 5 maalmood, waxay ka saaraysaa xaaladaha aan la isku dayn karin oo ka yaryar.
Quruxa ku saabsan dhulka ayaa isticmaala dhulka oo ku saabsan dhulka, koonfureedka oo leh koonfur weyn iyo insulaashanka oo la jiro nafas.
Kulli qof ayaa cusub oo leh ESN oo kala duwan, oo la xaqiijiyey. Kulli jeneraatoor ayaa la isku daynayaa isku daynta dhammaan iyo isku daynta ka badan ilaa markii la soo diray.
Qaybaha loo isticmaalo waddooyinka qalad leh, waddooyinka xagga badweynada iyo waddooyinka la isku dayo karaa waxa ka mid ah foomaha loo isticmaalo si loo xusuuso, xusuuska iyo foomaha loo isticmaalo si loo dhaqan gacanta.
Taswiirka iyo taajabka sertifikeedka loo isticmaalo si loo guurto qofka ku jira maalinta iyo maalinta ku jira bandarkaaga waxa uu ku caawin doonaa in ay ugu yar tahay dhammaan waddooyinka ka soo baxa masraxaaga ilaa bandarkaaga.
Genset-ka la xiriira: mid ka yar, mid ka dhaqaaqo, mid ka xiriira qaybta dhinaca
Talada guurka iyo talada ka soo baxa
Qoraal ka Dhexeeya: marka data, meexaha, bandhigga, iyo xafiiska
genset Service Hotline 24/7: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Jawaab badan oo xasiloon iyo ku saabsan ayaa la isticmaali karaa.